Vitra 810, Glaucoma treatment
1 /6Pages

Vitra 810, Glaucoma treatment

Vitra 810, Glaucoma treatment
1 /6Pages

Catalog excerpts

Vitra 810, Glaucoma treatment-2

SubLiminal® Cyclophotocoagulation SubCyclo® is a new nondestructive laser procedure for the treatment of glaucoma. Based on the transcleral cyclophotocoagulation principle, it relies on the 810 nm SubLiminal® stimulation of the ciliary body, producing the aqueous humour, and the uveoscleral pathway, secondary route of the aqueous outflow. This procedure can be performed thanks to the combined use of the Quantel Medical Vitra™ 810 laser and the Quantel Medical SubCyclo® probe. Laser treatment is delivered by moving the tip of the probe in a continuous sliding motion: Tip of the probe in contact...

 Open the catalog to page 2
Vitra 810, Glaucoma treatment-3

SubCyclo® Clinical Data A new treatment for advanced and end-stage glaucoma Primary angle glaucoma, primary angle closure glaucoma, pseudo-exfoliation, neovascular glaucoma, glaucoma associated with steroid uses, uveitis and after keratoplasty surgery (2,3) An efficient treatment procedure leading to a reduction in the medication regimen (2,4) Significant and persistent reduction in IOP at 12 months (2) Mean number of medication (2) - Before treatment: 3.4 ± 1.7 - After treatment: 2.9 ± 1.6 30% decrease from baseline and less than 21 mmHg SubCyclo® preserves the structures of the ciliary body...

 Open the catalog to page 3
Vitra 810, Glaucoma treatment-4

Vitra™ 810: A versatile laser One single laser probe: Two glaucoma treatments Quantel Medical SubCyclo® laser probe is uniquely designed with a removable footplate allowing implementing both SubLiminal® and thermal treatment procedures. One laser: Two clinical applications Although designed for the SubCyclo® laser therapy, Vitra™ 810 can also be used to perform all the usual 810 nm glaucoma and retina treatments. When used in Retina treatment mode, Vitra™ 810 can be connected to various delivery systems, such as slit lamp, LIO, operating microscope and laser

 Open the catalog to page 4
Vitra 810, Glaucoma treatment-6

TECHNICAL SPECIFICATIONS wrfw a-ionrti User Source: Wavelength: Power at tissue up to; Pulse duration; Aiming beam; Repeat interval; Emission modes Power requiremtuts: user diode technology £10 nm o.i - az-o.3- o.s- o.ts Single, repeat, continuous painting Subliminal Mode (duly cycle from b9t to 30%} 10 (H) x 19.5 (W}*30 (D) cm BIBLIOGRAPHY 1- Agrawal P, Martin KR. Ciliary body position variability in glaucoma patients assessed by scleral transillumination. Eye. 2008;22:1499-1503. 2- Benhatchi N, Bensmail D, Lachkar Y. Benefits ofSubCyclo laser therapy guided by high frequency ultrasound biomicroscopy...