Group: Randox
Catalog excerpts
RX IMOLA A fully automated clinical chemistry analyser A COMBINED THROUGHPUT OF 560 TESTS PER HOUR
Open the catalog to page 1THE RX IMOLA DELIVERS HIGH QUALITY TESTING FOR RESULTS YOU CAN TRUST
Open the catalog to page 2SYSTEM OVERVIEW TEST MENU ORDERING INFORMATION RANDOX - A GLOBAL DIAGNOSTIC SOLUTIONS PROVIDER
Open the catalog to page 3TEST MENU & CONSOLIDATION Our extensive dedicated test menu comprises routine chemistries, lipids, antioxidants, cardiac and diabetes testing allowing laboratories to expand their testing capabilities while reducing additional TEST MENU costs associated with sending samples to be tested externally. Direct, on-board, HbA1c testing capabilities provide many time saving benefits in the laboratory. As there is no incubation step required HbA1c tests can be performed immediately, performing QC and Calibration checks quicker as only one assay is required, and offline calculations are not needed...
Open the catalog to page 4FLEXIBILITY & VERSATILITY 12 wavelengths generated via diffraction grating (340-800nm) ensure a multitude of chemistries are possible on one system. The RX imola is capable of running monochromatic, bi-chromatic, endpoint, kinetic, ISE, sample blanking and reagent blanking assays. A cooled reagent carousel, with 60 positions, allows on-board storage without compromising stability. UNRIVALLED PERFORMANCE 90 Pyrex® cuvettes with cuvette check function ensures only clean and viable reaction vessels are used. 5 speed mixing arms eliminate foaming and ensure adequate mixing of latex enhanced...
Open the catalog to page 5SYSTEM OVERVIEW 60 reagent positions for 20ml, 50ml and 100ml bottles, all cooled between 8 -15°C. Our smart reagent inventory management system with automatic barcode functionality ensures instant recognition of reagents. Randox offers a wide range of dedicated, high performing and unique reagents. Dual 5 speed rotating stirrers rinsed with purified water. The option of different mixing speeds ensure each reagent and sample are at optimum viscosity to enable accurate and precise measurement. An 8 stage washing process with acid, alkali and pure water wash steps ensures cuvettes are...
Open the catalog to page 6SAMPLE CAROUSEL The emergency loading port allows run interruption for STAT sample processing. 72 positions are contained within the outer ring of the carousel for normal and STAT samples with 20 positions available in the inner ring for QC and calibrators. Barcode sample identification ensures accurate matching of patient identification to specimen. With 90 permanent Pyrex® cuvettes, the RX imola reduces downtime and ongoing consumable costs associated with changing disposable or semi-disposable cuvettes. Permanent cuvettes offer a lifespan of up to 5 years ensuring stability and accuracy...
Open the catalog to page 7THE RX SERIES TEST MENU CLINICAL AUTOIMMUNE: Complement Component 3 Complement Component 4 CRP CRP Full Range (0.3-160mg/l) CRP High Sensitivity IgA IgE IgG IgM Rheumatoid Factor BASIC METABOLIC PROFILE: Calcium CO2 Total Chloride Creatinine Glucose Potassium Sodium Urea BONE PROFILE: Alkaline Phosphatase Calcium Phosphorus Total Protein CARDIAC: Cholesterol CK-MB CK-NAC CRP CRP Full Range (0.3 -160mg/l) CRP High Sensitivity Digoxin Direct HDL Cholesterol Direct LDL Cholesterol H -FABP Homocysteine Lipoprotein (a) Myoglobin sdLDL Triglycerides COMPREHENSIVE METABOLIC PROFILE: Albumin...
Open the catalog to page 8VETERINARY Albumin Alkaline phosphatase ALT (GPT) Aldolase Ammonia Amylase AST (GOT) Bile acids Bilirubin Calcium Chloride Cholesterol Cholinesterase (Butyryl) CK-NAC CO2 Total Copper Creatinine Canine CRP CRP Fructosamine Gamma - GT GLDH Glucose Glycerol HDL2/3-C Iron (UIBC) Lactate Lactate dehydrogenase LDL Lipase Magnesium NEFA (Non-esterified fatty acids) Phosphorus (Inorganic) Phenobarbitol Phenytoin Valproic Acid Potassium Ranbut (Hydroxybutyrate) Ransel (Glutathione peroxidase) Ransod (Superoxide dismutase) Sodium Total Protein Triglycerides Urea Uric Acid Urinary protein Zinc...
Open the catalog to page 9SOFTWARE The RX imola incorporates Windows® 10 based software. This intuitive software is easy for users to navigate, enhancing productivity requiring minimal training. The main screen links to a number of tabs including: Quality Control, Parameter, Calibration and Maintenance, allowing for simple access to information and straight forward selection of the operations required. Secure remote diagnostics saves money and time by allowing access to expert technical and applications staff anytime, anywhere. LIMS (Laboratory Information Management System) connectivity is easily achievable via...
Open the catalog to page 10This screen indicates the number of tests and time left until Less than 5 minutes daily maintenance is required. completion. STAT samples may be added without disturbing existing runs. QUALITY CONTROL The QC screen generates Levey - Jennings charts and calibration The software displays the current valid calibration for each curves allowing a visual performance assessment plus easy assay installed, the reagent blank absorbance and the calibration identification of QC errors and emerging trends. QC multi check interval. There are 6 calibration models available: rules can be applied to ensure...
Open the catalog to page 11FEATURES AT A GLANCE Providing excellence in clinical chemistry, the RX imola fully automated system combines robust hardware and intuitive software with a wide range of unique and innovative features. Liquid level sensor, crash, Versatile reagent carousel bubble and clot detection of just 18 litres per hour with 60 cooled positions Unique loading hatch allows 90 permanent Pyrex® cuvettes with Universal sample carousel with emergency samples to be analysed innovative cuvette check functionality 72 positions and 20 cooled control quickly and easily at any time which optimises analyser...
Open the catalog to page 12ORDERING & CUSTOMER SUPPORT In choosing to purchase the RX imola from Randox you are partnering with a company that has over 35 years’ experience in the IVD industry and clinical chemistry analyser placements in over 120 countries worldwide. Customers needs vary and Randox sales staff and distributor partners will work with your laboratory to create a bespoke package to suit your requirements. Randox Laboratories provide customers with an unrivalled technical support service. ORDERING INFORMATION For more information contact your local representative, or email us at: theRXseries@randox.com
Open the catalog to page 13All Randox Laboratories catalogs and technical brochures
-
VeraSTAT-V
16 Pages
-
VERASTAT
16 Pages
-
Endocrine Array
4 Pages
-
Cerebral Arrays
4 Pages
-
Thyroid Arrays
4 Pages
-
Respiratory Multiplex Array
8 Pages
-
LT107 Evidence Investigator
32 Pages
-
LT253 Molecular Diagnostics
20 Pages
-
LT367 FH Array Brochure
4 Pages
-
Evidence Evolution
28 Pages
-
Evidence
16 Pages
-
2018 Product List
84 Pages
-
The role of EQA in QC
8 Pages
-
Basic QC Stastics
8 Pages
-
Commutability Guide
4 Pages
-
How to measure uncertainty
8 Pages
-
ISO 15189 Educational Guide
8 Pages
-
Troubleshooting QC Errors
8 Pages
-
RX Monaco
20 Pages
-
RX Daytona Plus
20 Pages
-
RX misano
20 Pages
-
Qnostics
52 Pages
-
RX SERIES ANALYSER OVERVIEW
24 Pages
-
RX modena
20 Pages
-
ACUSERA
101 Pages
-
LT033 RIQAS Explained
56 Pages
-
sdLDL-C
4 Pages
-
Adiponectin LT519
28 Pages
-
Specific Proteins
40 Pages
-
Linearity sets
12 Pages
-
Antioxidants
16 Pages
-
Cardiology & Lipid Testing
28 Pages
-
Diabetes Portfolio
28 Pages
-
Reagents Brochure
72 Pages
-
Total Bile Acids
4 Pages
-
VIVALYTIC
30 Pages
-
RANDOX DISCOVERY
36 Pages
-
HbA1c
2 Pages
-
Preparing QC
1 Pages
-
Point of Care Testing
12 Pages
-
LT394 Using QC Multirules
1 Pages
-
Guide to running QC
1 Pages
-
Tumour Marker Arrays
4 Pages
-
Which QC is the Right QC
8 Pages
-
How often is right for QC
6 Pages
-
Cardiac Risk Multiplex Array
4 Pages
-
LT241 Metabolic Array MAY15
8 Pages
-
KRAS / BRAF / PIK3CA Array*
4 Pages
-
Custom Arrays for Biochip
12 Pages
-
LT169 Cardiac Array
4 Pages
-
Rx Daytona
16 Pages
Archived catalogs
-
RIQAS Explained
36 Pages
-
Acusera
132 Pages
-
Metabolic Syndrome Arrays
8 Pages
-
STI Multiplex Array
8 Pages
-
Molecular Testing
16 Pages
-
Evidence Investigator
20 Pages
-
Fertility Array
4 Pages
-
Evidence Investigator
16 Pages
-
Evidence
16 Pages