video corpo

Brochure Pentaled 63N_N-Series
16Pages

{{requestButtons}}

Catalog excerpts

Brochure Pentaled 63N_N-Series - 1

PENTALED The first one, the original one!

Open the catalog to page 1
Brochure Pentaled 63N_N-Series - 3

Right from its earliest days, RIMSA has always had a clear goal: to satisfy surgeons’ needs. RIMSA is fully aware that the key to meeting this goal is INNOVATION. Cutting-edge solutions designed by our engineers combine revolutionary new technology with consolidated concepts, such as “WHITE LIGHT” and “INDIRECT LIGHT”, as used in the RIMSA Pentaled series. Designers of the world’s first scialytic lamp using LED technology (patented in September 2002), RIMSA now applies the experience it has gained over the years to its new PENTALED N-Series. N-Series (Pentaled63N, Pentaled30N) is a highly...

Open the catalog to page 3
Brochure Pentaled 63N_N-Series - 4

PENTALED N-Series

Open the catalog to page 4
Brochure Pentaled 63N_N-Series - 5

The use of indirect light makes for: - 3D illumination of the operating field - no shadows - no risk of dazzling The indirect light provided by all Pentaled lamps guarantees cold light, depth and no stress or dazzling for the surgeon. This is due to especially calculated parabolic dishes that reflect the entire spectrum of light emitted by each LED lamp in a punctiform manner, without dispersion. This means: • fewer LEDs are needed, • lower irradiated heat in the operating field. Thanks to the physical principle of indirect light, the surgeon and his/her assistants are never disturbed by...

Open the catalog to page 5
Brochure Pentaled 63N_N-Series - 6

Professionalism and quality distinguish all RIMSA products White light Nature has always inspired man’s every discovery! The sun is the light source par excellence and its rays emit monochromatic light, i.e. identical colour. Using this as a starting point, RIMSA has designed lamps that use only “white light” LEDs to avoid the risk of surgeons perceiving variations in the colour temperature (°K) within the operating field and to prevent unnecessary coloured shadows. Indirect light The use of indirect light makes for: - 3D illumination of the operating field - no shadows - no risk of...

Open the catalog to page 6
Brochure Pentaled 63N_N-Series - 7

Cold light Any increase in thermal irradiation in the operating field is proportional to the number and power of the LEDs used. RIMSA uses a reduced number of LEDs thanks to the concept of “Indirect Light”. 5000°K – 4500°K By simply pressing the digital key “K” on the membrane keyboard, the surgeon can choose between two different “white light” temperatures – 5000°K and 4500°K – without altering the light intensity. E-glass The light source is protected by “E-Glass”, a light diffusing screen made from clear tempered glass and coated with a special high strength film to avoid shards falling...

Open the catalog to page 7
Brochure Pentaled 63N_N-Series - 8

PENTALED63N is a hi-tech product designed to guarantee excellent performance levels PENTALED63N has 72 elliptical reflectors split into 8 modules, each containing 9 LEDs. The modules are mechanically focused rotating the sterilizable handle. The multiplicity of the luminous sources and the elliptical geometry of the parabolas studied to reflect in the depth the light beams generated by the Leds, grant scialytic light for a threedimensional illumination without shadows. PENTALED63N does not dazzle: thanks to the principle of indirect light, the lamp oriented towards different positions does...

Open the catalog to page 8
Brochure Pentaled 63N_N-Series - 9

Available versions:

Open the catalog to page 9
Brochure Pentaled 63N_N-Series - 10

PENTALED30N: high performances in reduced dimensions PENTALED30N is especially recommended for operating theatres where the surgeon needs a small lamp to avoid interference with other overhead equipment. Excellent for oral and maxillofacial surgery and aesthetic plastic surgery. It has 30 elliptical reflectors split into 6 modules, each containing 5 LEDs, providing 130,000 Lux. An aluminium ring runs around the dome for easier positioning. A central sterilizable handle facilitate positioning of the lamp. Focalization and light field diameter can be easily adjusted moving the central handle...

Open the catalog to page 10
Brochure Pentaled 63N_N-Series - 11

Available versions:

Open the catalog to page 11
Brochure Pentaled 63N_N-Series - 12

Optional solutions Integrated solutions for the surgery of the future By operating with the most prestigious international hospital complexes, RIMSA has acquired extensive know-how in the surgical field, designing innovative solutions aimed at satisfying customer demands. That is why we are also able to offer optional solutions such as: monitor holding arms, TV shooting systems with TVCC HD and SD, remote-control interfaces both by means of cable and IR (infra-red) remote control and UPS units. We also devise personalised solutions for installing our lamps in operating theatres and mobile...

Open the catalog to page 12
Brochure Pentaled 63N_N-Series - 13

Light intensity at 1m distance (Ec) Color temperature: double selection Color rendering index (CRI) Diameter and focus adjustment Light field diameter adjustable from – to – (cm) d10 light field diameter where illuminance reaches 10% of Ec (small ø) d10 light field diameter where illuminance reaches 10% of Ec (big ø) d50 light field diameter where illuminance reaches 50% of Ec (small ø) d50 light field diameter where illuminance reaches 50% of Ec (big ø) Total radiated energy Ee where the illuminance reaches max level (W/m2) Ratio between radiated energy Ee and illuminance Ec (mW/m2.lx)...

Open the catalog to page 13
Brochure Pentaled 63N_N-Series - 16

E-mail: info@rimsa.it Rimsa retain a right to improve the products in the catalogue without notice. Reproduction in part or in whole is forbidden. RESEARCH & COMPONENTS

Open the catalog to page 16

All RIMSA catalogs and technical brochures

  1. Saturno-led

    1 Pages

  2. Tris-led

    1 Pages

  3. U29

    4 Pages

  4. Observa

    12 Pages

  5. D-series

    20 Pages

  6. PRIMALED

    12 Pages

  7. PENTALED 63

    20 Pages

  8. PENTALED 12

    16 Pages