Product Overview
The MAVERICK® System is designed for monitoring mammalian cell cultures, specifically in CHO or HEK293 media. It provides analytical performance with a measurement/reporting period of once per minute.
Analytical Performance
  • Glucose Measurement: Range of 0 to 10 g/L with a precision of approximately 0.1 g/L.
  • Lactate Measurement: Range of 0 to 5 g/L with a precision of approximately 0.1 g/L.
  • Total Biomass Measurement: Equivalent of 0 to 25 x 106 cells/mL.
Hub Specifications
  • Supports 6 measurement module connections with power and data over Ethernet.
  • Features a 25.4 cm touch screen user interface.
  • Data export available in XLSX or CSV format via USB-C, USB-A, or LAN.
  • Uses OPC UA digital communication protocol and Ethernet networking.
  • Dimensions: 21 cm x 26 cm x 17 cm; Weight: 2 kg.
  • Power requirements: 120/240 VAC, 50/60 Hz.
  • Ingress protection rating: IP 5X.
  • Operating temperature range: 15°C to 25°C; Humidity range: 20-80% RH (non-condensing).
  • Software compliant with GAMP 5 Category 3 guidelines and CFR 21 part 11.
Measurement Module Specifications
  • Excitation wavelength: 785 nm; Laser output power: ~450 mW.
  • Spectral range: 200 cm-1 to 3,200 cm-1; Resolution: ~6 cm-1.
  • Fiber optic cable length: 200 cm.
  • Power requirements: 40 W POE supplied by Hub.
  • Ingress protection rating: IP 5X; Laser classification: Class 3B.
  • Analog outputs: Two channel analog (4–20 mA or 0–10 V).
  • Dimensions: 20 cm x 26 cm x 8 cm; Weight: 2 kg.
  • Operating temperature range: 15°C to 25°C; Humidity range: 20-80% RH (non-condensing).
Immersion Probe Specifications
  • Probe dimensions: 220 mm length, 12 mm diameter.
  • Minimum reactor wall clearance: 40 mm.
  • Bioreactor connection: Compression fitting, 12 mm I.D., PG-13.5 thread.
  • Compatible with autoclave or steam sterilization; Max sterilization temperature and pressure: 121°C, 15 psi.
  • Wetted materials include 316 L stainless steel, sapphire, EPDM, and ISO: 10993 certified lubricant.
Contact Information
Repligen Corporation, 685 Route 202/206, Bridgewater, NJ, USA 08807
Email: [email protected]
Phone: (908) 707-1009
See more

Catalog excerpts

MAVERICK® In-line System Specification Sheet-1

MAVERICK® System Product Specifications Data Specification Sheet Intended Applications Monitoring of mammalian cell cultures in CHO or HEK293 media Analytical Performance Measurement/reporting period Glucose Units of measurement Measurement range Measurement precision Lactate Units of measurement Measurement range Measurement precision Total Biomass Units of measurement Biomass units (BMUs) Measurement range Immersion Probe Measurement Module repligen.com © 2025 Repligen Corporation. All rights reserved. The trademarks mentioned herein are the property of Repligen Corporation and/or its affiliate(s) or their respective owners. | DOC0420 eRev. 1.0 11 Jun 2025

 Open the catalog to page 1
MAVERICK® In-line System Specification Sheet-2

MAVERICK® System Data Specification Sheet Measurement module connections 6 with power and data over ethernet User interface 25.4 cm touch screen Data export XLSX or CSV format via USB-C or USB-A port or over LAN Digital communication protocol OPC UA Networking Ethernet Ingress protection rating IP 5X Operating temperature range 15°C to 25°C Operating humidity range 20-80% RH (non-condensing) Software In accordance with GAMP 5 Category 3 guidelines and CFR 21 part 11 compliance ready

 Open the catalog to page 2
MAVERICK® In-line System Specification Sheet-3

MAVERICK® System Data Specification Sheet Measurement Module Excitation wavelength Laser output power Approximately 450 mW (strictly less than 500 mW) Spectral range Spectral resolution Fiber optic cable length Power requirements 40 W power over ethernet (POE) supplied by Hub Integrated controllers Hysteresis controller with configurable analog output Ingress protection rating Laser classification Class 3B laser; NOHD 10 cm from probe tip (equivalent to Class 1 beyond 10 cm) Analog outputs Operating temperature range Operating humidity range

 Open the catalog to page 3
MAVERICK® In-line System Specification Sheet-4

MAVERICK® System Data Specification Sheet Immersion Probe Probe length and outside diameter Minimum reactor wall clearance Bioreactor connection Compression fitting; 12 mm I.D.; PG-13.5 thread Compatible sterilization methods Autoclave or steam sterilization Maximum recommended sterilization temperature and pressure Wetted materials 316 L stainless steel with Ra 15 µin Electro-polish surface finish, sapphire, EPDM, and Bio-compatible ISO: 10993 certified lubricant Contact Repligen Corporation 685 Route 202/206 Bridgewater, NJ, USA 08807 [email protected] (908) 707-1009 repligen.com...

 Open the catalog to page 4

Archived catalogs

  1. FlowVPE

    1  Page

  2. SoloVPE

    9  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.