GENERAL CATALOGUE - 2

IR (Remote Control) Wall Control Panel a Battery Group

Open the catalog to page 2
GENERAL CATALOGUE - 3

1943 Palmino Longoni is welcomed to the Italian Inventors Guild INNOVATION RIMSA, established by Palmino Longoni in 1936, was initially a mechanical workshop dedicated to repairing typewriters and the like (Riparazione di Macchine da Scrivere e Affini); hence the acronym RI.M.S.A. The transition from repair workshop to production facility took place in the 1940s, when Mr. Palmino Longoni decided to give shape to a product of his own. Since then, RIMSA has focused on the design and development of pantograph lamps. Company growth resulted in an expansion of the product range with the...

Open the catalog to page 3
GENERAL CATALOGUE - 4

DETERMINATION AND PASSION, THE ART OF INNOVATING. RIMSA is a “long-standing” but not an old company. Backed by its history, traditions and pride, RIMSA has always put “Uniqueness” at the centre of its organization, based on the promotion of human resources, technological updating, “simple” management, and product quality. All these elements together lead to the achievement of the corporate “purpose” identified as follows: continuity and development of the Company, professional growth and staff development, research and innovation, and acquisition of ne

Open the catalog to page 4
GENERAL CATALOGUE - 5

MAIN FEATURES LIGHT EMITTING SURFACE The surgical light main feature is the removal of shadows on the operating field; hence the surgical effect is defined as the ability of a lighting source to prevent any shadows in the illuminated area despite the obstacles that are present between the lighting source and the illuminated field. Over the years and thanks to different lighting technology, several methods of doing so have been deployed. Nevertheless, the most efficient way to obtain a reliable surgical effect is that of illuminating the surgical field by several different lighting rays...

Open the catalog to page 5
GENERAL CATALOGUE - 6

2R DOUBLE REFLECTION In 2017, Rimsa patented the 2R, double reflection technology which ensures the maximization of the lighting emitting surface thus allowing UNICA Series products to achieve a terrific surgical effect and offering a completely glare free illumination. GLARING EFFECT A surgical light offers up to 160.000 lux. The literature suggests that such a high illuminance constitutes a major risk in the operating room. The surgeon, its equipe and all those persons working in close proximity with such an intense light are subject to the glaring risk. Rimsa drastically reduced the...

Open the catalog to page 6
GENERAL CATALOGUE - 7

UNICA 860 / 520 YOUR BEST ALLY IN THE OPERATING ROOM. With the models of the Unica series, Rimsa has obtained the complete elimination of the glare effect. Thanks to 2R technology - double reflection it is possible to obtain a complete suppression of shadows, the maximization of the light emitting surface and an absolute glare free light.

Open the catalog to page 7
GENERAL CATALOGUE - 8

860 520 Light intensity at 1 m distance (Ec) Light head diameter Color temperature Color rendering index (CRI) Diameter adjustment d10 light field diameter where illuminance reached 10% of Ec Light field diameter adjustable from-to Depth of illumination IEC 60601-2-41 (L1+L2) at 60% Depth of illumination IEC 60601-2-41 (L1+L2) at 20% Total radiated energy Ee where the illuminance reaches max level Ratio between radiated energy Ee and illuminance Ec Average led life Control of the illuminance Electrical absorption Electronic Electronic Directive 93/42/EEC (main directive and further...

Open the catalog to page 8
GENERAL CATALOGUE - 9

U 29 A COMFORTABLY AFFORDABLE SURGICAL LIGHT U29 combines the indirect technology consolidated by the success obtained by the Pentaled Series with the elegant and compact design of Unica. U29 is a high-performance lamp, strongly engineered and comfortably affordable, so that any surgeon can benefit from it.

Open the catalog to page 9
GENERAL CATALOGUE - 10

Performances Light intensity at 1 m distance (Ec) Light head diameter Color temperature Color rendering index (CRI) Diameter adjustment d10 light field diameter where illuminance reached 10% of Ec Light field diameter adjustable from-to Depth of illumination IEC 60601-2-41 (L1+L2) at 60% Depth of illumination IEC 60601-2-41 (L1+L2) at 20% Total radiated energy Ee where the illuminance reaches max level Ratio between radiated energy Ee and illuminance Average led life Control of the illuminance Electrical absorption Directive 93/42/EEC (main directive and further amendments) - Norm IEC...

Open the catalog to page 10
GENERAL CATALOGUE - 11

PENTALED E - SERIES ELECTRONIC DIAMETER ADJUSTMENT The electronic adjustment allows the operator to easily swap between 2 diameter sizes from the keyboard without modifying the light intensity at the center.

Open the catalog to page 11
GENERAL CATALOGUE - 12

Performances 81 30 E Light intensity at 1 m distance (Ec) Light head diameter Color temperature Color rendering index (CRI) Diameter adjustment d10 light field diameter where illuminance reached 10% of Ec Light field diameter adjustable from-to Depth of illumination IEC 60601-2-41 (L1+L2) at 60% Depth of illumination IEC 60601-2-41 (L1+L2) at 20% Total radiated energy Ee where the illuminance reaches max level Ratio between radiated energy Ee and illuminance Ec Average led life Control of the illuminance Electrical absorption Directive 93/42/EEC (main directive and further amendments) -...

Open the catalog to page 12
GENERAL CATALOGUE - 13

PENTALED N- SERIES MANUAL DIAMETER ADJUSTMENT The Pentaled N-series made a breakthrough in medical lighting. It has been the first LED surgical light ever displayed to the public. The manual focalization inside the sterile area grants a precise and immediate control of the light field. The Focus function is activated by the surgeon rotating the sterile central handle.

Open the catalog to page 13
GENERAL CATALOGUE - 14

Performances 63 N Light intensity at 1 m distance (Ec) Light head diameter Color temperature Color rendering index (CRI) Diameter adjustment d10 light field diameter where illuminance reached 10% of Ec Light field diameter adjustable from-to Depth of illumination IEC 60601-2-41 (L1+L2) at 60% Depth of illumination IEC 60601-2-41 (L1+L2) at 20% Total radiated energy Ee where the illuminance reaches max level Ratio between radiated energy Ee and illuminance Ec Average led life Control of the illuminance Electrical absorption Directive 93/42/EEC (main directive and further amendments) - Norm...

Open the catalog to page 14

All RIMSA catalogs and technical brochures

  1. Saturno-led

    1 Pages

  2. Tris-led

    1 Pages

  3. U29

    4 Pages

  4. Observa

    12 Pages

  5. D-series

    20 Pages

  6. PRIMALED

    12 Pages

  7. PENTALED 63

    20 Pages

  8. PENTALED 12

    16 Pages