Ocular Response Analyzer® G3

Ocular Response Analyzer® G3
1 / 12 PagesView full catalog

Ocular Response Analyzer® G3

Product catalog summary
Introduction
The document discusses the Reichert Ocular Response Analyzer G3, a device designed to improve glaucoma risk assessment through the measurement of Corneal Hysteresis (CH), a superior predictor of glaucoma progression.

Corneal Hysteresis (CH)
CH is a measure of the cornea's biomechanical properties, differing from thickness or topography. It is a significant predictor of glaucoma progression, with lower CH associated with faster visual field loss. The Ocular Response Analyzer is the only tonometer that measures CH, providing a more reliable assessment of glaucoma risk.

Corneal Compensated Intraocular Pressure (IOPcc)
The device also measures IOPcc, which is less influenced by corneal properties than traditional methods like Goldmann tonometry. This provides a more accurate indication of true intraocular pressure, crucial for glaucoma management.

Clinical Relevance
Studies have shown that CH is more predictive of glaucoma progression than central corneal thickness (CCT). The Ocular Response Analyzer's ability to measure CH and IOPcc makes it an indispensable tool in glaucoma decision-making.

Technological Features
The device features a bi-directional applanation system and a user-friendly interface for quick and simple measurements. It provides a non-contact method, reducing the need for anesthesia and minimizing cross-contamination risks.

Design and Comfort
The Ocular Response Analyzer G3 is designed without a chinrest, enhancing patient comfort and simplifying positioning. Its patented air pulse system customizes pressure for each eye, ensuring maximum comfort.

Regulatory and Historical Context
A new CPT code (92145) was established for CH measurement, reflecting its clinical importance. The document also highlights the historical development of non-contact tonometry by Reichert Technologies.

Specifications
The device specifications include dimensions, weight, voltage, frequency, and measurement range, ensuring compliance with ISO standards.

Conclusion
The Reichert Ocular Response Analyzer G3 represents a significant advancement in glaucoma care, offering reliable, efficient, and patient-friendly measurements of corneal biomechanics.
See more

Catalog excerpts

Ocular Response Analyzer® G3-1

Ocular Response Analyzer® Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression. Advancing Eye Care. American Innovation.

 Open the catalog to page 1
Ocular Response Analyzer® G3-2

Reichert® Ocular Response Analyzer® G3. Make a more confident glaucoma risk assessment, with Corneal Hysteresis. Ocular Response Analyzer® (ORA) is the only tonometer that measures Corneal Hysteresis (CH), a superior predictor of glaucoma progression. Corneal Hysteresis is an indication of the biomechanical properties of the cornea differing from thickness or topography, which are geometrical attributes. “CH measurements were significantly associated with risk of glaucoma progression. Eyes with lower CH had faster rates of visual field loss than those with higher CH.” 1 In addition to Corneal Hysteresis,...

 Open the catalog to page 2
Ocular Response Analyzer® G3-3

Ocular Response Analyzer® G3

 Open the catalog to page 3
Ocular Response Analyzer® G3-4

An indispensable tool in the glaucoma decision making process. Corneal Hysteresis has consistently shown to be predictive of, or strongly associated with, glaucoma progression, and more powerfully so, than key indicators such as IOP and CCT, making it an indispensable tool in the glaucoma decision making process. Glaucoma is the second leading cause of irreversible blindness in the world. Despite the fact that there are a variety of wellknown risk factors, it can be difficult to diagnose. Beyond diagnosing, predicting an individual patient’s rate of future glaucoma progression is often extremely...

 Open the catalog to page 4
Ocular Response Analyzer® G3-5

Corneal Compensated IOP (IOPcc): Less affected by corneal properties. Ocular Response Analyzer takes corneal biomechanical properties into consideration, providing Corneal Compensated IOP (IOPcc). The patented bi-directional applanation system enables the measurement of Corneal Hysteresis and IOPcc. Intraocular pressure (IOP) is the only modifiable risk factor for glaucoma. As such, accurate measurement of IOP is critical for proper diagnosis and management. However, it is widely recognized that Goldmann and other tonometers are influenced by corneal properties. While corneal thickness has been...

 Open the catalog to page 5
Ocular Response Analyzer® G3-6

Corneal Hysteresis is the difference in the inward and outward pressure values obtained during the patented dynamic bi-directional applanation process utilized by the Ocular Response Analyzer. It is a ability to absorb and dissipate energy which is a function of visco-elastic biomechanical Unparalleled user experience. Measurements could not be quicker or simpler with Ocular Response Analyzer G3. A single touch of the intuitive user nterface initiates a fully automated simultaneously displaying Corneal Compensated I0P (lOPcc), Corneal Hysteresis (CH), Goldmann correlated I0P (lOPg), and Waveform...

 Open the catalog to page 6
Ocular Response Analyzer® G3-7

Non-contact saves time and money. Because the Ocular Response Analyzer G3 measurement is rapid and non-contact the use of topical anesthesia and/or fluorescein drops is not required, saving time and money. In addition, the risk of cross contamination is greatly reduced. The need for timeconsuming sterilization of tonometer prisms, costly replacement of prisms, or use of expensive disposables is eliminated. Unique design with patients in mind. Ocular Response Analyzer G3 is designed with no chinrest, which saves time by simplifying patient positioning. This unique design also makes patients more...

 Open the catalog to page 7
Ocular Response Analyzer® G3-8

CPT® Code 92145 published for Corneal Hysteresis. A new CPT code, 92145, has been published specifically for the Corneal Hysteresis measurement provided by the Reichert® Ocular Response Analyzer®. In the 2015 CPT handbook, a new, permanent, Category I CPT code, 92145 (Corneal hysteresis determination, by air impulse stimulation, unilateral or bilateral, with interpretation and report), replaces the prior temporary, Category III CPT code, 0181T. The new code took effect January 1, 2015. For more information regarding CPT Code 92145, please consult your medical billing specialist. Made in the USA....

 Open the catalog to page 8
Ocular Response Analyzer® G3-9

Decades of Glaucoma Care Innovation. In 1959 Dr. Bernard “Bernie” Grolman flipped on the radio during his morning commute to American Optical, now Reichert Technologies, and heard a public service announcement about the prevalence of glaucoma. Being familiar with tonometry due to his industry experience he thought, “What if I could create an instrument that eye doctors could use to help diagnose a leading cause of blindness, without touching the cornea?” “The need for a non-contact tonometer was so obvious,” said Grolman, who would spend the next 10 years of his life designing and testing the...

 Open the catalog to page 9
Ocular Response Analyzer® G3-11

Ocular Response Analyzer G3 Specifications Catalog Number Dimensions Weight Voltage Frequency Measurement Range Communication Port 16170 26.7 W x 50.2 H x 35.6 D cm (10.5 x 19.8 x 14 in.) 10.4 kg (23 lbs) 100/240 VAC 50/60 Hz 7 - 60 mmHg (ISO 8612 tonometer standard) RS-232 1 - Medeiros FA, Meira-Freitas D, Lisboa R, Kuang TM, Zangwill LM, Weinreb RN. Corneal hysteresis as a risk factor for glaucoma progression: a prospective longitudinal study. Ophthalmology. 2013 Aug;120(8):1533-40. 2 - Felipe A. Medeiros, MD and Robert N. Weinreb, MD. Evaluation of the Influence of Corneal Biomechanical Properties...

 Open the catalog to page 11
Ocular Response Analyzer® G3-12

Call Reichert at +1 716-686-4500, toll-free 1-888-849-8955, or contact your Authorized Reichert Technologies Distributor. 3362 Walden Avenue, Depew, NY 14043 USA © 2015 AMETEK, Inc. & Reichert, Inc. 16170-110-Rev B Auto Tonometer + Corneal Hysteresis Ocular Response Analyzer® G3

 Open the catalog to page 12

All Reichert catalogs and technical brochures

  1. Tono-Vera®

    8  Pages

  2. Phoroptor® VRx

    12  Pages

Archived catalogs

  1. ML1

    2  Pages

  2. Tono-Pen®

    10  Pages

  3. TONO-PEN VET?

    2  Pages

  4. AP250

    2  Pages

  5. Reflex

    2  Pages

  6. AL700

    2  Pages

  7. Phoroptor®

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.