Pasive matresses
2Pages

{{requestButtons}}

Catalog excerpts

Pasive matresses - 1

PASSIVE ANTI-DECUBITUS MATTRESSES Extra | Single-sided sandwich anti-decubitus mattress designed for bariatric patients | Suitable for healthcare, nursing and home care for patients with higher weight | Mattresses suitable for patients with low to medium risk of developing pressure ulcers (stage I and II) | The lower support layer made of PUR foam provides high load capacity and long-term durability of the mattress | Lateral prunings of the lower layer improve air circulation and also divide the mattress into 3 zones according to stiffness | The top layer of the mattress made of cold HR foam gives the mattress optimum stiffness and provides excellent weight distribution of the patient | Standard mattress thickness 14 cm | Suitable for patients weighing up to 250 kg VISCO foam water resistence Effective solution for people particularly vulnerable to the risk of developing pressure ulcers. Unique type of polyurethane foam with open cellular structure, which changes its hardness depending on temperature. The foam softens when in contact with body heat and flexibly adapts to the anatomy of the body. Due to the effect of slow recovery of the foam, the mattress evenly distributes pressure on the human body which has a positive effect on blood circulation, improves sleep quality and relieves back pain. At the same time it stabilizes the body in an optimal position for sleeping - the user rotates less during the night which contributes to a peaceful sleep. VISCO foam The cover SAFR with its properties is particularly suitable for use in healthcare and nursing sector. This removable cover is made of polyester fabric with coating of ecologically pure polyurethane. The advantages of this material are mainly durability, flexibility in the longitudinal and transverse direction, breathability, water resistance and durability. An important feature is the resistance to the effects of urine and blood. The cover is anti-allergic and anti-bacterial, it can be treated by conventional disinfectants and is washable up to 95°C. These features make it suitable for departments with a high turnover of patients. The cover can be customized: | SAFR stitched / SAFR seamless (welded mattress edges) | With drip lip / no drip lip (zipper cover) | With a zipper in L-shape, U-shape or all around Unique solution for a peaceful and healthy sleep. 3D mesh is made up of a dense network of vertically arranged polyester fibers. Thanks to them an air cushion is created between the patient's body and the mattress core. It ensures perfect ventilation and cooling effect, which is very pleasant especially at higher temperatures. The used material improves flexibility of the mattress and prolongs its life. The main advantage of latex is its point elasticity. This means that under a load only the part of the material which is being exerted to force deforms and surrounding area remains unchanged. Thanks to this it perfectly follows the curves of the human body. At the same time it provides excellent breathability, helps permeability and circulation of air in the material and thus prevents moisture retention. It is created by a special process of foaming the polyurethane mass, by which an open cell structure is formed in the material. Thanks to this tmaterial provides excellent breathability and elasticity. The mattress then can optimally follow the shape of the human body. Another advantage of PUR is a wide range of possible rigidity and durability. Material fully respecting the current trends of healthy sleep. Modern high quality type of polyurethane foam produced without using formaldehydes and other harmful substances. HR (High Resilience) foam is characterized by an open structure of the material, high elasticity and breathability (greater than conventional PUR foam). It flexibly adapts to the human body. It also excels in significant strength, permanent stability (preventing unwanted distortion), ventilation (air permeability perfectly dissipates heat and reduces the occurrence of mites) and long life. Special VisCoool® foam is a material with properties that fully correspond to the conventional VISCO foam and moreover can absorb human warmth. This helps to an intensive cooling effect for the duration of sleep, open structure of the foam ensures moisture wicking and significant breathability of the material. The basic material for the production of bonded polyurethane foam is PUR foam. RE foam is created by bonding of polyurethane foams of different densities crushed into small pieces. RE foam gives the mattress the required rigidity and higher load capacity. Stage of pressure ulcers Loading capacity Number of anatomic zones Reinforced edge Double-sided / single-sided molded PUR foam + RE foam + molded PUR foam cold HR foam with pruning cold HR foam with pruning + reinforced edges cold HR foam with pruning + reinforced edges + 3D mesh PUR foam with pruning + cold HR foam cold HR foam + molded cold HR foam + latex gel molded cold HR foam + VISCO foam Soft Flex cold HR foam with pruning + VISCO foam (unglued core) cold HR foam + molded cold HR foam + Viscoool® foam TECHNICAL SPECIFICATIONS Cotton cover with a modern tread design in fresh greenish color. It is pleasant to touch and helps reduce the disruptive effects of static electricity, which can have a negative effect on our body during sleep. Popular variant of knitted fabric with Aloe Vera finish enhances the softness and smoothness of the upholstery fabric. The cover is easily removable and thanks to the possibility of washing up to 60°C it ensures absolute hygiene and antibacterial properties of the mattress and the entire bed. Collection of passive anti-decubitus mattresses of PROMA REHA has been designed with maximum regard to prevention of pressure ulcers, patient safety and perfect hygiene. Anti-decubitus mattresses have been developed based on measurements of distribution of pressure forces acting on the patient by using a special sensor pad. All mattresses are designed to spread the patient's weight optimally over a larger area and thus reduce the pressure exerted on the tissue. The pressure values at the predilection areas of an ideal decubitus mattress should not exceed the long-term critical point of 32 mmHg (4.27 kPa). Thus, the pressure at which a closure of small capillaries in the tissue occurs. Reaching the optimal properties of passive mattresses is achieved through the use of high quality foams, mattress core pruning techniques and a special flexible coating which helps to eliminate other factors of pressure ulcers development, such as moisture or shearing and frictional forces. PROMA REHA, s.r.o., Riegrova 342, 552 03 Ceska Skalice, Czech Republic, EU, tel.: +420 491 112 233, info@promareha.cz

Open the catalog to page 1

All PROMA REHA catalogs and technical brochures

  1. PRIMO PREMIO

    2 Pages

  2. Invent

    2 Pages

  3. Hestia

    2 Pages

  4. Grano

    2 Pages

  5. Geneo

    2 Pages

  6. Tables

    2 Pages

  7. Hestia

    2 Pages

  8. INVENT

    2 Pages

  9. VISION

    2 Pages

  10. TITAN

    2 Pages

  11. Image katalog

    24 Pages

  12. ACCESSORIES

    2 Pages