1. Catalogs
  2. RIMSA
  3. Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno
video corpo

Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno

Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno
1 / 20 PagesView full catalog

Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno

Product catalog summary
Introduction
RIMSA specializes in engineering safety for medical devices, focusing on surgical lights. Their products adhere to international standards like IEC 60601-2-41 and the Medical Device Directive 93/42/CEE, ensuring reliability and compliance.

Quality Light
RIMSA prioritizes 'quality light' in surgical environments, emphasizing luminous intensity, color reproduction, shadow elimination, and color temperature. Their lamps are designed to meet these criteria for optimal performance in operating theaters.

Light Intensity
Recommended luminous intensity is 100,000-130,000 lux for surgeries and 50,000 lux for smaller procedures. Multi-elliptical and parabolic reflectors are used to provide intense, shadowless light.

Color Reproduction and Shadowless Light
The lamps achieve a high color rendering index (CRI) of 94 Ra for accurate color reproduction, with reflector designs that eliminate shadows.

Color Temperature and Cold Light
With a color temperature of 4,200 °K, the lamps mimic daylight, aiding surgical precision. Special filters remove infrared rays to keep the light 'cold' and prevent tissue dehydration.

Visible Wavelength
Halogen lamps are used for their consistent visible emission spectrum, closely resembling sunlight.

DLE Device and Laminar Flow
The DLE device ensures continuous light with a backup lamp and is compatible with laminar flow systems in operating theaters.

Product Features
  • D400 Series: Features high-tech illumination with 360° rotation, cold light, and an elliptic reflector for focused light.
  • TRIS: Provides shadowless light with three-dimensional depth, suitable for small surgeries.
  • SATURNO: Offers stable, easy-to-handle light with a parabolic reflector for small surgeries and examinations.


Conclusion
RIMSA's surgical lights are engineered for safety, reliability, and compliance with medical standards, offering high-quality illumination for various medical procedures.

Overview
The document details technical specifications and performance data for medical lighting systems, emphasizing the importance of adequate lighting in surgical environments.

Technical Specifications
Performance metrics include light intensity, color temperature, and color rendering index. Dimensions, electrical data, power consumption, and lamp life are also detailed. The systems are designed to minimize shadows and provide three-dimensional depth of light.

Performance Data
Key indicators include light intensity at 1 meter, color temperature, and light field diameter at various illuminance levels. Data on illumination depth and radiated energy to illuminance ratio is provided.

Electrical and General Data
Information on power transformers, electrical absorption, and lamp types is included. Minimum room height for installation and compliance with directives like IEC60601-2-41 and 93/42/EEC are specified.

Optional Features
Optional features include a DLE device for bulb commutation, a battery group with an automatic charger, and a TVCC camera arm.

Compliance and Standards
Products comply with medical device Class I standards and are certified under EN 9001:2000 and EN 13485:2003. The manufacturer reserves the right to improve products without notice.
See more

Catalog excerpts

Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-2

catalogo_medicale_new_2010:Layout 1 ENGINEERING 22-07-2010 8:24 Pagina 2 IN SAFETY What happens if the smallest part of your medical device isn't be reliable and consequently compromises the whole product? RIMSA engineers focused on safety to develop innovative, original and efficient surgical lights. Every mechanical and electrical components have been tested for several years before to being installed on OT lamps. Experience, reliability, and research enabled RIMSA to develop OT surgical lights, achieving prestigious and incomparable results: excellent lighting performances, cold light shadowless,...

 Open the catalog to page 2
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-3

catalogo_medicale_new_2010:Layout 1 22-07-2010 8:24 Pagina 3 LIGHT INTENSITY The threshold of intense luminosity tolerated by each individual is subjective and depends upon the predisposition of the eye to luminous display. Generally high luminous intensity provokes dazzle phenomena in the eye, stimulates the musculature of the pupil with consequent sight fatigue, and disturbs the surgeon’s vision during the rapid succession of images from the operating field to the surrounding environment. This is why we advise a luminous intensity between 100,000-130,000 lux for surgical operations, while a...

 Open the catalog to page 3
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-4

quality lig|it DEEP LIGHT The depth of light illuminates the cavity three-dimensionally, also helping to highlight the smallest details. The geometry of tens of connected ellipsoids directs the luminous rays into a cone of light, illuminating in depth. COLD LIGHT The fundamental prerogative of an excellent shadowless lamp is its "cold" light, avoiding dehydration of the tissues during the operation and rendering the surgeon's work comfortable. Special "RMS97 filters" (D400) and the "Dichroic treatment" (Saturno and Tris) eliminate the infrared rays generated by the halogen lamp, guaranteeing...

 Open the catalog to page 4
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-5

LAMINAR FLOW The two-satellite solution is particularly advised for operating theatres with laminar flow. In this case the reduced dimensions of the cupolas does not interfere with the laminar flow. ELLIPTIC REFLECTOR In aluminium, consisting of tens of conneted ellipsoids joined together. The "elliptic" form allows obtaining excellent luminous intensity with a low energy halogen lamp and the reflected light is always in focus. The elliptic reflector has a treatment "mirror" to increase reflection and a treatment "sun-light" to raise the colour temperature to 4200K with an index of chromatic...

 Open the catalog to page 5
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-6

catalogo_medicale_new_2010:Layout 1 22-07-2010 8:24 Pagina 6 D400 Illumination for operating theatre with reflected optics system ELLITTICA D400 celing The D400 series is a high technology apparatus designed to guarantee technical-illumination performance, unique of its kind. The reduced dimensions and the lightness of the reflector give the product stability and make it extremely easy to handle. The luminous beam is always in focus, starting from a minimum distance of 60 cm. The diameter of the field illuminated is regulated manually by rotating the handle, which can be sterilised, at the centre...

 Open the catalog to page 6
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-7

ROTATION WITHOUT The central and lateral rotations are Transmission of current takes place through sliding contacts produced in The "elliptic" reflector reflects the luminous rays generated by the bulb over the operating field in dotted form to guarantee constant focus and three- dimensional light. Thanks to this principle the light is always in focus starting from a distance of 60 cm from Special "RMS97" filters eliminate the infrared rays generated by the halogen lamp, avoiding dehydration of the tissues during the operation and rendering the surgeon's work In aluminium, consisting of tens...

 Open the catalog to page 7
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-8

catalogo_medicale_new_2010:Layout 1 22-07-2010 D400 8:24 Pagina 8 D400 for wall STRUCTURE IN ALUMINIUM The load-bearing “light-struct” structure of the lamp is in aluminium tubing with a diameter of 45 mm. This detail facilitates installation without the aid of mechanical lifts, making the product suitable for any type of ceiling and easy to manoeuvre, facilitating the dispersion of heat. ADJUSTOR LUMINOSITY The luminous intensity is adjusted electronically by 20,000 lux at maximum intensity. The surgeon can set the luminous intensity desired in relation to the type of operation. 7

 Open the catalog to page 8
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-9

catalogo_medicale_new_2010:Layout 1 22-07-2010 8:24 Pagina 9 DEVICE DLE On request it is possible to fit the DLE device, consisting of an electronic commutation card and reserve lamp. In case of damage to the main lamp, the electronic card instantaneously commutes the switching of the reserve lamp on and an intermittent green telltale led switches on to signal the damage and request the substitution of the burnt-out lamp. ROTATION AT 10° The floor lamp version has been designed to be rotated 10° on the vertical stand without needing to rotate the base. This technical solution makes it particularly...

 Open the catalog to page 9
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-10

operating theatre/With ¡ reflected optics^ystem RIMSA shadowless lamps satisfy the requisites of "quality light'' The D600 series is a high technology apparatus designed to guarantee technical- illumination performance, unique of its kind. Complex mathematical calculations have allowed the creation of the original and revolutionary stratified and in-depth multi- elliptical reflector for intense light without shadows. The reduced dimensions and the lightness of the reflector give the product stability and make it extremely easy to handle. Special RMS97 filters eliminate the infrared rays generated...

 Open the catalog to page 10
Brochure Major and Minor Operating Lights Halogen D/ Serie, TRIS and Saturno-11

Special "RMS97" filters eliminate the infrared rays generated by the halogen lamp, avoiding dehydration of the tissues during surgeon's work comfortable. The "elliptic" reflector reflects the luminous rays generated by the bulb over the operating field in dotted form to guarantee constant focus and three-dimensional light. Thanks to this principle the light is always in focus starting from a particularly advised for operating theatres with laminar flow. In this case the reduced dimensions of the cupolas does not interfere with the laminar flow. The luminous intensity is adjusted maximum intensity.The...

 Open the catalog to page 11

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.