Catalog excerpts
The first one,the original one!
Open the catalog to page 1Right from its earliest days, RIMSA has always had a clear goal: to satisfy surgeons’ needs. RIMSA is fully aware that the key to meeting this goal is INNOVATION. Cutting-edge solutions designed by our engineers combine revolutionary new technology with consolidated concepts, such as WHITE LIGHT and INDIRECT LIGHT, as used in the RIMSA Pentaled series. Designers of the world’s first scialytic lamp using LED technology (patented in September 2002), RIMSA now applies the experience it has gained over the years to its new PENTALED E-Series. E-Series (Pentaled81, Pentaled105 and Pentaled30E) is...
Open the catalog to page 2Light has a crucial affect on man's ability to work. Proper lighting makes working conditions, reduces stress levels, The most important factor when considering artificial light is the colour rendering index that measures the capacity of a light source to reproduce the true colours or more is normally held that the light source has good colour rendering properties. This value has (International Commission minimum requirement relevant International from the average of eight given that the human eye Human eye sensitivity curve The spectrum of electromagnetic radiation visible to the human eye...
Open the catalog to page 3RI&SAF DE RIM S A PEIRTaLEO 81 RI/ftSAFE White light Nature has always inspired man's every discovery! The excellence and its rays emit identical colour. Using this as a starting point, RIMSA has designed lamps that use only white light LEDs to avoid the risk of surgeons within the operating field coloured shadows. Indirect light operating field lens that lets the surgeon illuminated operating field electronically, without The indirect light provided Py all Pentaled lamps guarantees cold light, depth and no stress or dazzling for the surgeon. This is due to especially calculated paraPolic...
Open the catalog to page 4Professionalism and quality distinguish all RIMSA products: the result of more than seventy years’ experience in the field. Cold light Any increase in thermal irradiation in the operating field is proportional to the number and power of the LEDs used. RIMSA uses a reduced number of LEDs thanks to the concept of Indirect Light. 5000°K – 4500°K By simply pressing the digital key K on the membrane keyboard, the surgeon can choose between two different white light temperatures – 5000°K and 4500°K – without altering the light intensity. E-Deep (deep light) The centre of the lamp is fitted with...
Open the catalog to page 5PENTALED81 is a hi-tech product designed to guarantee excellent performance levels. 81 elliptical reflectors split into 9 modules, each containing 9 LEDs. The lamp lens is designed to guarantee perfectly focused lighting, i.e. without the need to focus the light every time the dome is moved. The light is pre-focused at different distances (from 80 cm to 200 cm). The E-View system lets the surgeon adjust the extent of the lit field to get the right type of light for each surgical procedure. The light structure of the lamp makes it easy to handle and yet still very stable. The controls on the...
Open the catalog to page 6PENTALED105 is the top of the range product. It has a central module like the PENTALED81 lamp and 4 side petals, each fitted with 6 LEDs radiating outwards. This configuration offers two great advantages: • Increased scialytic effect • Increased depth of field thanks to the double focalisation E-Focus The central and side modules are designed to provide lighting at two different focal distances and thus guarantee greater depth of light and constant light intensity without losing focus. The E-Deep module is fitted at the centre of the lamp: this has 9 LEDs with special parabolic dishes...
Open the catalog to page 7PENTALED30E: compact size, great performances PENTALED30E is especially recommended for operating theatres where the surgeon needs a small lamp to avoid interference with other overhead equipment. Excellent for oral and maxillofacial surgery and aesthetic plastic surgery. It has 30 elliptical reflectors split into 6 modules, each containing 5 LEDs, providing 130,000 Lux. An aluminium ring runs around the dome for easier positioning. The E-View system lets the surgeon adjust the extent of the lit field to get the right type of light for each surgical procedure.
Open the catalog to page 8Optional solutions Color temperature: double selection Color rendering index (CRI) Light field diameter adjustable from – to – (cm) Diameter adjustment d10 light field diameter where illuminance reaches 10% of Ec d50 light field diameter where illuminance reaches 50% of Ec Total radiated energy Ee where the illuminance reaches max level (W/m ) 392 Ratio between radiated energy Ee and illuminance Ec (mW/m2lx) Radiated UV energy with wavelength less than 400nm (W/m2) EndoLED light intensity min-max Primary alternating voltage (V a.c.) Secondary continue voltage (V d.c.) Classification of...
Open the catalog to page 9RlMSA ) ^-SERIES E-mail: info@rimsa.it Rimsa retain a right to improve the products in the catalogue without notice. Reproduction in part or in whole is forbidden. RESEARCH & COMPONENTS
Open the catalog to page 11All RIMSA catalogs and technical brochures
-
OBSERVA SERIES
2 Pages
-
PENTALED 28 / 12
2 Pages
-
Saturno-led
1 Pages
-
Tris-led
1 Pages
-
PENTALED N- SERIES
2 Pages
-
UNICA 860 / 520
2 Pages
-
U29
4 Pages
-
2019 GENERAL CATALOGUE
23 Pages
-
UNICA520 Brochure
16 Pages
-
Observa
12 Pages
-
Brochure Tris-led Saturno-led
12 Pages
-
Brochure Pentaled 63N_N-Series
16 Pages
-
Technical data Pentaled 12
1 Pages
-
D-series
20 Pages
-
PRIMALED
12 Pages
-
PENTALED E-SERIE
20 Pages
-
Brochure Examination Lamps
6 Pages
-
PENTALED 30 & PENTALED 9 FF
12 Pages
-
PENTALED 63
20 Pages
-
PENTALED 12
16 Pages
Archived catalogs
-
General Catalogue
16 Pages