

Catalog excerpts

LA MP IN TH EW OR LD brightening ideas D TH E FI RS T M ED IC AL LE D THE ORIGINAL E AL T EN P
Open the catalog to page 1
LI G Y UA LIT RIMS AQ T H A quality light helps doctors and surgeons in the operating theatre, this is related to the need to guarantee the reliability of the visual information perceived by the surgeons. This is why Rimsa has always developed new products, paying great attention to the technological avant-garde. RIMSA has been the first company in the world to design the LED scialytic lamp (patent registered). Now, as then, Rimsa engineers are constantly searching for innovative solutions to improve the product performance and it is thanks to the experience gained over time that Rimsa is...
Open the catalog to page 2
WHITE LIGHT The nature has always inspired every man discovery. The sun is the preeminently source of light; its rays have a monochromatic light emission. It means that every ray has got an identical chromaticity. According to this consideration, RIMSA has adopted the principle of emission of monochromatic light, to avoid any change of temperature of colour (°K) and colour shade on the operating field. In that case the interposition of the surgeon head or hands between the lamp and the patient doesn’t interfere at all on the quality and above all on the colour temperature of the light on...
Open the catalog to page 4
12 EXCELLENT REASONS TO CHOOSE PENTALED 12: JUST TWELVE LEDS FOR MORE THAN 50.000 LUX. THE PARABOLA OPTIMIZES THE LIGHT FLOW OF THE LEDS INCREASING THE EFFICIENCY. “INDIRECT” LIGHT – Indirect light means reflected light. On the basis of the physical principle of reflection the rays of light emitted by the LED are reflected by an ellipse punctiformly on the operating field. 2 WHITE LIGHT – to prevent the light from resolving into several colors in the lit area. 3 COLD LIGHT – lower number of LEDs, lower temperature generated for the doctor and patient's comfort. 4 LONGEVITY: the low power...
Open the catalog to page 5
The many undisputed advantages of Led technology are the reason for its fast development in all sectors, including the medical one. Now, as 8 years ago, Rimsa was ahead of its time designing a Led lamp for PENTALED12, 5.000K bright and cold light reproduces colours faithfully, assuring an excellent definition of details, a very important INDIRECT LIGHT The physical principle of reflection is the base of Rimsa lamps and is applied through a system of ellipses. They reflect the light rays obtaining a high light intensity with a reduced number of Leds: over 1 metre with just 12 Leds....
Open the catalog to page 6
STERILIZABLE HANDLE Movements are possible thanks to the sterilizable handle. The ergonomic design guarantees a high handling and the versions available allow use in any surgery or laboratory. ADJUSTABLE LIGHT INTENSITY The lower part of the reflector incorporates, besides the switch, a digital control to adjust the light with visual signal of the intensity set. 52.000 50.000 45.000 Light Intensity [lux] 40.000 35.000 30.000 30 000 25.000 20.000 15.000 10.000 5.000 ‐25 ‐20 ‐15 ‐10 ‐5 0 0 5 Diameter [cm] 10 15 20 25 VERSATILE “PENTALED12” characteristics make it a unique lamp. The light...
Open the catalog to page 7
PENTALED 12 MOBILE VERSION The main feature of the mobile version Pentaled 12 is the great ease with which it can be positioned. The base is mounted on castors so that the lamp can be easily moved to various surgeries. The anti-static castors are equipped with brakes to ensure maximum stability.
Open the catalog to page 8
PENTALED 12 CEILING VERSION The ceiling-mounted version of the Pentaled 12 is suitable for operating theatres and surgeries of reduced dimensions or when the mobile version would be an obstacle in the presence of drip stands or medical-equipment trolleys. -9-
Open the catalog to page 9
PENTALED 12+12 The Pentaled 12+12 model is recommended for micro-surgery operations carried out by a team which might cause more shadows in the operating area.
Open the catalog to page 10
PENTALED 12 WALL VERSION The wall-mounted version of the Pentaled 12 is a valid alternative to the mobile and ceiling-mounted versions, and is recommended for operating theatres and surgeries of reduced dimensions where space saving is required. The lamp can be folded back against the wall when not in use. The wall-mounted version is also recommended when one lamp needs to be shared between two beds (for example, in emergency rooms, recovery rooms, reanimation). - 11 -
Open the catalog to page 11
Technical Data PERFORMANCES light intensity at 1 m distance (Ec) Lux 50.000 Colour Rendering Index (CRI) Ra 90 Colour Temperature Light field diameter where the illuminance reaches 50% of Ec (d50) Light field diameter where the illuminance reaches 10% of Ec (d10) Dept of illumination IEC 60601-2-41- (L1+L2) at 20% of Ec Total radiated energy Ee where illuminance reaches max level Ratio between radiated energy Ee, and illuminance Ec Radiated UV energy whit wavelight less than 400 nm ELECTRICAL DATA °K 5.000 mm 85 mm 140 cm W/m2 mW/m2.lx W/m 2 150 (30÷180) 119 2,38 0,001 Power transformer...
Open the catalog to page 12
PENTALED 12 PENTALED 12 CEILING MOBILE PENTALED PENTALED 12 12+12 WALL - 13 -
Open the catalog to page 13
RIMSA AND THE ENVIRONMENT The respect and the protection of the environment have always been a priority to RIMSA. RIMSA has promoted renewable non-polluting energy sources, equipping each plant with photovoltaic systems which produce 100% requirements for constructing its devices. This renewable energy, obtained from the sun without emissions of CO2 in the environment, contributes towards the reduction of air pollution. RIMSA: “The photo shows the first RIMSA plant equipe with photovoltaic panels”. RIMSA follows a thorough ecological policy for its products as well: - it has been the first...
Open the catalog to page 15
March 2010 RIMSA retain a right to improve the products in the catalogue without notice. Reproduction in part or in whole is forbidden. Via Monterosa, 18/22 - 20038 Seregno (MB) - Italy - Tel. + 39 0362 325709 - Fax + 39 0362 328559 E-mail: info@rimsa.it - www.rimsa.it EN 9001:2000 EN 13485:2003
Open the catalog to page 16All RIMSA catalogs and technical brochures
-
OBSERVA SERIES
2 Pages
-
PENTALED 28 / 12
2 Pages
-
Saturno-led
1 Pages
-
Tris-led
1 Pages
-
PENTALED N- SERIES
2 Pages
-
UNICA 860 / 520
2 Pages
-
U29
4 Pages
-
2019 GENERAL CATALOGUE
23 Pages
-
UNICA520 Brochure
16 Pages
-
Observa
12 Pages
-
Brochure Tris-led Saturno-led
12 Pages
-
Brochure Pentaled 63N_N-Series
16 Pages
-
Brochure Pentaled E-Series
11 Pages
-
Technical data Pentaled 12
1 Pages
-
D-series
20 Pages
-
PRIMALED
12 Pages
-
PENTALED E-SERIE
20 Pages
-
Brochure Examination Lamps
6 Pages
-
PENTALED 30 & PENTALED 9 FF
12 Pages
-
PENTALED 63
20 Pages
Archived catalogs
-
General Catalogue
16 Pages