1. Catalogs
  2. RAYPA
  3. STANDARD MEDIA PREPARATORS - AE-MP SERIES

STANDARD MEDIA PREPARATORS - AE-MP SERIES

STANDARD MEDIA PREPARATORS - AE-MP SERIES
1 / 39 PagesView full catalog

STANDARD MEDIA PREPARATORS - AE-MP SERIES

Product catalog summary
General Specifications
The AE-MP Series media preparators are designed to enhance efficiency in microbiology and biotechnology labs by automating culture media preparation. They feature a powerful heating system and rapid cooling to produce large volumes of sterile culture media efficiently.
Integrated Processes
The AE-MP Series combines five key processes: preparation with automated mixing and rapid heating, precise sterilization, fast cooling, adjustable dispensing, and automatic cleaning to prevent contamination.
Advantages Over Traditional Methods
Compared to traditional autoclaves, the AE-MP Series offers faster heating and cooling, automated processes, and improved safety features.
Construction and Quality
Built with high-quality materials, the sterilization chamber and components ensure durability and optimal performance.
Controller and Monitoring
Features include adjustable parameters, cycle safeguards, and data management with automatic USB backup and SWMP software.
Productivity Strategies
Special versions for high-density media, integrated chillers, and self-cleaning functions enhance productivity.
Installation and Maintenance
Comprehensive support is provided for installation and maintenance, with options for preventive and standard maintenance contracts.
Technical Data
Detailed specifications ensure compliance and reliability, with safety features and certifications included.
Efficiency and Time Savings
The fast cooling system reduces cooling time by up to 90%, and enhanced heating capacity models speed up the heating phase, optimizing workflow and ensuring traceability.
Accurate Sterilization
Flexible temperature probes allow precise control of sterilization processes, ensuring reproducibility and minimizing contamination risks.
Safety Features
Includes burn protection, automatic door locking, insulated covers, and alarm systems to reduce human error.
Model Variations
Available in six models, from benchtop to floor-standing, with capacities from 8 to 90 liters, using high-quality stainless steel for durability.
Dispensing Options
Managed through a peristaltic pump with adjustable speeds, designed for accuracy and flexibility.
Automatic Cleaning
High-temperature steam cleaning reduces contamination risk and eliminates manual cleaning needs.
Specifications and Procedures
Emphasizes using supplied bottles for steam collection and details purging functions to prevent medium solidification.
Water Quality
Requires decalcified, contaminant-free water for cooling and purified water for steam generation.
Steam Generation
Uses Incoloy®825 elements for corrosion resistance, with F0 value-managed sterilization for precise control.
F0, D-value, and Z-value
These parameters optimize sterilization processes, ensuring high-quality culture media.
Advantages of F0 Programs
Preserve culture medium quality, reduce energy consumption, and ensure uniform lethality.
Key Features
  • Handles lower minimum volumes, beneficial for small batches.
  • Ensures traceability and process control with flexible probes and F0 cycle regulation.
  • Offers pressure control for sterilization efficacy.
  • Equipped with EMC-FILTER and UPS systems for power fluctuation protection.
  • Fast cooling system reduces phase duration by up to 90%.
Operational Procedures
  • Includes pressure and temperature control for effective sterilization.
  • Cycle safeguards ensure proper operation and prevent errors.
Applications
Suitable for microbiology applications, especially with thermolabile substances.
Specifications
Features include open door sensors, pneumatic door locking, and integrated sterilization process evaluation.
Calibration and Updates
Sensors can be calibrated via a microprocessor screen, with USB support for updates.
Data Management
Options include thermal printers and SWMP software for detailed data logging.
Productivity Strategies
Includes special versions for increased heating capacity and high-density media.
Accessories
Available accessories improve efficiency and ease of use.
Customer Support
Offers comprehensive support services, including training and maintenance contracts.
Technical Specifications
Models vary in capacity and cycle duration, complying with EU regulations.
Certifications
Complies with international standards and EU directives.
Cycle Time and Electrical Connection
Details cycle times and electrical configurations for different models.
Technical Drawings
Provide dimensions and connection details for each model.
See more

Catalog excerpts

STANDARD MEDIA PREPARATORS - AE-MP SERIES-1

The equipment shown is representative; its design may be subject to change as part of manufacturing improvements or adjustments. Standard media preparators AE-MP Series Technical information

 Open the catalog to page 1
STANDARD MEDIA PREPARATORS - AE-MP SERIES-2

AE-MP SERIES - TECHNICAL DATA SHEET

 Open the catalog to page 2
STANDARD MEDIA PREPARATORS - AE-MP SERIES-3

Standard media preparators General specifications Our standard media preparators from the AE-MP Series have been created to streamline the operational workflow of culture media preparation in microbiology and biotechnology laboratories. They streamline the entire process, reducing total time and workload, while efficiently producing large volumes of sterile culture media. This is achieved through a powerful heating system and a fast cooling system that is activated at the end of the sterilization process. These media preparators are used in a wide variety of applications such as the preparation...

 Open the catalog to page 3
STANDARD MEDIA PREPARATORS - AE-MP SERIES-4

Automation of culture media preparation The AE-MP Series media preparators are engineered to transform the culture The following table presents a detailed comparison between culture media media preparation process by consolidating multiple stages into a single preparation using the conventional autoclave method and our AE-MP Series device. This integration brings substantial advantages over traditional autoclave media preparators, illustrating the distinct advantages provided by our methods, including reduced preparation time, enhanced reproducibility, and minimized contamination risk, among...

 Open the catalog to page 4
STANDARD MEDIA PREPARATORS - AE-MP SERIES-5

Benefits of AE-MP Series media preparators Efficiency and time savings Professional reproducibility reduction in the duration of the cooling phase. To further speed up the process, processing the entire preparation under the same conditions, much greater we offer models with enhanced heating capacity that significantly reduce the accuracy and reproducibility is achieved than with the traditional autoclave duration of the heating phase. Moreover, the integration and automation of The fast cooling system is key in our media preparators, offering up to 90% multiple functions within the same equipment...

 Open the catalog to page 5
STANDARD MEDIA PREPARATORS - AE-MP SERIES-6

References maximum capacity for preparing culture media L Inner vessel dimensions 0 x H mm 210 x 236 330 x 236 330 x 461 330 x 696 420 x 594 AE-MP SERIES - TECHNICAL DATA SHEET 6

 Open the catalog to page 6
STANDARD MEDIA PREPARATORS - AE-MP SERIES-7

Understanding the operation of our media preparators Phases of a sterilization cycle T/P In this initial step, the powerful electric heating elements mounted inside COOLING TIME the sterilization chamber heat up rapidly, transferring energy to water to produce saturated steam and heat the inner vessel. B. Sterilization phase When the programmed sterilization temperature is reached, it is precisely maintained for the stipulated time. This step is controlled by a PT-100 temperature probe located inside the inner vessel in direct contact with the preparation. C. Cooling phase After finishing the...

 Open the catalog to page 7
STANDARD MEDIA PREPARATORS - AE-MP SERIES-8

Preparation Culture media preparation is a fundamental process in microbiology, tissue Speed control by an independent controller culture and biotechnology laboratories. Our standard media preparators are The AE-MP Series allows precise control of stirring speed via an independent designed to facilitate and optimize this process, combining advanced technology potentiometer located on the control panel, with speeds adjustable up to 200rpm. with ease of use. These devices not only ensure a homogeneous preparation, This feature enables tailoring of the mixing process to the specific requirements...

 Open the catalog to page 8
STANDARD MEDIA PREPARATORS - AE-MP SERIES-9

Accuracy and flexibility in managing the culture media dispensing phase are critical for safe processes and maximizing productivity. At RAYPA, we understand that each laboratory has unique needs and, therefore, we offer different options for managing the dispensing phase, designed to meet different requirements and production needs: Accessory recommended for automating and accelerating the dispensing phase in repetitive operations involving medium to large volumes. It is the ideal solution for dispensing culture media at high speed when using medium and large media preparators. Overview of dispensing...

 Open the catalog to page 9
STANDARD MEDIA PREPARATORS - AE-MP SERIES-10

It is the ideal complement for microbiology laboratories that use media preparators and need to perform accurate and safe dispensing in Petri dishes. This system stands out for its ability to execute multiple processes automatically and for its safety measures: the dispensing area is protected by a safety cover and an UV-C lamp that ensures the sterility of the filling area. There are four models available with capacities ranging from 101 to 241 Petri dishes and dispensing volumes ranging from 1mL to 1000mL. © Compatible with Petri dish data printing systems, such as LINX 89XX Series printers....

 Open the catalog to page 10
STANDARD MEDIA PREPARATORS - AE-MP SERIES-11

Automatic cleaning of the dispensing lines One of the most significant challenges when using any media preparator beginning the sterilization phase is always activated automatically. Therefore, the is dealing with microbial contamination issues and the manual cleaning metal nozzle must be placed inside the bottle provided with the media preparator requirements associated with its use after each rotation. Fortunately for our to avoid possible burns and to collect the condensed steam that is expelled customers, our media preparators feature an exclusive design that greatly during this procedure....

 Open the catalog to page 11
STANDARD MEDIA PREPARATORS - AE-MP SERIES-12

Steps to follow to enable the self-cleaning and disinfection function of the dispensing lines before the sterilization phase 1. Set the dosing selector to "CLOSED" mode. 2. Check that the dispensing line is not pinched by 3. Place the metal nozzle of the dispensing line the peristaltic pump or the external dosing station. inside the bottle supplied with the media preparator. Steps to follow for emptying the dispensing lines during the dispensing phase 2. Check that the dispensing line 3. Place the metal nozzle of the 4. Select the purge option with "CLOSED" mode. dispensing line inside of the...

 Open the catalog to page 12
STANDARD MEDIA PREPARATORS - AE-MP SERIES-13

Our standard media preparators have been specifically designed for the preparation of large quantities of culture media. All models are equipped with a powerful magnetic stirrer -adjustable from 50rpm to 200rpm-, a flexible probe, a fast cooling system via a water coil, and scalable dispensing with multiple usage options. Additionally, all units can be customized with accessories according to the specific requirements of the client, including a wide range of dispensing systems. RAYPA exclusively uses high-quality and easily replaceable components at all stages of the design and construction of...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.