Group: Randox
Catalog excerpts
RX MODENA A Fully Automated Clinical Chemistry Analyser CAPABLE OF PERFORMING UP TO 1200 TESTS PER HOUR
Open the catalog to page 1THE RX MODENA IS A FULLY AUTOMATED, CLINICAL CHEMISTRY ANALYSER, THAT PROMISES TO REVOLUTIONISE YOUR LABORATORY
Open the catalog to page 2SYSTEM OVERVIEW TEST MENU ORDERING INFORMATION RANDOX - A GLOBAL DIAGNOSTIC SOLUTIONS PROVIDER
Open the catalog to page 3BENEFITS The RX modena is a high throughput, floor standing clinical chemistry analyser, capable of performing up to 1200 tests per hour including ISE. With the ever expansive, unrivalled RX series test menu, the RX modena offers a winning combination for large multi-disciplinary laboratories. The icon based, interactive touch-screen technology offers an easy to use solution. The RX modena presents a new class of efficiency without compromising on the precision, reliability and accuracy that the RX series is famed for. TEST MENU TEST MENU & CONSOLIDATION ACCURATE RESULTS UNRIVALLED...
Open the catalog to page 4QUALITY CONTROL FLEXIBILITY & VERSATILITY COST SAVINGS Increased functionality Smart technology designed confidence in your results maximises testing capabilities to avoid additional costs Simple twice yearly preventative charts, calibration curves and QC can be generated via diffraction grating maintenance reduces the likelihood statistics for reliable results. ensuring a multitude of chemistries Users can view QC history. are possible on one system. Extensive test menu allows consolidation 7 different calibration options Continuous loading hatch allows of testing, and the ability to run...
Open the catalog to page 5SYSTEM OVERVIEW REAGENT CAROUSEL The RX modena reagent carousel has 100 cooled positions for 50x70ml & 50x20ml reagent bottles. An automatic barcode will identify the reagents added to the carousel which will be cooled between 8oC and 15oC to allow for a greater on-board stability. CUVETTES On-board the RX modena there are 153 semi-permanent cuvettes with a life span of 3-6 months. Cuvette check function ensures that only clean and viable reaction vessels are used. The user will be notified when cuvettes are required to be replaced. WASH STATION A 7 stage washing process includes acid,...
Open the catalog to page 7THE RX SERIES TEST MENU CLINICAL AUTOIMMUNE: Complement Component 3 Complement Component 4 CRP CRP Full Range (0.3-160mg/l) CRP High Sensitivity IgA IgE IgG IgM Rheumatoid Factor BASIC METABOLIC PROFILE: Calcium CO2 Total Chloride Creatinine Glucose Potassium Sodium Urea BONE PROFILE: Alkaline Phosphatase Calcium Phosphorus Total Protein CARDIAC: Cholesterol CK -MB CK-NAC CRP CRP Full Range (0.3 -160mg/l) CRP High Sensitivity Direct HDL Cholesterol Direct LDL Cholesterol Homocysteine Lipoprotein (a) sdLDL Triglycerides COMPREHENSIVE METABOLIC PROFILE: Albumin Alkaline Phosphatase ALT AST...
Open the catalog to page 8Albumin Alkaline Phosphatase ALT (GPT) Aldolase Ammonia Amylase AST (GOT) Bile Acids Bilirubin Calcium Chloride Cholesterol Cholinesterase (Butyryl) CK-NAC CO2 Total Copper Creatinine Canine CRP Fructosamine Gamma - GT GLDH Glucose Glycerol Iron (UIBC) Lactate Lactate Dehydrogenase LDL Lipase Magnesium NEFA (Non-Esterified Fatty Acids) Phosphorus (Inorganic) Potassium Ranbut (D-3-Hydroxybutyrate) Ransel (Glutathione Peroxidase) Ransod (Superoxide Dismutase) Sodium Total Protein Triglycerides Urea Uric Acid Urinary Protein Zinc THERAPEUTIC DRUGS: Phenobarbitol Valproic Acid DRUGS OF ABUSE:...
Open the catalog to page 9SOFTWARE The RX modena offers intuitive software through an interactive, Windows based touch screen display. This technology allows the user to easily navigate through the testing screens of the analyser, enabling easy access to information and control of operations from the main screen using informative tabs. Smart software automatically calculates remaining reagent volumes and the number of tests available, including their stability. The RX modena software is capable of connecting to LIMS (Laboratory Information Management System) via ASTM standard. CHEMISTRY PARAMETERS The operator can...
Open the catalog to page 10Maintenance on the RX modena is fast and effective. The run monitor displays full patient demographics. There are several simple steps to carry out daily, weekly and This screen indicates the number of tests and time left until monthly. Minimal daily maintenance is required. completion. The operator can add emergency STAT samples from this screen. QUALITY CONTROL The QC screen generates Levey-Jennings charts and The software displays the current valid calibration for each calibration curves, allowing for a visual performance assessment assay installed, the reagent blank absorbance (if...
Open the catalog to page 11Fully automated on-board haemolysis function for HbA1c testing Economic platform with water consumption of less than 20 litres per hour at peak usage Continuous loading hatch allows samples to be analysed quickly and 09 easily during each run Automatic wake up and sleep functionality including programmable daily maintenance 153 cuvettes on-board with cuvette check function Interactive touch-screen technology with Windows® based software
Open the catalog to page 12ORDERING & CUSTOMER SUPPORT In choosing to purchase the RX modena from Randox you are partnering with a company that has over 40 years’ experience in the IVD industry and clinical chemistry analyser placements in over 120 countries worldwide. Customers needs vary and Randox sales staff and distributor partners will work with your laboratory to create a bespoke package to suit your requirements. Randox Laboratories provide customers with an unrivalled technical support service. ORDERING INFORMATION RX modena analyser For more information contact your local representative, or email us at:...
Open the catalog to page 13SPECIFICATIONS PHYSICAL DIMENSIONS Height PERFORMANCE CHARACTERISTICS Throughput 1200 tests per hour including ISE 800 photometric tests per hour Analyser accreditation Analyser type Compact fully automated random access floor standing clinical analyser Assay types End point, 2 point end, rate, 2 point rate and ISE REAGENT & SAMPLE SYSTEM Reagent capacity 11 Reagent identification Reagent inventory Reagent pipette Removable tray with 100 cooled positions (50 positions for 70ml bottles and 50 positions for 20ml bottles) Automatic barcode reagent identification Calculation of remaining...
Open the catalog to page 14All Randox Laboratories catalogs and technical brochures
-
Acusera New Controls
8 Pages
-
Acusera 24.7
24 Pages
-
Acusera Third Party Controls
108 Pages
-
Acusera SMART Controls
12 Pages
-
Company Overview
40 Pages
-
LT735 Vivalytic Overview
32 Pages
-
Reagents Brochure
64 Pages
-
sdLDL-C
8 Pages
-
RX SERIES ANALYSER OVERVIEW
24 Pages
-
RX misano
20 Pages
-
RX Daytona Plus
20 Pages
-
Rx Imola
20 Pages
-
RX Monaco
20 Pages
-
2024 Product List
64 Pages
-
LT107 Evidence Investigator
32 Pages
-
VeraSTAT-V
16 Pages
-
LT033 RIQAS Explained
64 Pages
-
VERASTAT
16 Pages
-
Endocrine Array
4 Pages
-
Cerebral Arrays
4 Pages
-
Thyroid Arrays
4 Pages
-
Respiratory Multiplex Array
8 Pages
-
LT253 Molecular Diagnostics
20 Pages
-
LT367 FH Array Brochure
4 Pages
-
The role of EQA in QC
8 Pages
-
Basic QC Stastics
8 Pages
-
Commutability Guide
4 Pages
-
How to measure uncertainty
8 Pages
-
ISO 15189 Educational Guide
8 Pages
-
Troubleshooting QC Errors
8 Pages
-
Qnostics
52 Pages
-
Adiponectin LT519
28 Pages
-
Specific Proteins
40 Pages
-
Linearity sets
12 Pages
-
Antioxidants
16 Pages
-
Cardiology & Lipid Testing
28 Pages
-
Diabetes Portfolio
28 Pages
-
Total Bile Acids
4 Pages
-
VIVALYTIC
30 Pages
-
RANDOX DISCOVERY
36 Pages
-
HbA1c
2 Pages
-
Preparing QC
1 Pages
-
Point of Care Testing
12 Pages
-
LT394 Using QC Multirules
1 Pages
-
Guide to running QC
1 Pages
-
Tumour Marker Arrays
4 Pages
-
Which QC is the Right QC
8 Pages
-
How often is right for QC
6 Pages
-
Cardiac Risk Multiplex Array
4 Pages
-
LT241 Metabolic Array MAY15
8 Pages
-
KRAS / BRAF / PIK3CA Array*
4 Pages
-
Custom Arrays for Biochip
12 Pages
-
LT169 Cardiac Array
4 Pages
Archived catalogs
-
ACUSERA
108 Pages
-
Evidence Evolution
28 Pages
-
Evidence
16 Pages
-
Metabolic Syndrome Arrays
8 Pages
-
STI Multiplex Array
8 Pages
-
Molecular Testing
16 Pages
-
Evidence Investigator
20 Pages
-
Fertility Array
4 Pages
-
Rx Daytona
16 Pages
-
Evidence Investigator
16 Pages
-
Evidence
16 Pages