General Overview
The Powerex Medical Refrigerated Air Treatment Center is engineered to supply medical breathing air for hospitals and medical institutions, adhering to NFPA 99 standards for Level 1 breathing air.
Air Purification Package
The package is designed according to NFPA 99 specifications and includes dual refrigerated air dryers, dual filter and regulator banks with sample ports, Dew Point and CO Monitors with alarms, and bypass piping. The piping materials include brass, stainless steel, or type K copper, all cleaned for medical air use. Components are mounted, piped, and wired to a common skid.
Refrigerated Air Dryers
These non-cycling, direct expansion dryers use R-134 A refrigerant and feature a hot gas bypass system for consistent temperature. They include copper tube heat exchangers, power and high temperature lights, a suction pressure gauge, an internal 3-micron filter/separator, and a timed electric condensate drain.
Filtration / PRV Valves
A duplex set of filters and regulators with block-and-bypass valves allows servicing without air flow disruption. Each bank includes a coalescing filter with differential pressure indicators, an activated carbon filter, and an adjustable pressure regulator with gauge. A 75 psig safety valve and sample ports for CO and Dew point monitors are provided.
Dew Point Monitor
The integrated hygrometer features an LCD display and high dewpoint alarm with remote monitoring capabilities. The sensor is installed downstream of the pressure regulator assembly and includes auto calibration for accuracy.
Carbon Monoxide Monitor
The CO monitor displays CO concentrations and provides audible and visual high CO alarms, set at 10 ppm per NFPA99. It includes dry contacts for remote monitoring.
Dimensions and Specifications
The document lists dimensions and specifications for various models of medical refrigerated dryers, including SCFM, dew point, power requirements, and unit weight. Each dryer provides 100% backup, and the SCFM should match the compressor's SCFM with one compressor in reserve as per NFPA 99.
See more

Catalog excerpts

Medical Air Dryer System - Refrigerated-1

The Powerex Medical Refrigerated Air Treatment Center is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing air. The air purification package shall be sized in conformance with NFPA 99 specifications and consist of the following: Dual refrigerated air dryers, dual filter and regulator banks with sample ports, Dew Point and CO Monitors with alarms, and all bypass piping. Piping to be brass, stainless, or type K copper, and cleaned for medical air use. All components shall be mounted piped and wired to a common skid. The refrigerated air dryers are non-cycling, direct expansion type, using R-134 A refrigerant (CFC free). A hot gas by- pass system maintains a consistent temperature at all load conditions. Heat exchangers are made of copper tube construction and fully insulated. Dryers shall have power on and high temperature lights, suction pressure gage, internal 3-micron filter/separator with stainless steel bowl, and timed electric condensate drain. The system-integrated hygrometer shall be equipped with an LCD dewpoint display and high dewpoint alarm with dry contacts for remote monitoring. The dew point sensor (probe) shall be installed so that the monitored airflow is downstream of the pressure regulator assembly. The sensor shall include an auto calibration feature to ensure the accuracy of the dewpoint measurement. CARBON MONOXIDE MONITOR The carbon monoxide (CO) monitor is provided in an enclosure with LCD display of CO concentrations. The monitor shall continuously display the CO content of the discharge air and shall provide audible and visual high CO alarms. High alarm is set at 10 ppm per NFPA99. Dry contacts are provided for remote monitoring of the high CO A duplex set of filters and regulators shall be provided with block-and-bypass valves, such that one bank can be serviced without disrupting the flow of air to the system. Each bank shall have a coalescing filter, equipped with differential pressure indicators, an activated carbon filter, and an adjustable pressure regulator with gauge. A 75 psig safety valve is provided at the final outlet along with sample ports

 Open the catalog to page 1
Medical Air Dryer System - Refrigerated-2

Medical Refrigerated Dryers Rev. 4/13/11 DIMENSIONS DIM. DIM. DIM. MODEL A B C Inlet Outlet MDR0258 57" 36" 41" 1/2" 1/2" MDR0358 57" 36" 41" 1/2" 3/4" MDR0558 57" 36" 41" 3/4" 1" MDR0708 57" 36" 41" 1" 1.5" MDR1008 57" 36" 41" 1" 1.5" 1 5" MDR1508 57" 36" 41" 1.5" 1.5" Top View 24” Minimum Clearance for ease of Maintenance for ease of Maintenance Medical Refrigerated Dryers MODEL MDR0258 MDR0358 MDR0558 MDR0708 MDR1008 MDR1508 SCFM @100 PSIG 25 35 55 70 100 150 Pow er Dew per Dryer Point @ in Watts 50 PSIG 205 31oF 253 28oF 410 27oF 589 26oF 930 28oF 1300 27oF Voltage* 115 V 208-230 V 115 V...