
Catalog excerpts

AVENIO Edge System Technical specifications General Configuration Floor model 1–48 samples for library prep and target enrichment Up to 31 hrs (including 16 hrs hybridization time) Setup time Approximately 15 mins prior to run Inventory check Pre-run consumable list. Pre-run check for empty positions and incorrectly placed items Quality control on deck Fluorescence-based quantification method 2D imager scans for 2D and 1D barcodes Regulatory label US-IVD, CE-IVD Kits and applications Reagent design Pre-filled, barcoded, ready-to-use. Reagent kits are optimized for 3 runs. Sample type Hybridization-based target enrichment Software and connectivity Traceability 21 CFR part 11 (subsection B), audit trail, process monitoring, user guidance Data export CSV, XML and PDF run exports. Sample input in .csv format 2 external USB ports and 1 network port AVENIO Connect Workflow Manager or HL7 LIS connection, Roche remote service solution Deck capacity Consumables 17 tip racks of 96 tips each, supporting 3 tip types (50 / 200 / 1000 μL) 6 processing plates 5 processing lids 2 quantification plates 2 tip parks 4 panel tubes (to reconstitute custom panels) 15 control mini racks; each rack includes 4 individual 2.0 ml tubes 10 troughs 20 cooled reagent tubes, 0.5 or 2.0 mL 2 primer plates 1 MagNA Pure 96 output plate or 12 MagNA Pure 24 8-tube strips, low or high profile, or 1 processing plate
Open the catalog to page 1
AVENIO Edge System Technical specifications Hardware Instrument footprint (WxDxH) Operating space (WxDxH) Construction and service space (WxDxH) Contamination control Work deck layout optimized to minimize contamination risk, UV light, optimized pipetting parameters with each TDF Pipetting head Single 8-channel pipetting head Cooling block On-deck thermocycler Temperature range thermal block: +4°C to +99°C Temperature range heated lid: +30°C to +115°C Maximum average heating rate: 4.4°C /sec Maximum average cooling rate: 2.2°C /sec Temperature accuracy: ±0.3°C at 55°C Temperature...
Open the catalog to page 2
Signature Page for MC--05897 v3.0 Aprobación normativa Jessica Betts Regulatory 11-Mar-2022 16:25:00 GMT+0000 Signature Page for MC--05897 v3.0
Open the catalog to page 3All Roche Sequencing Solutions catalogs and technical brochures
-
AVENIO NGS Oncology Assays
8 Pages
-
AVENIO Edge System
12 Pages
-
MagNA Pure 96 System
7 Pages
Archived catalogs
-
KAPA PROBE FORCE
4 Pages
-
KAPA Taq PCR Kits
2 Pages
-
MagNA Pure 96 Brochure
12 Pages
-
MagNA Pure 24 Flyer
1 Pages