RaySafe Solo - Specification
5Pages

{{requestButtons}}

Catalog excerpts

RaySafe Solo - Specification - 2

RAYSAFE SOLO GENERAL According to EN 61000-6-1:2007 and EN 61000-6-3:2007 EXPOSURE NEEDED One RESET Automatic TEMP. RANGE 15 – 35 °C (59 – 95 °F) DETECTOR CABLE LENGTH 2 and 10 m (6.5 and 33 ft) PATENT Germany DE69430268.6-08 UK 0758522 Japan 3449721 Sweden 9302909-8 France 075822 USA 5761270 SIZE BASE UNIT 28 x 74 x 142 mm (1.1 x 2.9 x 5.6 in) WEIGHT 250 g (9 oz) POWER OFF Never, or after 5, 20 or 60 min of inactivity POWER SOURCE Rechargeable 7.4 V Li-on battery BATTERY TIME 20 – 40 hours (depending on detector and if Bluetooth is used) READ OUT Three row alphanumerical backlit display...

Open the catalog to page 2
RaySafe Solo - Specification - 3

RAYSAFE SOLO DOSE SIZE DETECTOR WEIGHT DOSE (R/F LOW) RANGE TRIG LEVEL SIZE DETECTOR WEIGHT RANGE TRIG LEVEL UNCERTAINTY DOSE (R/F HIGH) RANGE TRIG LEVEL RANGE MIN. PEAK TRIG LEVEL UNCERTAINTY 10 nGy/s –1 mGy/s (70 µR/min – 7 R/min) MIN. PEAK TRIG LEVEL RANGE MIN. PEAK TRIG LEVEL UNCERTAINTY RANGE UNCERTAINTY PEAK TRIG LEVEL (DENT LOW) PEAK TRIG LEVEL (DENT HIGH) 10 % or ± 0.2 mm Al (at signal levels above 1/1000 of max dose rate for selected sensor) 2 % (for total ltrations from 2.5 mm Al up to 15 mm Al or equivalent, Active Compensation) 0.8 mA, 70 kV, 50 cm (19.7 in), no added ltration 1...

Open the catalog to page 3
RaySafe Solo - Specification - 4

RAYSAFE SOLO LIGHT SIZE DETECTOR RANGE UNCERTAINTY Mo/Mo, Mo/Al, Mo/Rh, Rh/Rh, Rh/Al, W/Rh, W/Ag 5 µGy – 9999 Gy (0.5 mR – 9999R) 10 µGy/s (70 mR/min) 5 % or ± 5 µGy (0.5 mR) (20 – 40 kV: Mo/Mo 22 – 49 kV: Mo/Al, Rh/Rh, Rh/Al 22 – 40 kV: Mo/Rh, W/Rh, W/Ag, 0 – 2.5 mm Al added ltration, Active Compensation) Denition: Paddle = 0.1 mm Al Note! Variation in paddle thickness and homogeneity may affect kV results. To achieve the most accurate result, kV measurements without paddle is recommended. (2) HVL is an option to RaySafe Solo MAM. DOSE BEAM QUALITITES RANGE TRIG LEVEL UNCERTAINTY DOSE RATE...

Open the catalog to page 4
RaySafe Solo - Specification - 5

RAYSAFE UNCERTAINTY DEFINITION Instrument specifications are subject to purchased configuration. T, * . * . , u. * . * c All specifications may change without notice. The expanded uncertainty is stated as the combined uncertainty of measurement multiplied by the coverage factor k=2, which assuming a norma distribution has a coverage probability of 95 % (compiles with GUM by ISO (1995,

Open the catalog to page 5