Catalog excerpts

Patients first performance Philips BrightView SPECT specifications The BrightView SPECT system is a “purely Philips” nuclear medicine product with a wide range of innovations to help healthcare providers manage patient care. Designed from the ground up to put patients first, the system is easy to use, fast, and reliable with exceptional image quality. Surprisingly compact given its capabilities, BrightView is a fully featured variable angle camera differentiated by exclusive CloseUp technologies – enabling increased resolution by reducing the distance between its advanced detector electronics and the patient. The system’s customizable yet automated acquisition capabilities make it excellent for streamlining workflow today, and also provide the means for leveraging the molecular imaging agents of tomorrow. Fully supported by the resources of Philips services, BrightView SPECT is designed to be easily upgradeable to future configur
Open the catalog to page 1
Camera characteristics JETStream acquisition Gantry dimensions 221.5 cm H x 198 cm W x 174 cm D Weight (without collimators) 3,862 lbs (1,755 kg) Power requirements 30A 208-240V, 50/60 Hz single phase Total heat dissipation (typical) 800 Watts/hr. Gantry aperture 38" (96.5 cm) Caudal-cephalic tilt +/- 15" (not available on BrightView Value) Pallet type Aluminum Scan length + UFOV 78.7" + 16" (200 cm + 40.6 cm) Scan speed 1 - 190 cm/min. Speed of rotation 5.0 rpm (relative 180°) Scan diameter (with LEGP) <4"- 31.5" (<10.2 cm - 80 cm) ECT manual rotation speeds 0.5...
Open the catalog to page 2
* Astonish - Reconstruction method with 2 iterations and 32 subsets. Values subject to change. ** Planar Astonish - calculated values 1. Specifications are NEMA NUI - 2001 method of measurement with a 20% energy window. Values to be used for acceptance testing. 2. Represents calculated values derived from measured 3.8" (9.5 mm) crystal values and/or limited sampling 3/4" (19.1 mm) crystal values. Values not to be used for acceptance testing. 3. Measured using a pixel size of 9.3 mm. Note: Specifications subject to change.
Open the catalog to page 3
* Astonish - Reconstruction method with 2 iterations and 32 subsets. Values subject to change. ** Planar Astonish - calculated values 1. Specifications are N EMA NUI - 2001 method of measurement with a 20% energy window. Values to be used for acceptance testing. 2. Same test conditions as N EMA specifications. Represents average factory test values. Values not to be used for acceptance testing. 3. Measured using a pixel size of 9.3 mm. Note: Specifications subject to change.
Open the catalog to page 4
BrightView camera and collimator specifications Type Hole Size Septa Length Construction Septa Penetration Sensitivity Spatial Resolution Shape (mm) (mm) (mm) I (%) (keV) I Cpm/pCi System(6) Cast Cast (1) +Sensitivity is for Tc-99m with 20% window, 9.5 mm thick crystal. (2) Gallium-67 with 20% window 93 keV, 184 keV, 300 keV photo peaks. (4) The pinhole collimator is rated for 364 keV and has 25.4 cm F.O.V. at the crystal. (5) Relative sensitivity is for Tc-99m at 10 cm from the pinhole. (6) For 9.5 mm thick crystal. Note: Sensitivity numbers are NEMA Class Standards and are ±7%....
Open the catalog to page 5
BrightView preferred room layout 186" (15'-6") 4724 mm 5.48' 139 mm Processing station Customer provided desktop. Philips provided computer, monitor and keyboard. Patient table Operator position Wall-mount acquisition terminal Collimator exchanger Patient access Calibration source holder Environmental requirements for general equipment locations Throughout the SPECT suite, the HVAC system must maintain the temperature between 60 degrees F (16 degrees C) to 75 degrees F (24 degrees C) with less than 10 degrees F (5 degrees C) variation per hour. Humidity must be between 20% to 75%. These...
Open the catalog to page 6All Philips Healthcare catalogs and technical brochures
-
DreamMapper
2 Pages
-
DFM100
6 Pages
-
Trilogy 202
4 Pages
-
Sparq - DS
4 Pages
-
Pinnacle³ Dynamic Planning
8 Pages
-
dStream HeadNeckSpine coil
2 Pages
-
EPIQ 7
20 Pages
-
Compatibility table
4 Pages
-
Vereos Digital PET/CT brochure
21 Pages
-
MobileDiagnost wDR
2 Pages
-
PerforMax
2 Pages
-
Philips TPI
6 Pages
-
ST80i stress-testing system
8 Pages
-
Philips CardioMD IV
12 Pages
-
Diamond Select
2 Pages
-
Cardiology supplies guide
4 Pages
-
BV Pulsera
7 Pages
-
Pinnacle3
6 Pages
-
Azurion accessories
20 Pages
-
fat-free imaging performance
2 Pages
-
Critical Values
2 Pages
-
Freedom of view
3 Pages
-
HeartStart MRx
12 Pages
-
PageWriter TC70
2 Pages
-
Patients first performance
6 Pages
-
BrightView X and XCT
6 Pages
-
Ingenuity TF PET/CT
20 Pages
-
IntelliVue to Go
8 Pages
-
MicroDose SI Product
16 Pages
-
HRC Mask Catalog - US
32 Pages
-
V60
4 Pages
-
Vereos PET/CT
8 Pages
-
MobileDiagnost Opta
4 Pages
-
Philips ProGrade Product
4 Pages
-
Access Dual CT
8 Pages
-
EasyDiagnost Eleva DRF
17 Pages
-
MDE 3D-RX Brochure
6 Pages
-
MDE Brochure
20 Pages
-
Juno DRF Product Overview
4 Pages
-
Philips InnerCool STx+
2 Pages
-
The time has come
24 Pages
Archived catalogs
-
MobileDiagnost wDR_2010
4 Pages