Overview: The Omicrom VISION v7-S is a comprehensive medical monitoring device designed for various vital sign measurements including respiration, pulse oximetry, ECG, non-invasive and invasive blood pressure, capnography, and temperature. It features a thermal printer and arrhythmia detection capabilities.
Specifications:
  • Dimensions: 310 (W) x 210 (L) x 260 (H) mm
  • Weight: 7 kg
  • Power Supply: 85-264 V; 47-63 Hz, AC input power: 45 to 100 VA
  • Battery: 4 hours autonomy with built-in charger
  • Operating Temperature: 0 ºC to 40 ºC; 32 ºF to 104 ºF
  • Relative Humidity: 5% to 90% non-condensing
Measurement Capabilities:
  • Non-Invasive Blood Pressure (NIBP): Uses oscillometric method with different cuff sizes. Measurement range is 10 to 250 mmHg with an overpressure limit of 300 mmHg for adults and 150 mmHg for neonates.
  • Pulse Oximetry (SpO2): Range of 0 to 100% with accuracy of ±2% for 70 to 100% saturation.
  • ECG: 7-lead ECG with arrhythmia detection including asystolia, ventricular tachycardia, and more. Display features a 10.4-inch TFT color screen.
  • Temperature: Measurement range of 15 to 45 ºC with accuracy of ±0.1 ºC using oesophageal, rectal, or skin probes.
  • Capnography (CO2): Sidestream module with a range of 0 to 150 mmHg and typical accuracy of ±2 mmHg for 0 to 40 mmHg.
Safety and Standards: Complies with IEC 601 standards, fully isolated and defibrillator protected > 5 kV. Patient leakage current is <100 µA.
Additional Features:
  • Automatic rejection against ESIS through real-time signal analysis.
  • Optical and acoustic alarms with three priority levels.
  • Trends display for up to 72 hours with graphical and tabular formats.
Ordering Information: Various accessories available including temperature probes, NIBP cuffs, ECG cables, and SpO2 sensors.
See more

Catalog excerpts

Brochure VISION v 7-1

NIBP Non Invasive Blood Pressure ARRHYTHMIA Detection: Asystolia, Ventricular Tachycardia, Bigeminy, Ventricular Rhythm, Couple of PVC, Trigeminy, Run of PVC, Tachycardia, Bradycardia. INVASIVE BLOOD PRESSURE (2) CO2 Capnography Sidestream module THERMAL PRINTER

 Open the catalog to page 1
Brochure VISION v 7-2

Omicrom® Vision Technical Data ECG Amplifier: Fully isolated, defibrillator protected > 5 kV; recovery time < 5 s; RF noise and monitoring filters. Leads: I, II, III, V, aVL, aVF, aVR. Freeze and memory: ST Segment. Frozen ECG, 12 seconds for analysis and measurement. Heart rate: Range: 20 to 300 bpm Accuracy: ±2 % CMRR: > 115 dB in monitor mode > 90 dB in diagnostic mode Signal features: Diagnostic mode: 0.05 to 100 Hz Monitor mode: 0.5 to 25 Hz O. R. mode: 0.5 to 25 Hz Programmable gain: 1 to 8 mV Pacemaker detection and rejection: Pulse duration: 0.1 to 2 ms Pulse amplitude: ±2 to ±700 mV...