
Group: Randox

Catalog excerpts

RX MONACO A fully automated clinical chemistry analyser A PHOTOMETRIC THROUGHPUT OF 170 TESTS PER HOUR
Open the catalog to page 1
A CONVENIENT SOLUTION FOR LOW TO MID VOLUME CLINICAL CHEMISTRY TESTING
Open the catalog to page 2
SYSTEM OVERVIEW TEST MENU ORDERING INFORMATION RANDOX - A GLOBAL DIAGNOSTIC SOLUTIONS PROVIDER
Open the catalog to page 3
BENEFITS The RX monaco is a fully automated, discrete, random access clinical chemistry analyser capable of performing routine & specialised testing and emergency STAT sampling. At optimal configuration, the RX monaco performs 170 photometric tests per hour providing cost effective, high quality testing for small to medium sized laboratories. Customers can choose between a benchtop system or add a stand to suit their unique circumstances. The RX monaco combines robust hardware and intuitive software with the world leading RX series test menu for unrivalled performance. TEST MENU TEST MENU &...
Open the catalog to page 4
QUALITY CONTROL FLEXIBILITY & VERSATILITY COST SAVINGS Increased functionality Smart technology designed confidence in your results maximises testing capabilities to avoid additional costs Minimal maintenance required, charts, calibration curves and QC diffraction grating (340-800nm) giving just 2 preventative maintenance services statistics for reliable results. the RX monaco a wide range of testing per year means less down time Users can view QC history. capabilities ensuring a multitude Auto QC interval enables automatic Extensive test menu allows consolidation of testing, the ability to...
Open the catalog to page 5
SYSTEM OVERVIEW REAGENT & SAMPLE CAROUSEL A cooled carousel containing 66 user-definable positions are available for samples and 20ml and 70ml reagent bottles - dedicated reagents are available from Randox. Integrated barcode identification ensures smooth recognition of patient samples and reagents. The S/RPT pipette has liquid level detection and collision detection and is rinsed inside and out to prevent carryover. CUVETTES 120 semi-permanent reaction cuvettes lasting for 3-6 months. The reaction temperature is controlled by a water bath. WASH STATION A thorough 12 stage washing process...
Open the catalog to page 7
THE RX SERIES TEST MENU CLINICAL AUTOIMMUNE: Complement Component 3 Complement Component 4 CRP CRP Full Range (0.3-160mg/l) CRP High Sensitivity IgA IgE IgG IgM Rheumatoid Factor BASIC METABOLIC PROFILE: Calcium CO2 Total Chloride Creatinine Glucose Potassium Sodium Urea BONE PROFILE: Alkaline Phosphatase Calcium Phosphorus Total Protein CARDIAC: Cholesterol CK -MB CK-NAC CRP CRP Full Range (0.3 -160mg/l) CRP High Sensitivity Direct HDL Cholesterol Direct LDL Cholesterol Homocysteine Lipoprotein (a) sdLDL Triglycerides COMPREHENSIVE METABOLIC PROFILE: Albumin Alkaline Phosphatase ALT AST...
Open the catalog to page 8
Albumin Alkaline Phosphatase ALT (GPT) Aldolase Ammonia Amylase AST (GOT) Bile Acids Bilirubin Calcium Chloride Cholesterol Cholinesterase (Butyryl) CK-NAC CO2 Total Copper Creatinine Canine CRP Fructosamine Gamma - GT GLDH Glucose Glycerol Iron (UIBC) Lactate Lactate Dehydrogenase LDL Lipase Magnesium NEFA (Non-Esterified Fatty Acids) Phosphorus (Inorganic) Potassium Ranbut (D-3-Hydroxybutyrate) Ransel (Glutathione Peroxidase) Ransod (Superoxide Dismutase) Sodium Total Protein Triglycerides Urea Uric Acid Urinary Protein Zinc THERAPEUTIC DRUGS: Phenobarbitol Valproic Acid DRUGS OF ABUSE:...
Open the catalog to page 9
SOFTWARE The RX monaco is provided with familiar, Windows® based software and easily recognisable icons making it appealing and easy-to-use for all staff involved in its operation. Straightforward operation of the software results in minimal training requirements and enhanced productivity. The superior functionality of the quality control software generates Levey-Jennings charts and QC statistics for reliable patient results. LIMS (Laboratory Information Management System) connectivity is easily achievable via ASTM standard. Secure remote diagnostics is available to allow immediate support...
Open the catalog to page 10
The operator is instructed via easy to follow steps on how The run monitor displays full patient demographics. Users to carry out daily, weekly, monthly and periodic maintenance. can view the status of samples in real time including time left Daily maintenance takes only 5 minutes to do. The analyser has to completion. This screen also indicates number of tests a countdown timer to show when routine servicing is due. remaining before the run is due to finish. QUALITY CONTROL The QC screen generates Levey-Jennings charts for a visual The software displays the current valid calibration for...
Open the catalog to page 11
Maximum water consumption is only 5.5 litres per hour 12 wavelengths ranging from 340-800nm Barcode readers for both sample and reagent identification Easy to use Windows® based software Low sample dead volume of just 100μl
Open the catalog to page 12
ORDERING & CUSTOMER SUPPORT In choosing to purchase the RX monaco from Randox you are partnering with a company that has over 35 years’ experience in the IVD industry and clinical chemistry analyser placements in over 120 countries worldwide. Customers needs vary and Randox sales staff and distributor partners will work with your laboratory to create a bespoke package to suit your requirements. Randox Laboratories provide customers with an unrivalled technical support service. ORDERING INFORMATION RX monaco analyser (benchtop) RX monaco analyser with stand For more information contact your...
Open the catalog to page 13
SPECIFICATIONS PHYSICAL DIMENSIONS Height PERFORMANCE CHARACTERISTICS Throughput 170 tests per hour constant speed Analyser type Fully automated, discrete, random access bench-top clinical chemistry analyser Assay types End-point, rate, 2 point assays Daily maintenance – probe & mixer wash/water bath exchange/cuvette check REAGENT & SAMPLE SYSTEM 11 Reagent & Sample capacity Shared reagent & sample carousel with a total of 66 user defined positions (positions for reagents ≥ 3, positions for samples ≥ 9) Reagent cooling Reagent & sample Identification Internal barcode scanner Reagent...
Open the catalog to page 14
Water consumption Water requirements NCCLS type 1 or 2 purified water supply at 0.5 bar pressure 120 semi-permanant optical plastic cuvettes, 6mm optical path. Life span: 3-6 months OPTICAL SYSTEM Incubator temperature Light source Long life quartz halogen lamp (water cooled) Detection principal Detector method Direct absorbance in cuvette (monochromatic or bi-chromatic) Wavelength accuracy Absorbance range CALIBRATION & QC Calibration principal 1 point, 2 point, multi-point, non-linearity method Quality control OPERATING SYSTEM External output POWER REQUIREMENTS Power supply Power output
Open the catalog to page 15All Randox Laboratories catalogs and technical brochures
-
LT735 Vivalytic Overview
32 Pages
-
Acusera New Controls
8 Pages
-
Acusera 24.7
24 Pages
-
Acusera Third Party Controls
108 Pages
-
Acusera SMART Controls
12 Pages
-
Company Overview
40 Pages
-
Reagents Brochure
64 Pages
-
sdLDL-C
8 Pages
-
RX SERIES ANALYSER OVERVIEW
24 Pages
-
RX modena
20 Pages
-
RX misano
20 Pages
-
RX Daytona Plus
20 Pages
-
Rx Imola
20 Pages
-
2024 Product List
64 Pages
-
LT107 Evidence Investigator
32 Pages
-
VeraSTAT-V
16 Pages
-
LT033 RIQAS Explained
64 Pages
-
VERASTAT
16 Pages
-
Endocrine Array
4 Pages
-
Cerebral Arrays
4 Pages
-
Thyroid Arrays
4 Pages
-
Respiratory Multiplex Array
8 Pages
-
LT253 Molecular Diagnostics
20 Pages
-
LT367 FH Array Brochure
4 Pages
-
The role of EQA in QC
8 Pages
-
Basic QC Stastics
8 Pages
-
Commutability Guide
4 Pages
-
How to measure uncertainty
8 Pages
-
ISO 15189 Educational Guide
8 Pages
-
Troubleshooting QC Errors
8 Pages
-
Qnostics
52 Pages
-
Adiponectin LT519
28 Pages
-
Specific Proteins
40 Pages
-
Linearity sets
12 Pages
-
Antioxidants
16 Pages
-
Cardiology & Lipid Testing
28 Pages
-
Diabetes Portfolio
28 Pages
-
Total Bile Acids
4 Pages
-
VIVALYTIC
30 Pages
-
RANDOX DISCOVERY
36 Pages
-
HbA1c
2 Pages
-
Preparing QC
1 Pages
-
Point of Care Testing
12 Pages
-
LT394 Using QC Multirules
1 Pages
-
Guide to running QC
1 Pages
-
Tumour Marker Arrays
4 Pages
-
Which QC is the Right QC
8 Pages
-
How often is right for QC
6 Pages
-
Cardiac Risk Multiplex Array
4 Pages
-
LT241 Metabolic Array MAY15
8 Pages
-
KRAS / BRAF / PIK3CA Array*
4 Pages
-
Custom Arrays for Biochip
12 Pages
-
LT169 Cardiac Array
4 Pages
Archived catalogs
-
ACUSERA
108 Pages
-
Evidence Evolution
28 Pages
-
Evidence
16 Pages
-
Metabolic Syndrome Arrays
8 Pages
-
STI Multiplex Array
8 Pages
-
Molecular Testing
16 Pages
-
Evidence Investigator
20 Pages
-
Fertility Array
4 Pages
-
Rx Daytona
16 Pages
-
Evidence Investigator
16 Pages
-
Evidence
16 Pages