1. Catalogs
  2. Porvair Sciences Ltd
  3. MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR

MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR

MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR
1 / 12 PagesView full catalog

MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR

Product catalog summary
Introduction
Porvair Sciences presents the Microlute™ range, aimed at enhancing sample preparation with improved reliability and reproducibility. The brochure emphasizes the innovative hybrid technology that addresses common issues in sample preparation workflows, thereby improving chromatographic performance.
Microlute™ Hybrid Technology
This section explains the unique composite filter technology that incorporates chromatographic active media within porous plastic structures. The hybrid design ensures consistent flow rates, maximizes contaminant removal, and enhances analyte recovery, leading to improved sensitivity and integrity of analytical methods.
Microlute™ PLR
Specialized for phospholipid removal, Microlute™ PLR achieves over 99% removal efficiency and greater than 90% analyte recovery. It offers market-leading reproducibility with less than 4% RSD, ensuring high confidence in results.
Microlute™ CP
Microlute™ CP enhances SPE performance with a hybrid structure that improves analyte extraction and recovery. It offers consistent results with less than 4% RSD, suitable for high-throughput studies. The CP range includes reversed phase and ion exchange options for diverse applications.
Microlute™ CP RP - Reversed Phase for SPE
This section describes the reversed phase method using polymeric DVB for retaining neutral and non-ionisable compounds. It outlines the sample preparation steps, including conditioning, equilibration, loading, washing, and elution.
Strong and Weak Ion Exchange
The brochure covers the ion exchange range, including strong and weak cation and anion exchange options. Each type is designed for specific analyte retention based on charge and pH, using the hybrid technology for high reproducibility.
Microlute™ SLE
Microlute™ SLE uses diatomaceous earth for supported liquid extraction, allowing efficient analyte recovery from biological samples. It supports high throughput and cleaner sample preparation with reduced manual handling.
Microlute™ PPP
The Protein Precipitation Plate (PPP) efficiently removes proteins from plasma and serum using a dual filter system. It is designed for high-throughput processing and minimal protein contamination, suitable for automated workflows.
Additional Products
The brochure also mentions filter plates, vacuum manifold and collection plates, and glass chromatography vials and closures, providing a comprehensive range of sample preparation solutions.
Overview
The document provides detailed information on filtration plates, vacuum manifolds, chromatography vials, and related accessories offered by Porvair Sciences. These products are designed for various laboratory applications including filtration, sample preparation, and chromatography.
Filtration Plates
Porvair Sciences offers a range of filter plates optimized for applications such as cell harvesting, DNA separations, and sample clean-up. The plates are available in 48-, 96-, and 384-well formats with materials like glass fibre, nylon, PVDF, and polyethylene. Well volumes range from 350 μl to 7.5 ml.
Vacuum Manifolds
The Microlute™ vacuum manifold is made from acrylic and acetal polymer, designed for use with SBS/ANSI specification filter plates. It features a valve controller for vacuum adjustments and is compatible with various collection plate volumes. The Universal Robotic Manifold is suitable for automation and compatible with different brands of filter plates.
Chromatography Vials and Closures
The document lists various vials such as R.A.M.™ Vials, Snap Seal™ Vials, and Big Mouth Vials, designed for use with robotic arm autosamplers. These vials are available in clear or amber borosilicate glass with different sealing options like Poly Crimp™ Seal and Snap Top Cap™.
Product Specifications
Detailed specifications for each product are provided, including product numbers, descriptions, formats, and pack quantities. The document also includes ordering information for various Microlute™ products and accessories.
Key Features
The products are designed for high reproducibility, ease of use, and compatibility with automation systems. They offer features like low protein binding, long drip directors, and chemical resistance.
See more

Catalog excerpts

MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-1

M I C R O L U T E ™ S A M P L E P R E PA R AT I O N RANGE BROC HURE

 Open the catalog to page 1
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-2

Porvair Sciences introduces Microlute™, the innovative range of sample preparation products designed and manufactured to deliver uncompromised chromatographic performance with a whole new level of reliability and reproducibility. With over 30 years’ experience in manufacturing porous plastics and microplates for chromatography applications, these unique capabilities have led to the development of the Microlute™ hybrid technology, a solid active filter that is set to redefine the standards of sample preparation workflows. At Porvair Sciences we recognise the importance of time, quality and cleanliness...

 Open the catalog to page 2
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-3

Microlute™ Hybrid Technology Porvair Sciences expertise in porous plastics manufacturing has led to the development a unique composite filter, a porous plastic structure containing chromatographic active media immobilised within evenly distributed pores. This hybrid technology is designed to offer greater control over flow rates throughout sample preparation methods. Consistent flow of liquids through the active media maximises removal of contaminants and recovery of analytes with greater reproducibility. The Microlute™ hybrid technology enhances the sensitivity and integrity of analytical methods...

 Open the catalog to page 3
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-4

Microlute™ PLR Phospholipids are a ubiquitous class of amphiphilic molecules found in all living organisms as a major component of cell membranes. Although essential to cells, removal of phospholipids from biological samples is a fundamental sample preparation step to eliminate a major source of ion suppression and obtain true analyte signals for analysis. Utilising the strengths of the hybrid technology, Microlute™ PLR effectively removes all classes of phospholipids and maximises analyte recovery with market-leading reproducibility. Market Leading Reproducibility < 4 % RSD for Higher Confidence...

 Open the catalog to page 4
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-5

Microlute™ CP takes SPE to a new level of performance by enhancing the reproducibility of analyte extraction and recovery from biological, environmental and chemical samples. Unlike traditional loose-filled SPE methods, Microlute™ CP uses a hybrid structure, a solid interconnected network of evenly distributed pores combined with the retentive media. This design enhances the flow-through of samples to maximise interactions between analytes and the solid phase to deliver a reproducible SPE method that excels in performance, cleanliness and sensitivity. Phases: Reversed Phase (RP), Strong Cation...

 Open the catalog to page 5
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-6

Microlute™ CP reversed phase (RP) plates and cartridges contain immobilised polymeric DVB (divinyl-benzene) within its structure for retention of neutral and non-ionisable compounds. The stationary phase allows analytes to be retained via hydrophobic interactions and polar contaminants are simply removed by washing with a polar solvent such as water. Depending on the desired analysis, retained analytes can be gradually eluted off in fractions with increasingly non-polar solvents or flushed all together from the phase with a strong organic wash. Microlute™ is an ideal starting point for many applications...

 Open the catalog to page 6
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-7

Ion exchange cartridges and plates retain, and separate analytes based on their charge or its ionisation behaviour with respect to pH or ionic buffer strength. The Microlute CP ion exchange range covers both anion and cation in both weak and strong forms to cover the full range of sample and analyte types. All forms use the innovative Microlute CP hybrid technology to offer the highest available reproducibility levels available, without compromising the chromatography. Sample matrix: Low ionic strength aqueous sample matrix Cationic exchange: Positively charged with ionisable analytes Anion exchange:...

 Open the catalog to page 7
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-8

Easily extract a wide range of acidic, basic and neutral analytes from a range of biological or aqueous samples with a superior method of liquid extraction, supported liquid extraction (SLE). Microlute™ SLE 96 well plates and cartridges use selectively sourced diatomaceous earth (DE) as the solid support to maximise absorption of the aqueous solutions to allow simpler recovery of analytes from samples with greater reproducibility. Analysis: UHPLC, HPLC, GC, LCMS, GCMS Applications: Forensics, pharmaceutical, drug discovery and clinical Formats: 96 well plates and cartridges Weight: Max Load Volume...

 Open the catalog to page 8
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-9

The Microlute™ Protein Precipitation Plate (PPP) is designed to efficiently precipitate proteins from plasma and serum. Using the crash method, proteins are precipitated or ‘crashed’ out with acetonitrile and filtered. The 96 well plate efficiently handles processing up to 96 samples at once and ensure minimal protein contamination during injection into chromatographic systems. Analysis: UHPLC, HPLC, GC, LCMS, GCMS Formats: 96 well plates The Microlute™ PPP plate uses a novel dual filter to efficiently removal proteins without leakage of samples. The super hydrophobic filter prevents samples...

 Open the catalog to page 9
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-10

Vacuum manifolds are used to draw liquid through a filter or SPE plate into either a waste tray or a collection plate. The application of vacuum increases the speed at which samples can be collected. The Microlute™ vacuum manifold from Porvair Sciences is precision machined from crystal clear acrylic (top plate) and acetal polymer (plenum chamber). The acrylic top plate allows visual access to the plenum chamber for checking progress of the separation process. • Designed to take most filter plates manufactured to the SBS/ANSI specification with long drip directors • Also designed so that SPE...

 Open the catalog to page 10
MICROLUTE™ SAMPLE PREPARATION RANGE BROCHUR-11

Glass vials are essential to any chromatography workflow. We offer a wide range of vials, seals, inserts and caps to suit routine and high throughput sample analyses. Designed and manufactured by JG Finneran, all vials are compatible with robotic arm autosamplers. R.A.M. vials are designed specifically to work with robotic arm autosamplers that have a crimp style height with the convenience of a screw thread configuration. Choose from clear or amber Type I borosilicate glass. 12 x 32 mm 9 mm threads, borosilicate glass. Product Number Big Mouth Inserts ig mouth limited volume inserts are designed...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.