Overview
The PATsmart™ SoloVPE® PLUS System is an advanced version of the SoloVPE System, designed for faster performance and a broader concentration measurement range without dilution. It utilizes Variable Pathlength Technology (VPT) and Slope Spectroscopy® to provide rapid, accurate concentration measurements in under a minute, covering wavelengths from 190 nm to 1100 nm and pathlengths from 0.002 mm to 15.000 mm.
Features and Benefits
  • No Dilution: Direct measurement of highly concentrated samples.
  • Eliminate Background Correction: Only needed in special cases.
  • Rapid Results: Results typically in less than 1 minute.
  • Low Sample Volume: Requires <20 µL to 2.5 mL depending on method.
  • Slope Spectroscopy Method: Utilizes multiple data points for quantitation without a reference standard.
  • Linear Range-Finder Technology: Automatically verifies compliance with the Beer-Lambert law.
  • Easy-to-use Software: Includes applications for ADC, AAV, & Nucleic Acids with built-in calculations.
  • GMP Ready: Software supports compliance with 21 CFR Part 11 and EU Annex 11.
  • Education/Support: On-site installation and training included.
System Specifications
  • Dimensions: 257 × 245 × 464 mm
  • Weight: 9 kg
  • Spectroscopic Engine: Agilent Cary 60 Spectrophotometer
  • Power Requirements: 100–240 VAC, 47–63 Hz
  • Operating Conditions: 5°C to 38°C, 15% to 80% relative humidity
  • Maximum Pathlength: 15.000 mm
  • Slope Repeatability: ≤2% RSD
  • Sample Vessel Compatibility: Fused silica and disposable plastic
Customer Service and Support
Repligen offers comprehensive support including IQOQ, a 12-month warranty, and training. Service contracts are available for extended support. Contact Repligen for more information on application suitability and limitations.
See more

Catalog excerpts

PATsmart™ SoloVPE® PLUS At-line System Specification Sheet-1

PATsmart™ SoloVPE® PLUS System Product Specifications Specification Sheet Part ID: SYS-SOLO-P-VP-CARY60-CMP SYS-SOLO-P-VP-CARY60-CMP-CN (China) SYS-SOLO-P-VP-CARY60-CMP-JP (Japan) Overview The PATsmart™ SoloVPE® PLUS System is an enhanced version of the SoloVPE System, offering faster performance and an extended concentration measurement range without the need for dilution. Building on our unique and patented Variable Pathlength Technology (VPT), the SoloVPE PLUS System elevates the user’s experience with time savings and ease of use while maintaining the high accuracy and precision valued by leading biologic manufacturing companies for rapid at-line concentration measurement. Unlike traditional UV-Vis methods that generate a single absorbance result, the Slope Spectroscopy® method characterizes samples using multiple absorbance data points acquired at different pathlengths. The absorbance vs. pathlength data are verified in real-time for linearity in compliance with the Beer-Lambert law. The slope of the line is directly proportional to the sample concentration and extinction coefficient, delivering results in under a minute without the need for dilution or background correction. The SoloVPE PLUS System measures wavelengths from 190 nm to 1100 nm and pathlengths from 0.002 mm to 15.000 mm, accommodating various sample types and concentrations with proven accuracy and repeatability across systems, operators, and sites. Invest in the SoloVPE PLUS System to future-proof your lab, expand your capabilities, and stay at the forefront of analytical technology. repligen.com © 2026 Repligen Corporation. All rights reserved. The trademarks mentioned herein are the property of Repligen Corporation and/or its affiliate(s) or their respective owners. | DOC0361 eRev. 4.0 21 J

 Open the catalog to page 1
PATsmart™ SoloVPE® PLUS At-line System Specification Sheet-2

Specification Sheet PATsmart™ SoloVPE® PLUS System Features | Benefits *Photometric performance characteristics are based upon the Cary 60 spectrophotometer specifications and are applicable to the Cary 60 independent of the SoloVPE PLUS instrument. f Repeatability performance requires a properly validated method and controlled homogeneous samples. tSamples that are not homogeneous, suspensions, improperly mixed, or not in solution could produce unexpected results. This should be assessed during method development.

 Open the catalog to page 2
PATsmart™ SoloVPE® PLUS At-line System Specification Sheet-3

Specification Sheet PATsmart™ SoloVPE® PLUS System Required Computer Hardware Hard drive: 250 GB (SSD preferred) Final application suitability of all materials and ratings are the sole responsibility of the user. Specified pressure and temperature ratings may be subject to limitations. Contact a Repligen analytical representative for more information. More information Repligen Corporation and/or its affiliates, to the extent allowed by law, disclaims, and in no event shall be liable for, any incidental or consequential damages in connection with user, instrument, or system performance in relation...

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.