Tried. Tested. Trusted. A new hand - held, high performance pulse oximetry simulator for the fast, accurate and efficient testing of SpO2 devices. The lightweight and battery powered Rigel SP-Sim is the first hand - held simulator of its type and utilises new technology to eliminate the inconsistencies that can often be associated with testing using traditional methods like an optical finger. ■ Portable and Lightweight Ideal for field service technicians and in-situ testing of SpO2 performance Market leaders in oximeters specify specialist biomedical test equipment ■ Electronic and Optical Simulation...
Open the catalog to page 2Tried. Tested. Trusted. to collect not only the electrical safety test record but also the performance of the ■ Tough and durable labels Medical Device. The complete PPM in one ■ Resistant to most solvents used in the single record. medical sector ■ Opportunity to advertise your logo Furthermore, the software allows you to produce certificates and print or email them to make sure test records are kept for future emergency telephone number with every Applications ■ Verify the correct performance of SpO2 – pulse oximeter monitors ■ Simulation of different patient conditions through oximetry ■ Testing...
Open the catalog to page 3Tried. Tested. Trusted. simulator. Today’s industry demands test communication, asset management equipment that can save time and cost, thus facilities, user configurable Performance offering greater flexibility. These factors have all been taken into account during the We believe that the SP-Sim is set to development of the SP-Sim. The test capabilities and functionality exceed that of performance Testing. most common SpO2 Simulator yet the instrument is only a fraction of the size and weight. No other SpO2 simulator on the market Biomed testing on the move. offers a hand-held enclosure with...
Open the catalog to page 4Tried. Tested. Trusted. SPECIFICATIONS Also available Technical Specifications Simulation Optronic (Electronic & Optical), indirect via probe adaptor box probe & full chain ± 0.5% of reading between 80 - 100% SpO2 ± 1% of reading between 50 - 79% SpO2 Heart rate Datex, Datex Ohmeda, Nellcor, N.Oximax, Masimo,Criticare, Datascope, Philips (HP), CSI, Novametrix, Nihon Kohden, Nonin, From Rigel Medical ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Rigel 266 Plus Manual Safety Analyser Rigel 277 Plus Automatic Safety Analyser Rigel 288 Hand - held Safety Analyser Rigel BP - Sim NIBP Simulator Rigel 333 Patient Simulator Rigel...
Open the catalog to page 52 Pages
3 Pages
1 Page
3 Pages
4 Pages
2 Pages
19 Pages
19 Pages
29 Pages
18 Pages
17 Pages
6 Pages
12 Pages
6 Pages
5 Pages
2 Pages
8 Pages
5 Pages
2 Pages
12 Pages
2 Pages
6 Pages
20 Pages
5 Pages
3 Pages
20 Pages
20 Pages
6 Pages