Tried. Tested. Trusted. The Rigel 62353 is a hand-held medical electrical safety tester to combine an automatic / manual tester with a data logging / asset management facility. The Rigel 62353’s compact lightweight design and long life battery power reduces downtime between tests, making the instrument practical and highly portable for multi-site use. The Rigel 62353 tests to the new standard for hand-held medical safety testers has in-service and after repair testing of medical changed. The globally recognised IEC 62353 has become the general guideline for routine The Rigel 62353’s large...
Open the catalog to page 2
Tried. Tested. Trusted. Trusted. Tried. Tested. Tried. Tested . Trusted. uide tical g A Pra A Prac 2353 ctical g uide to IEc 6 to IEc 62353 includes a unique feature to allow visual or Create customer test routines including test acceptance test routines to be configured protocols for testing patient monitors (NIBP, prior to an electrical safety test. These could be simple instructions to the user or protocols can be easily uploaded to the observations required for your own maintenance procedures such as checking Use the Rigel 62353 during functional for certain labels, software versions...
Open the catalog to page 3
Tried. Tested. Trusted. Rigel 62353 Design Philosophy domestic appliances. The Rigel 62353 has been designed to The Seaward Group has filed a patent address the increasing demand for smaller application for the new test technology that more comprehensive test equipment within uses a dual current high intensity test to the healthcare industry. What better way than overcome contact resistance problems or to combine such a tester with the other situations where weak conductor International In-Service Test required as per connections may inhibit protective earth testing with conventional test...
Open the catalog to page 4
Tried. Tested. Trusted. SPECIFICATIONS Additional Information Unique use of Icons Earth Continuity Method 2 wire technique, using 'zero' lead function. Test Current Measuring Range (low range) 0.001 – 0.999 ohms @ 0.001 ohms resolution Measuring Range (mid range) 1.00 – 9.99 ohms /@ 0.01 ohms resolution Measuring Range (high range) 10.0 – 19.9 ohms @ 0.1 ohms resolution The Rigel 62353 features a hi-resolution graphic backlit display which not only provides highly visible and easy to follow menu structures but also allows the user to operate the tester using intuitive icons to speed up...
Open the catalog to page 5
Tried. Tested. Trusted Also available Power Measurement Mains Outlet Test Input voltage range: I EC Mains Lead Test Test Duration: Mains power Operating conditions Storage environment Environmental Protection Continuity of all conductors, Earth bond, Insulation & Polarity From Rigel Medical ■ Rigel 266 Plus Manual Safety Analyser ■ Rigel 277 Plus Automatic Safety Analyser ■ Rigel 288 Electrical Medical Safety ■ Rigel BP-SiM NIBP Simulator ■ Rigel SP-SiM SP02 Simulator ■ Rigel UNI-SiM Vital Signs Simulator ■ Rigel 333 Patient Simulator ■ Rigel 344 Defibrillator Tester ■ Rigel 355 Ventilator...
Open the catalog to page 6All RIGEL Medical catalogs and technical brochures
-
SafeTest 60
3 Pages
-
CITREX H3
1 Pages
-
SafeTest 99
3 Pages
-
FlowAnalyser PRO
4 Pages
-
CITREX H5
2 Pages
-
Guide to Infusion Pump Testing
19 Pages
-
Guide to Electrosurgery
19 Pages
-
IEC 62353
29 Pages
-
IEC 60601
18 Pages
-
Global Brochure
17 Pages
-
CITREX
6 Pages
-
PRODUCT RANGE 2018
12 Pages
-
Med-eBase
2 Pages
-
PRODUCT RANGE 2017
12 Pages
-
UniPulse 400
2 Pages
-
Printers and Scanners
6 Pages
-
Rigel 62353+
5 Pages
-
VenTest 800 Series
8 Pages
-
Rigel 288+
5 Pages
-
PULS-R
2 Pages
Archived catalogs
-
PatSim200
2 Pages
-
Rigel Multi-Flo Datasheet
6 Pages
-
Uni-Pulse
6 Pages
-
M e d - e B a s e v 2 . 0
3 Pages
-
RIGEL
20 Pages
-
SP-SIM SpO2 Simulator
5 Pages
-
BP-SiM NIBP Simulator
5 Pages
-
Rigel Medical Brochure - USA
20 Pages
-
Rigel Medical Brochure UK
20 Pages