RAYPA Leading Lab Technologies Food analysis FIBRE EXTRACTION SYSTEM F-6P RELIABLE, VERSATILE AND ECONOMIC FIBRE EXTRACTION SYSTEM FOR EFFICIENT CRUDE AND DETERGENT FIBRE ANALYSES

Open the catalog to page 1
FIBRE EXTRACTOR - F-6P SERIES - 2

Fibre extraction system Our fibre extraction system is specially optimized for the determination of Crude, Acid and Neutral fibre together with other fractions such as cellulose, hemicellulose and lignin according to the universally known Weende and Van Soest methods. Its flexibility to analyze a wide range of samples with subsequent or individual extraction, including boiling and filtration steps, makes our hot fibre extractor suitable for multiple settings and applications. F-6P is designed to guarantee accurate and precise results in compliance with the international standardized methods...

Open the catalog to page 2
FIBRE EXTRACTOR - F-6P SERIES - 3

FEATURES HIGHLY EFFICIENT Simultaneous single or sequential hot extraction of 6 six samples under identical conditions including boiling and filtration. TEMPERATURE CONTROL Control of heat generation by a manual regulator. Guarantees rapid temperature rise until reagent boiling and temperature maintenance at lower levels as required. EXEMPT FROM SAMPLE LOSS Specialized heat resistant Pyrex® crucibles with filters are used for the extraction and filtration of components, preventing any sample loss as the crucibles can be used as sample vessels during extraction, weighing, drying and...

Open the catalog to page 3
FIBRE EXTRACTOR - F-6P SERIES - 4

Fibre extraction system GENERAL OVERVIEW OF VAN SOEST METHOD FOR FIBRE COMPONENTS ISOLATION SAMPLE Cell soluble components Neutral Detergent Fibre (NDF) Acid Detergent Solution (ADS) Acid Detergent Fibre (ADF) Neutral Detergent Solution (NDS) Acid Detergent Solution (ADS) Acid Detergent Lignin (ADL) GENERAL OVERVIEW OF WEENDE METHOD FOR CRUDE FIBRE DETERMINATION SAMPLE PREPARATION CRUDE FIBRE Traditional crude fibre extraction, also known as the Weende method, is commonly used to estimate the quality of foods of plant origin on the premise that it constitutes their least digestible...

Open the catalog to page 4
FIBRE EXTRACTOR - F-6P SERIES - 5

MAIN FEATURES OF OUR SOLUTION FOR FIBRE EXTRACTIONS INTEGRATED AIR PUMP TO BREAK COMPACT CLUMPS (POSITIVE PRESSURE) DURABLE EXTERNAL FRAME • AISI-304 stainless steel • Epoxy coating • Easy to clean • Corrosion resistant ADJUSTABLE TEMPERATURE REGULATION PRESSURE CONNECTION TO F-6P TO BREAK COMPACT CLUMPS (POSITIVE PRESSURE) WATER REFRIGERATION CIRCUIT 6 SIMULTANEOUS EXTRACTION PLACES DURABLE EXTERNAL FRAME • AISI-304 stainless steel • Epoxy coating • Easy to clean • Corrosion resistant 6 SIMULTANEOUS EXTRACTION PLACES INDIVIDUAL 3 POSITION VALVES • Drain • Closed • Pressure support HEATING...

Open the catalog to page 5
FIBRE EXTRACTOR - F-6P SERIES - 6

2. Sample mixing with solvent at boiling temperature and 2. Sample mixing with solvent at room temperature. refrigeration circuit turned on. 3. Vacuum-assisted filtration with the integrated peristaltic 3. Vacuum-assisted filtration with the integrated peristaltic pump, solvent can be recovered. pump, solvent can be recovered. During filtration, it may be necessary to break compact clumps During filtration, it may be necessary to break compact clumps using the integrated air pump. using F-6P's air pump connection. 6 FIBRE EXTRACTION SYSTEM - F-6P

Open the catalog to page 6
FIBRE EXTRACTOR - F-6P SERIES - 7

RECOMMENDED APPLICATIONS • Determination of crude fibre content according to Weende. • Determination of Acid Detergent Fibre (ADF) and Neutral Detergent Fibre (NDF) according to Van Soest. • Determination of Acid Detergent Lignin (ADL). TECHNICAL DESCRIPTION • Simultaneous single or sequential hot or cold extraction of 6 six samples under identical conditions including boiling, rinsing and filtration. • Integrated system without sample transfer or sample loss, samples can be dried or weighed on every stage via heat resistant crucibles. • Heating by a quartz heater controlled by a manual...

Open the catalog to page 7
FIBRE EXTRACTOR - F-6P SERIES - 8

Fibre extraction system TECHNICAL SUMMARY OF F-6 P Extractor general classification Extraction places Standards compliance General info Determination of Crude fibre content according to Weende Determination of Acid Detergent Fibre (ADF) and Neutral Detergent Fibre (NDF) according to Van Soest Determination of Acid Detergent Lignin (ADL) Recommended applications Crucibles Crucibles gaskets Materials Boiling vessels Tubing External housing Pyrex® glass Viton® Borosilicate 3.3 Silicone and Viton® AISI-304 stainless steel painted with epoxy resin Quarts he ater Air pump (positive pressure to...

Open the catalog to page 8
FIBRE EXTRACTOR - F-6P SERIES - 9

6 GLASS CRUCIBLES OF P2 POROSITY V 1 TONG FOR AN INDIVIDUAL MANIPULATION OF CRUCIBLES V 1 TONG FOR A SIMULTANEOUS MANIPULATION OF 6 CRUCIBLES V SEVERAL CONNECTION HOSES V SEVERAL CONNECTION HOSES CLAMPS V Material Pyrex® glass COLD FAT EXTRACTION SYSTEM Number of sample positions 6 Compatible crucibles dimensions 0 x H mm 34 x 60 FIBRE EXTRACTION SYSTEM - F-6P 9

Open the catalog to page 9
FIBRE EXTRACTOR - F-6P SERIES - 10

THECHNICAL DATA Dimensions and performance Reference International standardized methods F-6P F-6P hot fibre extractors are fabricated guaranteeing compliance with a variety of international standards such as AOAC, AACC and ISO. Frequence Hz Sample capacity Batch units FOOD AND FEED INDUSTRY Main fields of application Glass crucible dimensions Ø x H mm *Also available with a voltage of 115 V. Regulations Our F-6P fibre extraction system is designed to comply with the strictest international directives and standards, including the following: • EN-61010-1 Safety requirements for electrical...

Open the catalog to page 10

All Raypa catalogs and technical brochures