Introduction
The TONO-PEN AVIA VET™ is a veterinary tonometer specifically designed for measuring intraocular pressure (IOP) in animals. It is intended for use by trained veterinary professionals and is not approved for human use.
Warnings and Cautions
To ensure safe and accurate use, the device must be used with an OCU-FILM® tip cover to prevent inaccurate readings and potential corneal abrasions. Users should avoid applying excessive pressure and ensure the device is not modified without authorization. The device should be handled carefully to avoid damage and should not be exposed to high temperatures or electromagnetic interference.
General Overview
The device includes a sensor tip, transducer assembly, LCD display, LED indicator, power supply, and activation button. It operates in several modes: Power Up, Applanation, Verification, and Sleep Mode.
Device Modes
Power Up Mode: Initiates self-tests and prepares the device for use.
Applanation Mode: Allows for IOP measurement within a 15-second window.
Verification Mode: Ensures the device is functioning correctly.
Sleep Mode: Activates after 25 seconds of inactivity to save power.
Verification Procedure
If suspect readings occur, a verification procedure should be conducted by holding the device in specific orientations and listening for audio cues to ensure accuracy.
Battery Installation and Replacement
The device uses a TONO-PEN AVIA VET POWERCEL® battery pack. Proper installation involves inserting the battery pack and checking the LCD for battery status.
Performing IOP Measurements
A topical anesthetic should be applied to the animal's eye before measurement. The device should be held like a pencil, and the sensor lightly tapped on the corneal surface. The device will chirp for each valid reading, and a beep will indicate completion.
Maintenance and Storage
Regular cleaning of the tonometer tip is necessary to ensure accurate readings. The device should be stored with an OCU-FILM tip cover to protect it from contaminants. It should not be immersed in fluids or sterilized.
Troubleshooting
Common issues include failure in verification procedures, often due to debris around the sensor tip. Cleaning instructions are provided in the maintenance section.
Specifications
The device meets ISO 9001/13485 standards, ensuring quality manufacturing processes. It lists physical dimensions, environmental requirements, IOP measurement range, and electrical specifications. It also complies with electromagnetic emissions and immunity standards.
Guidance and Compliance
The device is designed to operate in specific electromagnetic environments, with guidelines for maintaining appropriate distances from RF communications equipment to prevent interference.
Warranty
Reichert, Inc. offers a one-year warranty against defects in material and workmanship, with specific conditions and exclusions outlined.
Customer Service
Contact information for technical support is provided, emphasizing the need for product details when seeking assistance.
See more

Catalog excerpts

TONO-PEN AVIA VET ?-1

TONO-PEN AVIA VET™ Veterinary Tonometer User's Guide

 Open the catalog to page 1
TONO-PEN AVIA VET ?-2

The following are registered trademarks of Reichert, Inc. Reichert ® TONO-PEN AVIA VET™ TONO-PEN AVIA VET POWERCEL® OCU-FILM® ©2012 Reichert, Inc. The information contained in this document was accurate at time of publication. Reichert, Inc. reserves the right to make changes in the product described in this manual without notice and without incorporating those changes in any products already sold. ISO 9001/13485 Certified – Reichert products are designed and manufactured under quality processes meeting ISO 9001/13485 requirements. Caution: Federal law restricts this device to sale by or on the...

 Open the catalog to page 2
TONO-PEN AVIA VET ?-3

TONO-PENAVIA VET Tonometer Modes 9 TONO-PENAVIA VET Tonometer Tones 11 Battery Pack Installation and Replacement 12 Liquid Crystal Display (User Interface) 13 TONO-PEN AVIA VET Tonometer Preparation 15 Guidance & Manufacturer's Declaration 24 Customer Service Information 28

 Open the catalog to page 3
TONO-PEN AVIA VET ?-4

The TONO-PEN AVIA® VET tonometer is a prescription only device intended for measuring intraocular pressure (IOP) during routine eye examinations or when increased intraocular pressure is suspected by properly trained eyecare professionals such as veterinarians, and veterinary technicians. Note: The TONO-PEN AVIA VET is not approved for use on humans. The indications for use include measuring intraocular pressure (IOP) for suspected glaucoma, or when increased intraocular pressure is suspected. CONTRAINDICATIONS None. DEVICE DESCRIPTION The TONO-PEN AVIA VET tonometer is an ergonomic, handheld...

 Open the catalog to page 4
TONO-PEN AVIA VET ?-5

Introduction (continued) This User’s Guide is designed as a training and reference manual for operation, maintenance, and troubleshooting. We recommend that you read it carefully prior to use and follow the instructions in the guide to ensure optimum performance of your new instrument. If used properly, the TONO-PEN AVIA VET tonometer will provide you with fast, accurate and reliable measurements for many years. Please retain this manual for future reference and to share with other users. Additional copies can be obtained from the Reichert Customer Service Department. Contact information is provided...

 Open the catalog to page 5
TONO-PEN AVIA VET ?-6

Warnings and Cautions WARNING: An instruction that draws attention to risk of injury or death. WARNING: Any repair or service to this instrument must be performed by experienced personnel or dealers who are trained by Reichert so that correct operation of this instrument is maintained. WARNING: Modifications to this instrument is not allowed. Any modification to this unit must be authorized by Reichert so that correct operation is maintained. WARNING: If this instrument is modified, appropriate inspection and testing must be conducted to ensure continued safe use of this instrument. WARNING:...

 Open the catalog to page 6
TONO-PEN AVIA VET ?-7

Warnings and Cautions (continued) CAUTION: Do not touch the sensor without an OCU-FILM tip cover applied or damage to the sensor and transducer assembly may result. CAUTION: Do not bump, jar or drop the device, or damage to the electronics may occur. CAUTION: Do not immerse the TONO-PEN AVIA VET tonometer in fluids or damage to the electronics may occur. CAUTION: Do not attempt to sterilize the TONO-PEN AVIA VET tonometer or damage to the electronics may occur. CAUTION: Do not attempt to modify the TONO-PEN AVIA VET tonometer or the TONO-PEN AVIA VET POWERCEL battery pack or damage to the device...

 Open the catalog to page 7
TONO-PEN AVIA VET ?-8

General Overview PRIMARY COMPONENTS AND CONTROLS A. Tip – location of sensor. B. Transducer Assembly - housing for sensor. C. LCD - displays the IOP in mmHg, number of applanations collected, statistical confidence indicator, and battery. life status D. LED - green light on in Applanation Mode. E. Power Supply - TONO-PEN AVIA VET POWERCEL battery pack. F. Activation Button - Applanation Mode select button.

 Open the catalog to page 8
TONO-PEN AVIA VET ?-9

TONO-PEN AVIA VET Tonometer Modes POWER UP MODE Pressing the activation button initiates the battery life, LCD, sensor, and electronic self-test. A successful power-up puts the device automatically into applanation mode. APPLANATION MODE A 15 second interval within which the user should complete the 6 applanations needed to acquire an IOP value. During applanation mode, the LCD will display the IOP and number of applanations collected. After 6 applanations are collected, the LCD will display the average IOP along with a statistical confidence indicator. After 25 seconds, the device will automatically...

 Open the catalog to page 9
TONO-PEN AVIA VET ?-10

TONO-PEN AVIA VET VERIFICATION If suspect readings are observed, a Verification Procedure routine should be performed. This will ensure that the sensor and electronics are performing correctly. VERIFICATION PROCEDURE • Hold the TONO-PEN AVIA VET tonometer with the sensor end pointing down towards the floor. • • • • • • • Press and hold the activation button for 5 seconds a beep will sound at one second intervals. At the end of the 5 second button hold, the display will show “dn”. Keep the pen vertical, with the sensor tip pointing down towards the floor, for a total of 15 seconds. At the end...

 Open the catalog to page 10
TONO-PEN AVIA VET ?-11

TONO-PEN AVIA VET Tonometer Tones The TONO-PEN AVIA VET tonometer generates two different tones. A “BEEP” will sound when: • • • • • • Power Up Mode fails Verification Procedure fails Applanation Mode starts IOP testing is completed IOP values are out of range ( >99mhg) At various points during the Verification Procedure. A “CHIRP” will sound when: • A valid IOP measurement has been taken during applanation.

 Open the catalog to page 11
TONO-PEN AVIA VET ?-12

Battery Pack Installation and Replacement The TONO-PEN AVIA VET tonometer is supplied with a TONO-PEN AVIA VET POWERCEL battery pack that needs to be installed prior to use. The TONO-PEN AVIA VET POWERCEL battery pack is the only replacement battery that can be used with this device. 1. Insert the TONO-PEN AVIA VET POWERCEL battery pack into the base of TONO-PEN AVIA VET tonometer until fully seated. The battery pack is “keyed” for correct installation. 2. Press the Activation Button. 3. Check that the battery symbol in the LCD has all segments displayed. 4. Check that the Self-Test is initiated....

 Open the catalog to page 12

All Reichert catalogs and technical brochures

  1. Tono-Vera®

    8  Pages

  2. Phoroptor® VRx

    12  Pages

Archived catalogs

  1. ML1

    2  Pages

  2. Tono-Pen®

    10  Pages

  3. TONO-PEN VET?

    2  Pages

  4. AP250

    2  Pages

  5. Reflex

    2  Pages

  6. AL700

    2  Pages

  7. Phoroptor®

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.