1. Catalogs
  2. RIGEL Medical
  3. Rigel 288 Electrical Safety Analyzer

Rigel 288 Electrical Safety Analyzer

Rigel 288 Electrical Safety Analyzer

Rigel 288 Electrical Safety Analyzer

Product catalog summary
Overview
The Rigel 288 is a hand-held medical electrical safety tester designed for both automatic and manual testing, combined with data logging and asset management capabilities. It is compact, lightweight, and battery-powered, making it suitable for multi-site use. The device supports testing standards including IEC 60601-1, AAMI/NFPA 99, and the newer IEC 62353 for in-service and post-repair testing of medical electronic devices.
Key Features
  • Versatile Testing: Complies with IEC/EN 62353, IEC/EN 60601-1, AAMI, NFPA, AS/NZS 3551, and VDE 0751-1 standards.
  • Hand-held Design: Robust and easy to operate single-handedly.
  • Display and Interface: Features a full graphic monochrome LCD display with an alphanumeric keyboard.
  • Test Modes: Supports fully automatic, semi-automatic, and manual testing modes.
  • Custom Test Routines: Users can create or modify test sequences to suit specific needs.
  • Data Management: Stores up to 10,000 test records and supports Bluetooth data transfer to PCs.
Market Context
The introduction of the IEC 62353 standard has shifted the market for medical safety testers, with many manufacturers adopting it for routine testing. The Rigel 288 is the first hand-held tester to integrate graphics, an alphanumeric keyboard, and Bluetooth connectivity, enhancing field flexibility.
Custom Test Settings
The Rigel 288 allows configuration of test sequences and visual or acceptance test routines. It supports post-safety test procedures, capturing comprehensive test data in a single record for enhanced traceability.
Test ‘n’ Tag System
The Rigel Test ‘n’ Tag system enables the printing of customized thermal PASS/FAIL labels, which are durable and resistant to solvents. It supports barcode generation for efficient testing.
Med-eBase PC Software
Compatible with Med-eBase software for asset management and work scheduling. It allows configuration of multiple Rigel 288 units and supports test protocol uploads via Bluetooth or RS 232.
Specifications
  • Earth Continuity: Uses a 2-wire technique with a test current of >200mA DC.
  • Insulation Resistance: Measures EUT to Earth/Ground with a voltage of 250V DC or 500V DC.
  • Leakage Measurements: Supports direct, differential, and alternative leakage measurements with true RMS.
  • Power Measurement: VA rating method with a range of 0.1KVA to 4KVA.
Design Philosophy
The Rigel 288 addresses the demand for compact, comprehensive test equipment in healthcare, combining portability with the capabilities of larger bench-mounted analysers. It is designed to save time and cost while meeting IEC 60601 and IEC 62353 standards.
Additional Information
Includes a variety of accessories and is compatible with other Rigel and Seaward Group testing equipment. The Rigel 288 is positioned as a new standard in electrical medical safety testing.
See more

Catalog excerpts

Rigel 288 Electrical Safety Analyzer-1

288 Electrical Medical Safety Analyser Technical Data Sheet 2009 Tried. Tested. Trusted.

 Open the catalog to page 1
Rigel 288 Electrical Safety Analyzer-2

Tried. Tested. Trusted. The Rigel 288 is a hand-held medical electrical safety tester to combine an automatic / manual tester with a data logging / asset management facility. The Rigel 288’s compact lightweight design and long life battery power reduces downtime between tests, making the instrument practical and highly portable for multi site use. In addition to IEC 60601-1 and AAMI / NFPA changed. The globally recognised IEC 62353 for in-service and after repair testing of has become the general guideline for routine medical electronic devices, the testing for many leading medical device manufacturers....

 Open the catalog to page 2
Rigel 288 Electrical Safety Analyzer-3

Tried. Tested. Trusted. electrical safety test. These could be simple The unique Test ‘n’ Tag label enables test instructions to the user or observations status and retest due date, barcode and required for your own maintenance asset ID number, and person conducting procedures such as checking for certain labels, software versions and upgrades etc. Applications ■ Routine testing of Medical Electrical Equipment ■ Service tool for Performance Testing In addition, you can configure post safety test procedures such as recording readings during The Rigel 288 is compatible with Med-eBase, a performance...

 Open the catalog to page 3
Rigel 288 Electrical Safety Analyzer-4

Tried. Tested. Trusted. 3. Upload from PC to Rigel 288 via Bluetooth or RS 232 4. Create test routines and configure multiple testers Seaward Group files patent for new Earth Continuity test Seaward Group, parent company of Rigel Medical, has developed a new method of 5. Output of database to Excel / Access. carrying out earth continuity tests undertaken as part of the process to verify the electrical 7. Test schedule function safety of portable medical and domestic 8. Printing of test certificate 9. Store test certificate as HTML for easy The Seaward Group has filed a patent email application...

 Open the catalog to page 4
Rigel 288 Electrical Safety Analyzer-5

Tried. Tested. Trusted. SPECIFICATIONS Additional Information Unique use of Icons Earth Continuity Method 2 wire technique, using 'zero' lead function. Test Current Measuring Range (low range) 0.001 – 0.999 ohms @ 0.001 ohms resolution Measuring Range (mid range) 1.00 – 9.99 ohms /@ 0.01 ohms resolution Measuring Range (high range) 10.0 – 19.9 ohms @ 0.1 ohms resolution The Rigel 288 features a hi-resolution graphic backlit display which not only provides highly visible and easy to follow menu structures but also allows the user to operate the tester using intuitive icons to speed up their test...

 Open the catalog to page 5
Rigel 288 Electrical Safety Analyzer-6

Tried. Tested. Trusted. Power Measurement Method Range Also available Mains Outlet Test Input voltage range: ■ PC Download software ■ Barcode scanner with embedded Bluetooth ■ Bluetooth Test ‘n’ Tag System ■ Bluetooth results printer ■ Bluetooth Serial Adaptor ■ Pelican case IEC Mains Lead Test Test Duration: From Rigel Medical Continuity of all conductors, Earth bond, Insulation & Polarity General Rigel 266 Plus Manual Safety Analyser Rigel 277 Plus Automatic Safety Analyser Rigel BP-Sim NIBP Simulator Rigel SP-Sim SPO2 Simulator Rigel 333 Patient Simulator Rigel 344 Defibrillator Tester Rigel...

 Open the catalog to page 6

All RIGEL Medical catalogs and technical brochures

  1. Med-eBase

    2  Pages

  2. SafeTest 60

    3  Pages

  3. CITREX H3

    1  Page

  4. SafeTest 99

    3  Pages

  5. CITREX H5

    2  Pages

  6. IEC 62353

    29  Pages

  7. IEC 60601

    18  Pages

  8. Global Brochure

    17  Pages

  9. CITREX

    6  Pages

  10. Rigel 62353+

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.