Ocular Response Analyzer - 1

Ocular Response Analyzer® The world's only direct measure of Corneal Biomechanical tissue properties. ULTRA PRECISION TECHNOLOGIES Advancing Eye Care. Preserving Sight."

Open the catalog to page 1
Ocular Response Analyzer - 2

Reichert® is Corneal Biomechanics. Reichert Technologies® pioneered the measurement of corneal biomechanical properties with the development of “Corneal Hysteresis” and Corneal Compensated IOP (IOPcc). Since the introduction of the Ocular Response Analyzer® in 2005, Reichert has continued to define the ocular biomechanics revolution. We are now pleased to announce the next generation Ocular Response Analyzer. (his ´ te re¯ ´ sis), n., [NL, fr. Gk hystére¯sis shortcoming, fr. hysterein to be late, fall short, fr. hysteros later] - a retardation of effect when forces acting upon a body are...

Open the catalog to page 2
Ocular Response Analyzer - 3

How it Works. The Ocular Response Analyzer utilizes a dynamic bi-directional applanation process to measure biomechanical properties of the cornea and the intraocular pressure of the eye. A precisely metered collimated air-pulse causes the cornea to move inwards, past applanation, and into a slight concavity. Milliseconds after applanation, as the air pulse force decreases, the cornea begins to return to its normal configuration. In the process, it once again passes through an applanated state. An electro-optical system monitors the curvature of the cornea throughout the deformation process...

Open the catalog to page 3
Ocular Response Analyzer - 4

Ocular Response Analyzer® Corneal Biomechanics & Accurate IOP Ocular Response Analyzer: At a Glance • bjective measurements – no operator influence O Catalog Number: 16070 Ocular Response Analyzer 16071 Ocular Response Analyzer w/ chinrest • omprehensive patient management database C • mproved measurement repeatability I Tonometer Measurement Range: 0 - 60 mmHg Tonometer Display Resolution: ± 0.10 mmHg • ofter, quieter air-puff S Note: The accuracy complies with ISO 8612 Tonometer Standard • x faster automated alignment and measurement 2 Device Computer: Internal CPU 160GB hard drive...