WORKSTATION FOR PIPETTES CALIBRATION - 2 Pages

Add to MyMedicalExpo favorites
WORKSTATION FOR PIPETTES CALIBRATION

Catalog excerpts

WORKSTATION FOR PIPETTES CALIBRATION release date 01-06-2015 In order to ensure measurement traceability, meet all the requirements resulting from supervision over measuring equipment and to facilitate the process of pipettes calibration RADWAG recommends effective and ergonomic solution for calibrating automatic pipettes conducted by a user - complete workstation for pipettes calibration. Application: 1. Calibration of automatic pipettes from 1µl to 10ml: —with fixed volume —with adjustable volume. 2. Weighing of samples with maximum capacity up to 21g and accuracy d=1µg (in standard weighing chamber - pan ø 26mm). Unit contents: —table for calibration —microbalance MYA 21.4Y.P —anti-vibration table —probe for temperature, humidity and pressure measurement —probe for water temperature measurement —sink for used water —armrests —LCD monitor —PC with pre-installed software PIPETTES RADWAG —power supply —keyboard and mouse —container for used water * The pipettes and other small accessories are not included in the unit content The integral part of the workstation constitutes a microbalance MYA 21.4Y.P series (with a special calibration vessel and a evaporation ring) and a dedicated PC software “PIPETTES" by Radwag. MEASURING MODULE: 1. Microbalance MYA 21.4Y.P: An analytical balance designed especially for the purpose of pipettes calibration. The weighing chamber contains an evapouration ring minimizing the errors resulting from liquid evapouration process. Basic parameters: · Max: 21 g · d = 1 µg · repeatability: 1,5 µg · linearity: ±7 µg For more details and full technical data see instrument's product folder. 2. Weighing table: The weighing table is designed with special emphasis on reliable, fast, comfortable and ergonomic operation. Workstation’s external construction is independent on internally mounted anti-vibration table featuring a stone table top. The design eliminates possible vibrations and considerably shortens

 Open the catalog to page 1

AMBIENT CONDITIONS MODULE: 1. Probes for measurement of water temperature, relative humidity and atmospheric pressure. Parameters: ■ air temperature: d = 0,1°C ■ relative humidity: d = 1 % ■ atmospheric pressure: d = 1 hPa 2. Probe for measurement of distilled water temperature. Parameters: ■ water temperature: d = 0,1 °C 1. PC computer with LCD monitor, keyboard and mouse 2. PIPETTES computer software conducting all the computation related to the procedure of pipettes calibration using gravimetric method in accordance with international standard ISO 8655-6. The program allows to generate...

 Open the catalog to page 2

All RADWAG Balances & Scales catalogs and technical brochures

  1. THBR 2.0 System

    4 Pages

  2. USB FREE LINK

    2 Pages

  3. PIPETTES

    4 Pages

  4. Mass Comparators

    20 Pages

  5. Album Radwag

    242 Pages

  6. PUE5 TERMINAL

    2 Pages

  7. HY10 TERMINAL

    2 Pages

  8. HRP PLATFORMS

    2 Pages

  9. CHECKWEIGHERS

    16 Pages

  10. WPY SCALES

    4 Pages

  11. PERSONAL SCALES

    1 Pages

  12. BABY SCALES

    1 Pages

  13. BED SCALES

    1 Pages

  14. PALLET SCALES

    1 Pages

  15. BEAM SCALES

    2 Pages

  16. BEAM SCALES

    2 Pages

  17. RAMP SCALES

    2 Pages

  18. CHAIR SCALES

    1 Pages

  19. BED SCALES

    1 Pages

  20. TABLE FOR SCALE

    2 Pages

  21. PUE HY TERMINAL

    2 Pages

  22. TERMINALS PUE 5

    2 Pages

  23. DIGITAL MODULES

    1 Pages

  24. Checkweigher

    16 Pages

  25. movable range

    2 Pages

  26. PS 2100.R1.CT

    2 Pages

  27. Product catalogue

    160 Pages

  28. PERSONAL SCALES

    1 Pages