MicroBeta2 microplate counters
4Pages

{{requestButtons}}

Catalog excerpts

MicroBeta2 microplate counters - 1

Description MicroBeta2® microplate counters measure radioactivity, as well as luminescence. These instruments are available in 1-, 2-, 6-, and 12-detector configurations with 16-shelf loading capacity. A robotic loading option allows efficient integration into robotics systems. Each instrument model also supports different plate matrices and is capable of running samples in either “96‑well + 384-well plate” format or in “96-well + 24-well plate” format. The samples can be contained on microtiter plates, 4-mL vials, Eppendorf® tubes, or on filtermats. Standard features for MicroBeta2 plate counters Hardware MicroBeta2 • 1, 2, 6, or 12 detectors • 1- and 2-detector systems run 24- and 96-well plates, 6- and 12-detector systems run 96- and 384-well plates, 6-detector systems can be configured to count 24- and 96-well plates (optional) • Sample types for radioactivity: • Liquid scintillation counting in microtiter plates • Filterplates, e.g. UniFilter® Plates • Filtermats • FlashPlates® • Solid scintillator, e.g. MeltiLex® •

Open the catalog to page 1
MicroBeta2 microplate counters - 2

• Sample types for luminescence: • Microtiter plates, e.g. OptiPlate™ or CulturPlate™ • Counting modes include single- and dual-label CPM, single- and dual-label DPM, ParaLux™ count mode, and luminescence counting. • Proprietary Time-Resolved Liquid Scintillation Counting (TR-LSC) mode significantly improves counting capabilities with opaque plates and low-energy isotopes. TR-LSC mode can generate close to dual-PMT coincidence counting performance by using top PMTs only. • Unique detector design consists of two photomultiplier tubes (PMT). One is located below the sample, the other above...

Open the catalog to page 2
MicroBeta2 microplate counters - 3

• Up to 100 quench corrections can be performed and linked into 100 counting protocols. Quench corrections will also include detector efficiency corrections, background corrections, and crosstalk corrections. • Password protection for counting, normalization, and quench correction protocols are included. Analysis • Three counting windows allow the analysis of the signal in three independent counting regions. • Background subtraction enables fixed samples or values obtained from detector normalization to be used for calculations. • Half-life correction is a correction facility for CPM and...

Open the catalog to page 3
MicroBeta2 microplate counters - 4

Electrical Requirements: Main Voltage 100, 115, 120, 240 V +/- 10% Frequency 50/60 Hz Power Consumption 360 VA max Safety, radiated emissions, and immunity: MicroBeta2 has been tested and approved for electrical safety, radiated emissions, and electromagnetic compatibility. In the USA, the CSA approval also satisfies the requirements of 29CFR 1910.399. MicroBeta2 fulfills the requirements of the following standards: • MicroBeta2 conforms to the following EU directives: CE marking: • Revvity, Inc. 940 Winter Street Waltham, MA 02451 USA www.revvity.com For a complete listing of our global...

Open the catalog to page 4