1. Catalogs
  2. Polarseal Tapes & Conversions Ltd
  3. 3M™ Medical Hook Fastener 7335
video corpo

3M™ Medical Hook Fastener 7335

3M™ Medical Hook Fastener 7335

Product catalog summary
Product Overview
Product number 7335, formerly known as MSX-6559A, is the 3M Low Profile Hook with Adhesive. It is not intended for wound management, but incidental skin contact is possible. The product is deemed safe for its intended use based on toxicity test data and ingredient assessment.
Biocompatibility Studies
The adhesive used in this product has undergone several biocompatibility studies:
  • In Vitro Cytotoxicity (Agar Overlay): Conducted following the protocol by Guess, W. L. et al., with results showing 0.0/0.0, indicating no cytotoxicity.
  • Acute Primary Skin Irritation in Albino Rabbits: Conducted following the Draize protocol, with results showing 0.0/8.0, indicating no skin irritation.
Compliance and Testing Standards
These tests comply with ISO 10993 Part-1 "Biological Evaluation of Medical Devices" as required by the FDA. All laboratory testing adhered to the FDA Good Laboratory Practices Regulation of 1978.
Customer Responsibility
It is the responsibility of customers to determine the final suitability of the product for their specific applications.
See more

Catalog excerpts

3M™ Medical Hook Fastener 7335-1

Medical Specialties 3M Health Care PRODUCT CLINICAL DATA SUMMARY Product number 7335 [formerly MSX-6559A] 3M Low Profile Hook with Adhesive Effective: September 2008 This product is not intended for wound management but incidental skin contact is possible. Based on the low potential for any significant skin contact, an evaluation of existing toxicity test data and an assessment of the ingredients, Low Profile Hook 7335 is safe for its intended use. The adhesive used on this product has been subjected to the following biocompatibility studies. In Vitro Cytotoxicity (Agar Overlay) Protocol reference: Guess, W. L. et al; "Agar Diffusion Method for Toxicity Screening of Plastics on Cultured Cell Monolayers" J. Pharm. Sci. 54:15451547 (1965).(HRFE 00915) Results: 0.0/0.0 Acute Primary Skin Irritation in Albino Rabbits Protocol reference: Draize: Appraisal of the Safety of Chemicals in Food, Drugs and Cosmetics (1965). Published by the Editorial Committee of the Association of Food and Drug Officials of the United States. (HRFE 00915.) Results: 0.0/8.0 These tests are in accordance with the ISO 10993 Part-1 "Biological Evaluation of Medical Devices", as put forth by the FDA. All laboratory testing was conducted in accordance with the FDA Good Laboratory Practices Regulation of 1978. It is the responsibility of our customers to determine the final suitability of our products for their application.

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.