1. Catalogs
  2. Precision Medical
  3. EasyPulse Flow Conserving Flowmeter

EasyPulse Flow Conserving Flowmeter

EasyPulse Flow Conserving Flowmeter

EasyPulse Flow Conserving Flowmeter

Product catalog summary
Overview: The EasyPulseFlow conserver/flowmeter is designed for use with low-pressure systems (50-55 psi) and offers both Continuous Flow and Pulse Dose modes. It aims to reduce oxygen consumption and waste, thereby saving costs on medical oxygen.
Specifications: The device measures 7.9 inches in height, 1.9 inches in width, and 2.5 inches in length, weighing 10.4 oz. It operates within an inlet pressure range of 50-55 psi and offers Pulse Dose settings from 1 to 5, with a conserving ratio of up to 5.7:1. The Continuous Flow range is 0-15 lpm, with a maximum flush flow of 24 lpm. It requires a 7-foot adult single lumen nasal cannula and functions effectively up to 35 breaths per minute.
Clinical Evaluation: A trial conducted at Presbyterian Intercommunity Hospital evaluated the EasyPulseFlow's clinical and economic feasibility. Over 90 days, 57% of patients successfully used the Pulse Dose mode, while 36% required the Continuous Flow mode due to shallow or mouth breathing. The trial resulted in an 8% decrease in oxygen purchases despite increased patient admissions and a rise in oxygen costs.
Conclusion: The EasyPulseFlow flowmeter effectively reduces oxygen consumption and costs, even amidst increased hospital admissions and rising oxygen prices. The trial demonstrated its potential for significant savings in a hospital setting.
See more

Catalog excerpts

EasyPulse Flow Conserving Flowmeter-1

The Future of Oxygen Therapy Made in

 Open the catalog to page 1
EasyPulse Flow Conserving Flowmeter-2

EasyPulse Flow Conserver /Flowmeter REDUCE: Oxygen Consumption ELIMINATE: Wasted Oxygen SAVE: Money on Medical Oxygen The EasyPulseFlow conserver/flowmeter is designed to be used with low pressure systems (50-55 psi). It consists of a Thorpe tube flowmeter combined with a conserving module. The clinician is able to choose between Continuous Flow mode or Pulse Dose mode. In the Continuous Flow mode the flowmeter operates the same as a traditional Thorpe tube flowmeter capable of delivering metered flows from 0 to 15 lpm and up to 24 lpm at flush flow. The outlet connection is the same as a traditional...

 Open the catalog to page 2
EasyPulse Flow Conserving Flowmeter-3

Add PTO behind part number for Power Take-Off Specifications are subject to change without prior notice.

 Open the catalog to page 3
EasyPulse Flow Conserving Flowmeter-4

“ Presbyterian Intercommunity rlffl Hospital EVALUATION OF A HOSPITAL OXYGEN CONSERVING FLOWMETER Hal Herlong RRT Objective: To determine the clinical and economic feasibility of incorporating a new oxygen conserving flowmeter into PIH EVALUATION OF A HOSPITAL OXYGEN CONSERVING FLOWMETER Hal Herlong RRT Background: Presbyterian Intercommunity Hospital is an acute care 440 bed facility. The economy of today has continued to add additional pressure on providers to discover ways to conserve economically while continuing to provide high standards of care. We decided to engage in a trial of the...

 Open the catalog to page 4

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.