1. Catalogs
  2. RaySafe
  3. RaySafe Pro-Digi Radiography Phantom Leaflet

RaySafe Pro-Digi Radiography Phantom Leaflet

RaySafe Pro-Digi Radiography Phantom Leaflet

Product catalog summary
Overview: The RaySafe Pro-Digi Radiography Phantom is designed for acceptance and constancy tests of digital radiography equipment. It is used to measure various parameters critical for radiographic quality assurance.
Specifications:
  • Product Number: 4717397
  • Dimensions: 300 x 300 x 12 mm (12x12x0.47 in.)
  • 1 mm (0.039 in.) thick copper plate embedded in PMMA
  • 7-step copper wedge and 6 low contrast elements
  • 25 mm (0.98 in.) aluminium filter - patient equivalent
Product Features:
  • Complies with DIN 6868-58 and DIN 6868-13 standards
  • Optimized for radiography acceptance and constancy tests
  • Includes markings for determining the size and position of the effective radiation field
  • Pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm)
  • Marks for correct orientation and a cone for perpendicular X-Ray beam control in the range of 0-1.5°
  • Includes holder for chest wall mounting
  • Comes in a robust case with room for all parts
Applications: The phantom is used to measure collimation/beam alignment, dynamic range, spatial and contrast resolution, homogeneity, and beam perpendicularity.
See more

Catalog excerpts

RaySafe Pro-Digi Radiography Phantom Leaflet-1

PRODUCT FEATURES: Complies with: DIN 6868-58 and DIN 6868-13 Optimized for radiography acceptance and constancy tests The RaySafe Pro-Digi Phantom is dedicated for acceptance and constancy tests of digital radiography equipment. It can be used to measure: - Collimation/beam alignment - Dynamic range - Spatial and contrast resolution - Homogeneity - Beam perpedicularity TECHNICAL DATA Product No. 4717397 ■ Dimensions: 300 x 300 x 12 mm (12x12x0.47 in.) ■ 1 mm (0.039 in.) thick copper plate embedded in PMMA ■ 7-step copper wedge ■ 6 low contrast elements ■Free area for signal calibration and dose measurements ■ Markings to determine the size and position of the effective radiation field ■ Pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm) ■ Marks for correct orientation ■ Cone for perpendicular X-Ray beam control in the range of 0-1.5° ■ 25 mm (0.98 in.) aluminium filter - patient equivalent ■ Includes holder for chest wall mounting ■ Comes in a robust case with room for all parts

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.