TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine
1 / 56Pages

Catalog excerpts

TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 1

PRODUCT CATALOG World leaders in the design and manufacture of quality medical imaging phantoms

Open the catalog to page 1
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 2

About Pure Imaging Phantoms are one of the world leaders in the design and manufacture of quality medical imaging phantoms. MISSION Pure Imaging Phantoms aims to provide the highest value medical imaging phantoms for quality control in the market and work alongside specialists to create these. WORKING WITH US We work with professionals in the medical imaging field to produce cutting-edge and innovative phantoms for the international market. If you have an idea and would like to collaborate with us to develop and manufacture it then please contact us.

Open the catalog to page 2
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 4

Fluoroscopy & Radiography This is a routine medical imaging test phantom which is used daily to evaluate the imaging performance of fluoroscopic systems. Evaluate: · Brightness and contrast adjustment: Cu for High light & Pb for low light details Circular Geometry check: scanning linearity Imaging contrast: 18 low-contrast and high-contrast details with contrast values from 0.9 to 16.7% @70kVp 1mm Cu, 8mm diameter. Resolution: 0.5 to 5.0 Line pairs/mm Geometry and collimation check markings Variable designs with different FOV sizes are available upon request. Comes with: · 1mm high purity...

Open the catalog to page 4
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 5

Fluoroscopy & Radiography This is a simple and efficient-to-use routine medical imaging test phantom which is used daily to evaluate the imaging performance of digital fluoroscopic systems. You can simply check the grey-scale, count the number of contrast details and resolve the line patterns. If these numbers ever avert from the norm then this may indicate deterioration of image quality in your fluoroscopic imaging system. Evaluates: · Brightness and contrast adjustment: Cu for High light & Pb for low light details Geometry check: scanning linearity Imaging contrast: 18 low-contrast and...

Open the catalog to page 5
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 6

Fluoroscopy & Radiography This is a simple and efficient-to-use routine medical imaging test phantom which is used daily to evaluate the imaging performance of digital and conventional fluoroscopic systems. You can simply check the baseline number. If these numbers ever avert from the norm then this may indicate deterioration of image quality in your fluoroscopic imaging system. This should be used with a Copper attenuator which can be bought separately. Evaluates: · Beam alignment and collimation Spatial resolution Dynamic range (Different thickness Cu steps each with a central 4.0mm...

Open the catalog to page 6
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 7

Fluoroscopy & Radiography A routine medical imaging test phantom which is used daily to evaluate the imaging performance of digital radiography systems. You can simply follow the baseline of results established. If this baseline ever averts from the norm then this may indicate deterioration of image quality in your imaging system. This phantom should be used with PMMA and Copper attenuators or Aluminium attenuators which are available to buy separately. Evaluates: · Collimation and beam alignment Position and size of radiation field Radiopaque cassette size alignment markers Spatial...

Open the catalog to page 7
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 8

Fluoroscopy & Radiography A routine medical imaging test phantom which is used daily to evaluate the imaging performance of fluoroscopic systems. You can simply check the grey-scale, count the number of contrast details and resolve the line patterns. Evaluates: · Brightness and contrast adjustment: High-light & low-light details Circular Geometry check: scanning linearity Imaging contrast: 17 low-contrast and high-contrast details with contrast values from 0.2 to 7.5% @70kVp for low contrast and 3.9 to 95.4% for high contrast 1mm Cu, 11mm diameter. Resolution: 0.5 to 14.3 Line pairs/mm...

Open the catalog to page 8
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 9

Fluoroscopy & Radiography This is a simple and efficient-to-use routine medical imaging test phantom which is used daily to evaluate the imaging performance of fluoroscopic systems. You can simply resolve the mesh pattern details. If these numbers ever avert from the norm then this may indicate deterioration of image quality in your fluoroscopic imaging system. Specification: · Resolution meshes available: 16 to 60 lines/inch, 30 to 100 lines/inch & 60 to 150 lines/inch Comes with: · Detailed user manual Robust carrying case Complies with: ·

Open the catalog to page 9
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 10

Fluoroscopy & Radiography This is a simple and efficient-to-use routine medical imaging test phantom which is used daily to evaluate the imaging performance of radiography and fluoroscopic systems. You can simply follow the baseline of results established. If this baseline ever averts from the norm then this may indicate deterioration of image quality in your imaging system. This phantom is primarily used for beam centring and alignment. Evaluates: · Collimation and beam alignment Central beam positioning determination Low contrast resolution details (6, 15mm diameter details) Variable...

Open the catalog to page 10
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 11

Fluoroscopy & Radiography This is a simple and efficient-to-use routine medical imaging test phantom which is used daily to evaluate the imaging performance of fluoroscopic systems. The phantom is designed in accordance to Center for Devices and Radiological Health (CDRH) specifications. Evaluates: · High and low-contrast resolution (Disc of aluminium with 8 low contrast disks and copper meshes for high contrast). Resolution meshes available: 16 to 60 lines/inch, 30 to 100 lines/inch & 60 to 150 lines/inch Comes with: · Copper, Lead and Aluminium filters Detailed user manual Robust carrying...

Open the catalog to page 11
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 12

PURE.PMMA Stack Fluoroscopy & Radiography A set of polished PMMA plates for testing AEC of radiography imaging systems. Manufactured with the highest quality diamond polished PMMA. Specification: · We can make any dimension or thickness of PMMA upon request. Comes with: · Robust carrying case Complies with: ·

Open the catalog to page 12
TEST PHANTOM_Fluoroscopy_Radiography_Mammography_CT_Nuclear_Medicine - 13

Aluminium attenuators Fluoroscopy & Radiography This is a routine medical imaging test phantom which is used daily to evaluate the imaging Patient equivalent attenuator made from Aluminium which can be used for evaluating the performance of fluoroscopic systems. performance of general radiography imaging systems. Evaluate: Specification: ·· Brightness and contrast adjustment: Cu for x 21mm & Pb for low light details Dimensions of Aluminium block: 153 x 153 High light Circular Geometry check: scanningx 175 x 2mm Dimensions of mounting plate: 168 linearity · Imaging contrast: 18 low-contrast...

Open the catalog to page 13