Main Features
The AVS-N Series vertical benchtop autoclaves are designed for sterilizing general labware and metal utensils. They are compact, economical, and durable, requiring minimal resources such as water and power. These autoclaves are easy to install and maintain, needing only a power source and no dedicated plumbing.
Safety Features
The autoclaves include safety mechanisms like an overpressure safety valve, thermally insulated lid, overtemperature safety thermostat, open lid detection system, and a pneumatic system that locks the door under pressure.
Intended Use
These autoclaves are suitable for sterilizing laboratory waste bags, plastics, glassware, liquids, and metal utensils.
Advantages
The sterilization chamber and door are made of high-quality stainless steel (AISI-316L), resistant to corrosion. The equipment complies with EU standards and features a PID microprocessor with multiple programs, a PT-100 Class A temperature probe, and optional software for data management.
Working Principle
The autoclaves operate by heating water to produce steam, maintaining sterilization temperature, and cooling naturally or manually. The process is controlled by a temperature probe, with options for flexible probe control in liquid sterilization.
Control Panels
The AES-8 model features a digital microprocessor with a compact screen and multiple push-buttons. The AES-12 model offers a larger screen, more program options, and language support.
Recommended Settings and Users
These autoclaves are ideal for small laboratories and clinics seeking an economical and reliable solution. They feature adjustable sterilization parameters and are easy to use with intuitive controls.
Accessories
Available accessories include stainless steel wire baskets, a transport trolley, cable glands for external probes, a flexible core temperature probe, and printers for data logging.
Conclusion
The AVS-N Series autoclaves are perfect for entry-level users in small facilities, offering a compact, versatile, and safe solution for various sterilization needs.
Technical Summary of AVS-N Series Autoclaves
Available Models: AES-8 and AES-12
General Classification: Recommended for small facilities and general laboratories, these benchtop autoclaves are top-loading with a round chamber profile.
Recommended Type of Load: Suitable for culture media, liquids, laboratory waste bags, porous solids, wrapped loads, and glassware.
Sterilization Technology Features: Utilizes heating elements for steam generation and gravity displacement for purging. Data transfer is facilitated via RS-232, with options for integrated or external printers.
Sterilization Chamber and Door Specifications: The AES-8 model has an 8L chamber, while the AES-12 has a 15L chamber. Both models use AISI-304 for external material and AISI-18/10 or AISI-316L for the chamber. The heating elements are made of Incoloy® 825, and the gasket is silicone rubber. The sterilization temperature ranges from 100°C to 134°C, with maximum pressures of 1.5 Barg and 2.1 Barg, respectively. Doors open vertically with automatic locking under pressure.
User Interface and Microprocessor: Features a digital LCD display with varying sizes. The AES-8 has 1 program, while the AES-12 offers 10 programs. Both models have automatic microprocessor control and adjustable cycle parameters.
Other Specifications: Includes a water sterilization chamber, flexible core temperature probe, height-adjustable feet, and pressure gauge. Electric customization is available.
Safety Features: Equipped with a safety valve, thermostat, pneumatic door blocking system, open door sensor (AES-12 only), thermally insulated door, and various alarms.
Regulations: Complies with international standards such as EN-61010-1, EN-61010-2-040, EN-61326, AD 2000 Merkblatt, 2014/35/UE, 2014/30/UE, and 2014/68/UE.
General Features: The AES-8 and AES-12 models offer adjustable sterilization temperatures and times, with fully automatic control systems. They feature gravity displacement air purge systems and are constructed with AISI-304 stainless steel.
Specifications: The AES-8 has a total chamber volume of 8L, while the AES-12 has 15L. Both models have specific dimensions, net weights, power requirements, and standard voltages.
Additional Information: More details and installation guides are available at www.raypa.com.
See more

Catalog excerpts

VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-1

Vertical benchtop autoclaves without drying AVS-N Series CLASSIC LINE Technical information

 Open the catalog to page 1
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-2

+ STERILIZATION OF LABORATORY WASTE BAGS, PLASTICS, GLASSWARE, LIQUIDS AND METAL UTENSILS The AVS-N Series vertical benchtop autoclaves with top-loading access cover the fundamental needs for general labware and metal utensils sterilization in many facilities with the aim of streamlining the sterilization workflow. A compact footprint together with the optimization of resources such as water, power and operating time results in an affordable and efficient solution to manage laboratory workload in small facilities. A COMPACT FOOTPRINT THAT FITS ANYWHERE AVS-N Series autoclaves with chamber sizes...

 Open the catalog to page 2
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-3

Sterilization chamber and door made of high quality stainless steel grade AISI-316L extremely resistant to corrosion*. Temperature control by a PT-100 Class A temperature probe located within the sterilization chamber. Equipment built following all applicable European Union quality, regulatory and safety standards. Faster cooling phase in solids sterilization cycles through a steam release manual valve at the end of the sterilization. Heating by powerful electric elements made of Incoloy® 825 assembled inside the sterilization chamber and shielded by a protective grid. Adjustable temperature...

 Open the catalog to page 3
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-4

WORKING PRINCIPLE AVS-N Series autoclaves provide a simple and straightforward solution for the multiple sterilization needs of general laboratories including biological waste, contaminated media, small metal utensils, glassware and other laboratory items. The load has to be placed into the pressure vessel basket and, after manually filling the tank with purified water, the equipment starts to heat up and purge until the set combination of sterilization time and sterilization temperature is reached. HEATING PHASE STERILIZATION PHASE COOLING PHASE • In this initial step, the powerful heating elements...

 Open the catalog to page 4
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-5

DIGITAL MICROPROCESSOR AND COMPACT SCREEN • The screen shows current chamber temperature, sterilization parameters and error messages. MULTIPLE PUSH-BUTTONS AND PILOT LIGHTS FOR YOUR • To assist you while programming a sterilization cycle, the control panel has 2 pilot lights and 5 intuitive push-buttons. • At the end of the sterilization cycle an acoustic alarm sounds. 4 MODES TO REGULATE THE STERILIZATION CYCLE • Indefinitely at a set temperature after an initial delay. • During a finite period of time at a set temperature. • During a finite period of time at a set temperature after an initial...

 Open the catalog to page 5
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-6

AES-8 THE PERFECT AUTOCLAVE FOR ENTRY LEVEL USERS OF SMALL FACILITIES LOOKING FOR AN ECONOMIC, RELIABLE AND EASY TO USE BENCHTOP AUTOCLAVE WITH A SMALL FOOTPRINT. • Suitable to sterilize glassware, plastics, laboratory waste bags, small metal utensils and small volumes of liquids and culture media. • Entry level users of small facilities such as small laboratories or small clinics looking for an economic benchtop autoclave with toploading access. • Sterilization chamber made of AISI-18/10 stainless steel. • Equipment controlled by digital PID microprocessor, cycles adjustable by sterilization...

 Open the catalog to page 6
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-7

THE PERFECT AUTOCLAVE FOR SMALL CLINICS AND RESEARCH FACILITIES LOOKING FOR AN ECONOMIC, VERSATILE AND RELIABLE BENCHTOP AUTOCLAVE WITH A SMALL FOOTPRINT THAT IS COMPATIBLE WITH MULTIPLE APPLICATIONS. INTENDEDUSE • Suitable to sterilize plastics, small metal utensils, laboratory waste bags, culture media, glassware and liquids. • Professional users of small and mediumsized facilities such as small laboratories or small clinics looking for an economic benchtop autoclave with top-loading access. • Sterilization chamber made of AISI-316L stainless steel extremely resistant to corrosion and external...

 Open the catalog to page 7
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-8

Reference CV-8 CV-12 Dimensions Exterior 0 x H mm For autoclaves with the following 8L 1 - FLEXIBLE CORE TEMPERATURE PROBE PT-100 CLASS A • After installing this accessory, the temperature regulation of the sterilization cycle can either be controlled by the main chamber temperature sensor or both the main chamber temperature sensor and the temperature sensor of the flexible core temperature probe. • The temperature control by the flexible core temperature probe is especially advantageous for processes involving the sterilization of large volumes of liquids, where the sterilization process is...

 Open the catalog to page 8
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-9

WATER DISTILLER INTEGRATED THERMAL PRINTER • Prints program number, cycle number, temperature, date and hour of the run and error messages. • Selectable printing cadence between 10 and 240 seconds. • Compatible only with AES-12. • Must be installed in our facilities. Paper: PAPER-IT TABLE TOP DOT MATRIX PRINTER • Prints program number, cycle number, temperature, date and hour of the run and error messages. • Used with RS-232 connection. • Selectable printing cadence between 10 and 240 seconds. • Compatible only with AES-12. Paper: PAPER-ITS, Ribbon: 70945 • Communication software between the...

 Open the catalog to page 9
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-10

TECHNICAL SUMMARY OF AVS-N SERIES AUTOCLAVESAvailable models (fy Sterilization technology features •>)}) Transfer of data [B] Batch printers □] User interface and microprocessor Special cycles and process optimization Adjustable cycle parameters Other specifications Services Recommended setting Equipment placement Load direction Chamber profile Culture media and liquids Laboratory waste bags Porous solids and wrapped loads Glassware Method to generate steam Integrated printer External printer Sterilization chamber volume External building material Sterilization chamber material Heating elements...

 Open the catalog to page 10
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-11

Total/usable volume of the chamber L 8/6,8 15/13 Usable dimensions of the chamber 0 x H mm 220 x 180 250 x 280 Safety features_ • Safety valve. • Safety thermostat with manual rearm for the heating elements. • Pneumatic door blocking system while positive pressure exists inside the sterilization chamber. • Open door sensor (Only AES-12 model). • Thermally insulated door. • Heating elements cover. • Several visual and acoustic safety and warning alarms. General features Available models Adjustable sterilization temperature Adjustable sterilization time Max. pressure Sterilization control system...