
Group: Randox

Catalog excerpts

VIVALYTIC THE ALL IN ONE MOLECULAR SOLUTION
Open the catalog to page 1
MAKING A POINT TO CARE
Open the catalog to page 2
CONTENTS Vivalytic & Cartridges Vivalytic Vivalytic Cartridges Vivalytic Workflow Vivalytic Test Menu Respiratory Infections Testing Genitourinary Infections Testing Hospital Acquired Infections Testing Vivalytic Specification Specifications Vivasuite Vivalytic Ordering Information Ordering Information
Open the catalog to page 3
Vivalytic & Cartridges
Open the catalog to page 5
Vivalytic & Cartridges Vivalytic Molecular Diagnostics at the Point of Care Vivalytic brings innovation to the Molecular Diagnostic testing market. It is the result of a successful collaboration between German technology expert, Bosch Healthcare Solutions and Randox Laboratories, a global IVD company and one of Bosch’s first bio-content partners. Bosch Healthcare Solutions has developed the Vivalytic system, which includes the test cartridge and analyser. Randox as the first partner on the Vivalytic platform, supplies Bosch with biological components needed inside the test cartridges to...
Open the catalog to page 6
Vivalytic & Cartridges Vivalytic Cartridges Vivalytic cartridges are compact, technologically advanced Molecular Diagnostic tests utilising micro-fluidics to enable simple and accurate diagnostic testing. Vivalytic cartridges are powered by a variety of technologies, dependent upon the test application. Hi-Plex and Low-Plex tests can be analysed on the Vivalytic system. Hi-Plex tests utilise Randox patented Biochip Array Technology, enabling endpoint qualitative PCR and providing multiple test results from each sample. Low-Plex tests are based on a variety of detection methods including...
Open the catalog to page 8
Vivalytic & Cartridges Hi-Plex Vivalytic Cartridges Powered by Randox Biochip Technology Randox patented Biochip Technology allows simultaneous detection of multiple targets from a single patient sample. The biochip detection system is based on a chemiluminescent signal, this is the emission of light, without heat, as a result of a chemical reaction. Each biochip is prefabricated with spatially discrete testing regions (DTR’s). Each DTR represents an individual test. Each DTR can be occupied with oligonucleotides specific to a pathogen or target of interest. The Hi-Plex capabilities of...
Open the catalog to page 9
Vivalytic & Cartridges Vivalytic Workflow 4 Easy Steps for Optimised Workflow Intuitive engineering of Vivalytic ensures the analyser is user friendly. The process of patient sample to result comprises a very simple 4 step workflow. To begin the test, the user scans or enters sample information. The cartridge code is then scanned into the embedded Vivalytic software. The user then adds sample into the dedicated cartridge slot, closes the lid and inserts the cartridge into the Vivalytic. The touchscreen display will countdown the time remaining to test completion. Results will be displayed...
Open the catalog to page 10
Vivalytic Test Menu
Open the catalog to page 13
Vivalytic Test Menu Respiratory Viral Respiratory Tract Infections (VRI) *In Development The Viral Respiratory Tract Infections (VRI) test cartridge detects 10 viral respiratory infections including SARS-CoV-2 in 2 hours 30 minutes. The panel provides a comprehensive respiratory screen detecting co-infections, enabling informed treatment decisions to be made. Sample Type: Nasopharyngeal or Oropharyngeal Swab Sample Volume: 300 μL Detection Method: Randox Biochip Technology (end-point PCR) Time to Result: 2 hours 30 minutes VIRUSES SARS-CoV-2 Adenovirus A/B/C/D/E Sarbecovirus (SARS, SARS...
Open the catalog to page 14
Vivalytic Test Menu SARS-CoV-2 Dual Target SARS-CoV-2 dual target real time PCR cartridge provides clear and concise results in a timely manner, direct at the point of care. This enables individuals to take the recommended safety precautions without delay. The SARS-CoV-2 dual target rapid test allows for detection of both the E-gene and N-gene sequence. Sample Type: Nasopharyngeal or Oropharyngeal Swab Sample Volume: 300 μL Detection Method: Real-Time PCR Time to Result: 49 minutes VIRUS SARS-CoV-2 (E gene and N gene sequence) SARS-CoV-2 Dual Target, Flu A/B, and RSV Patients infected with...
Open the catalog to page 15
Vivalytic Test Menu Chronic Lung Disease (CLD) *Planned Panel The Chronic Lung Disease (CLD) cartridge is a world leading multiplex test, detecting 131 species associated with long term lung disease e.g. Cystic Fibrosis and Chronic Obstructive Pulmonary Disease (COPD). The 131 species are simultaneously detected across this 31-plex array and includes bacterial, viral, fungal targets and an antibiotic resistance marker from a single sputum sample. Furthermore, the MecA antibiotic resistance marker is included to assist antibiotic stewardship. VIRUSES Adenovirus Respiratory syncytial virus A...
Open the catalog to page 16
Vivalytic Test Menu Hospital Acquired Infections MRSA/SA MRSA/SA is a qualitative test detecting and differentiating between methicillin-resistant Staphylococcus aureus (MRSA), methicillin-sensitive Staphylococcus aureus (MSSA) and methicillin-resistant coagulasenegative Staphylococci (MRCoNS). By using one single cartridge, the Vivalytic MRSA/SA test aids in the diagnosis of MRSA infection in a speedy manner so that appropriate antibiotic treatment can be applied, and complications prevented. Sample Type: Swab Sample Volume: 600 μL Detection Method: Real-Time PCR Time to Result: 53 minutes...
Open the catalog to page 17
Vivalytic Test Menu Mycoplasma genitalium, Mycoplasma hominis & Ureaplasma parvum/urealyticum Aiding in the diagnosis and containment of sexually transmitted infections (STIs) of symptomatic and asymptomatic individuals, the MG, MH, UP/UU test guides appropriate treatment decisions at the earliest opportunity for improved patient management, prevention of transmission and supporting emerging macrolide resistance. MG, MH, UP/UU belong to the group of human pathogenic bacterial species associated with STIs even though particularly Ureaplasma ssp. are primarily considered as commensal...
Open the catalog to page 18
Vivalytic Test Menu
Open the catalog to page 19
VIVALYTIC FASCINATES WITH A MARKEDLY MINIMALIST DESIGN WHOSE STRENGTH LIES IN ITS HIGH USERFRIENDLINESS AND FUNCTIONALITY
Open the catalog to page 20
Vivalytic Specifications
Open the catalog to page 23
Vivalytic Specifications Vivalytic Specifications TECHNICAL DATA Display 7 inch 16:10, 1024 x 600 pixel touchscreen Operating Air Pressure Range 850-1,100 hPa, corresponds to pressure range 0-1, 400m above sea level Operating Temperature Storage Temperature Data Transfer Ethernet 10/100, MB, WLAN 2.4 GHz, (802.11b/g/n); internal: Bluetooth v4.1, 2.4 GHz (low energy), USB 2.0 Electromagnetic Compatibility Length 400 mm, Width 204 mm, Height 388 mm Storage Humidity Operating Humidity Electrical Data Instrumental Safety IEC/EN 61010-1, IEC/EN 61010-2-010 IEC/EN 61010-2-101, Regulation 2017/746...
Open the catalog to page 24All Randox Laboratories catalogs and technical brochures
-
LT735 Vivalytic Overview
32 Pages
-
Acusera New Controls
8 Pages
-
Acusera 24.7
24 Pages
-
Acusera Third Party Controls
108 Pages
-
Acusera SMART Controls
12 Pages
-
Company Overview
40 Pages
-
Reagents Brochure
64 Pages
-
sdLDL-C
8 Pages
-
RX SERIES ANALYSER OVERVIEW
24 Pages
-
RX modena
20 Pages
-
RX misano
20 Pages
-
RX Daytona Plus
20 Pages
-
Rx Imola
20 Pages
-
RX Monaco
20 Pages
-
2024 Product List
64 Pages
-
LT107 Evidence Investigator
32 Pages
-
VeraSTAT-V
16 Pages
-
LT033 RIQAS Explained
64 Pages
-
VERASTAT
16 Pages
-
Endocrine Array
4 Pages
-
Cerebral Arrays
4 Pages
-
Thyroid Arrays
4 Pages
-
Respiratory Multiplex Array
8 Pages
-
LT253 Molecular Diagnostics
20 Pages
-
LT367 FH Array Brochure
4 Pages
-
The role of EQA in QC
8 Pages
-
Basic QC Stastics
8 Pages
-
Commutability Guide
4 Pages
-
How to measure uncertainty
8 Pages
-
ISO 15189 Educational Guide
8 Pages
-
Troubleshooting QC Errors
8 Pages
-
Qnostics
52 Pages
-
Adiponectin LT519
28 Pages
-
Specific Proteins
40 Pages
-
Linearity sets
12 Pages
-
Antioxidants
16 Pages
-
Cardiology & Lipid Testing
28 Pages
-
Diabetes Portfolio
28 Pages
-
Total Bile Acids
4 Pages
-
RANDOX DISCOVERY
36 Pages
-
HbA1c
2 Pages
-
Preparing QC
1 Pages
-
Point of Care Testing
12 Pages
-
LT394 Using QC Multirules
1 Pages
-
Guide to running QC
1 Pages
-
Tumour Marker Arrays
4 Pages
-
Which QC is the Right QC
8 Pages
-
How often is right for QC
6 Pages
-
Cardiac Risk Multiplex Array
4 Pages
-
LT241 Metabolic Array MAY15
8 Pages
-
KRAS / BRAF / PIK3CA Array*
4 Pages
-
Custom Arrays for Biochip
12 Pages
-
LT169 Cardiac Array
4 Pages
Archived catalogs
-
ACUSERA
108 Pages
-
Evidence Evolution
28 Pages
-
Evidence
16 Pages
-
Metabolic Syndrome Arrays
8 Pages
-
STI Multiplex Array
8 Pages
-
Molecular Testing
16 Pages
-
Evidence Investigator
20 Pages
-
Fertility Array
4 Pages
-
Rx Daytona
16 Pages
-
Evidence Investigator
16 Pages
-
Evidence
16 Pages