RaySafe X2 Specifications
8Pages

{{requestButtons}}

Catalog excerpts

RaySafe X2 Specifications - 3

EXPOSURES NEEDED SIZE BASE UNIT WEIGHT BASE UNIT OPERATING TEMPERATURE STORAGE TEMPERATURE POWER SOURCE BATTERY TIME ~ 10 hours intensive usage BATTERY TESTED 4.3” LCD with capacitive touch X2 View for data handling and analysis. Also exports data to Microsoft Excel. PULSE RATE RANGE mAs/PULSE RANGE WAVEFORM RESOLUTION * automatically reduced for exposures longer than 3 s UNFORS RAYSAFE UNCERTAINTY DEFINITION The expanded uncertainty is stated as the combined uncertainty of measurement multiplied by the coverage factor k=2, which assuming a normal distribution has a coverage probability of...

Open the catalog to page 3
RaySafe X2 Specifications - 4

ACTIVE COMPENSATION Beam quality independent for the following ranges: DOSE RATE RESOLUTION 1 nGy/s (5 uR/min) TRIG LEVEL 50 nGy/s (340 uR/min) 10 nGy/s (70 uR/min)xduty cycle MINIMUM DOSE RATE (PEAK) 10 uGy/s (70 mR/min) MINIMUM DOSE RATE (PEAK) 0.5 uGy/s (3.5 mR/mln) at > 70 kV TOTAL FILTRATION MINIMUM DOSE RATE (PEAK) 10 uGy/s (70 mR/min) 'automaticallyadjusted depending on signal level MINIMUM DOSE RATE (PEAK) 0.5 uGy/s (3.5 mR/min) PULSE RATE MINIMUM DOSE RATE (PEAK) 0.5 uGy/s (3.5 mR/min) RANGE 1 nGy/pulse - 999 Gy/pulse MINIMUM DOSE RATE (PEAK) 0.5 uGy/s (3.5 mR/min) BANDWIDTH DOSE...

Open the catalog to page 4
RaySafe X2 Specifications - 5

20 – 50 kVp* Measuring over 40 kVp requires an X2 R/F Sensor + 2 mm Al (incl.) MINIMUM DOSE ACTIVE COMPENSATION Beam quality independent for the following ranges: DOSE/DOSE RATE & HVL No selections needed. With or without paddle, with or without phantom. Mo/Mo, Mo/Rh Mo/Al, W/Rh, W/Ag, W/Al, Rh/Rh, Rh/Al kVp User selectable beam qualities. Paddle compensation available when relevant. W/Ag 20 – 50 kVp Measuring over 40 kVp requires an X2 R/F Sensor + 2 mm Al (incl.) 2 % or 0.5 kV (without paddle) 2 % or 0.7 kV (with paddle) * depending on beam quality, see active compensation HVL RANGE...

Open the catalog to page 5
RaySafe X2 Specifications - 6

X2 LIGHT SENSOR ILLUMINANCE Complies with relevant parts of AAPM TG18, IEC 62563-1 and IEC 61223-2-5. RANGE RESOLUTION MEASUREMENT AREA DEVIATION FROM HUMAN EYE V(λ) (f 1’) < 3 % (see figure Photopic Response) Photopic PhotopicResponse Response Cosine Response Relative Response < 3 % (see figure Cosine Response) APERTURE ANGLE < 3 % (see figure Photopic Response) DEVIATION FROM HUMAN EYE V(λ) (f 1’) RaySafe Response

Open the catalog to page 6
RaySafe X2 Specifications - 7

For measurements in accordance with IEC 60601-2-44 ACTIVE LENGTH ENERGY DEPENDENCE AUTOMATIC ENVIRON80 – 106 kPa, 15 – 35 °C (59 – 95 °F) MENTAL COMPENSATION DOSE RANGE DOSE LENGTH PRODUCT RANGE 100 µGycm – 9999 Gycm (10 mRcm – 9999 Rcm) DOSE RATE RANGE 10 μGy/s – 250 mGy/s (70 mR/min – 1700 R/min) TIME RANGE WAVEFORMS RESOLUTION

Open the catalog to page 7
RaySafe X2 Specifications - 8

Unfors Instruments has changed its name to Unfors RaySafe www.raysafe.com Unfors RaySafe offers comprehensive solutions for the X-ray room to measure the performance of X-ray equipment, to monitor medical staff dose in real-time and to manage X-ray radiation for the benefit of the patient. RaySafe helps you avoid unnecessary radiation.

Open the catalog to page 8