1. Catalogs
  2. ROTAREX MEDITEC
  3. MEDICAL CYLINDER VALVES
video corpo

MEDICAL CYLINDER VALVES

MEDICAL CYLINDER VALVES
1 / 32 PagesView full catalog

MEDICAL CYLINDER VALVES

Product catalog summary
Introduction
Ceodeux Meditec specializes in the design and operation of medical gas equipment, prioritizing patient therapy and safety. Their products ensure adequate medical gas capacity, specific gas identity, and high-quality supply, adhering to stringent quality systems that surpass ISO 13485 standards.
Main Medical Gases
The document identifies primary medical gases such as Oxygen (O2), Air, Nitrous Oxide (N2O), Carbon Dioxide (CO2), Surgical Air, and Nitrogen (N2), detailing their applications and sources.
Product Range Overview
The product range includes valves with integrated pressure regulators, cylinder valves with residual pressure valves, standard cylinder valves, and special nitric oxide cylinder valves, each designed to meet specific medical gas requirements and standards.
Technology Overview
Ceodeux Meditec employs four main technologies: VIPR (Valve with Integrated Pressure Regulator), Residual Pressure Valve, Standard Cylinder Valve, and Pin Index Valve, ensuring safety, reliability, and ease of use.
Detailed Functionalities
The document details functionalities of integrated valves, including regulator safety relief devices, flowmeter and hose barb, pressure regulator, and residual pressure valve, enhancing safety, precision, and longevity.
How to Select Valves
Guidance is provided on selecting valves based on body materials, inlet and outlet pressures, and connection types, emphasizing the importance of choosing the right specifications to meet application needs.
Specifications
Valves integrate multiple functions such as active pressure measurement, high-pressure shut-off, filling port with check valve, residual pressure valve, pressure regulator, safety relief device, and flow selector, available in various configurations to meet diverse requirements.
Regulatory Compliance
The valves are certified according to medical and safety standards like MDD 93/42/EEC, TPED Directive 2010/35/EU, EN ISO 10524-3, and CGA E-18, approved by major medical authorities worldwide.
Key Advantages
Valves offer high performance with proven reliability, pressure and flow stability, and accuracy. Safety features include no high-pressure manipulation, preset pressure relief devices, and continuous flow settings, ensuring easy access and intuitive operation.
Technical Parameters
Key parameters for selecting the right valve include working pressure, outlet pressure, gas type, material, inlet and outlet connections, temperature range, and specific application requirements.
Product Configurations
Models such as M706, M713, and M741 offer different inlet connections, working pressures, and flow ranges, with options like protection guards, filters, and anti-dust tubes.
Emergency Back Pack
The M800 emergency backpack includes a 2L oxygen cylinder with an integrated valve, nasal cannulas, and a reinforced, waterproof bag for mobile oxygen therapy.
Standard RPV Valves
Models like M510, M540, and M978 feature low operating torque, MRI compatibility, and long service life, designed according to EN ISO standards with options like filters and burst disc safety devices.
Conclusion
Ceodeux Meditec valves provide comprehensive solutions for medical gas management, ensuring safety, reliability, and compliance with international standards.
Specifications
  • Working pressure: 232 bar
  • Temperature range: -25°C to +70°C
  • Helium leak rate at pmax: 10-3 mbar l/sec
  • Seat orifice size varies by model
  • Magnetic compatibility: Yes
  • Materials: Handwheel - polyamide, Seat - polyamide, O-ring - EPDM, Body - Chrome plated brass
Key Features
  • Low operating torque
  • MRI compatible
  • Safe, long, trouble-free life under all service conditions
  • Approved valve design
  • Tested according to ISO 10297 and CGA U9 Standard
Options
  • Various inlet options
  • Filter and burst disc safety device available
  • Thread for dip tube connection
  • Chrome plating
  • High pressure brass cylinder valve for medical oxygen
Product Series Features
  • Gas safety for O2, CO2, and various gases
  • Compatible with Ceodeux Meditec regulators
Product Configurator
  • Gas inlet connection and working pressure options for different gases
Additional Specifications for Other Models
  • Working pressure and temperature range vary by model
  • Helium leak rate and seat orifice size differ among models
  • Materials used include stainless steel, Viton®, and PCTFE
Key Features of Other Models
  • Freedom from seizure with corrosive gases
  • Positive and effective operation with low closing torque
  • Long life with replaceable valve spindle and seat
  • Low internal volume beneficial for high purity gases
Company Overview
  • ROTAREX provides gas control solutions for various industries including medical, industrial, and automotive
  • Over 90 years of experience in designing and manufacturing high-performance valves and regulators
Contact Information
  • Worldwide headquarters in Luxembourg with regional offices in North America, South America, Europe, Asia-Pacific, and the Middle East
See more

Catalog excerpts

MEDICAL CYLINDER VALVES-1

MEDICAL CYLINDER VALVES

 Open the catalog to page 1
MEDICAL CYLINDER VALVES-3

TABLE OF CONTENTS INTRODUCTION -- Ceodeux meditec solutions -- Quality first... -- The main medical gases -- Product range overview -- Technology overview -- How to select valves VALVES INTEGRATED WITH PRESSURE REGULATOR -- M706/M713 | LIFE+ -- M741 | LIFE-s -- M800 – Emergency Back Pack -- Protective Guard CYLINDER VALVE WITH RESIDUAL PRESSURE VALVE P.020 -- M510/M515/M501/M506/M520/M525 Standard RPV Cylinder Valve P.020 -- M540/M545/M530/M535 | Standard RPV off line P.021 -- M511/M516/M508/M521/M526 | Standard RPV in line P.022 -- M978/M979/C878 | Standard RPV in line P.023 -- M100/M105/M040/M045/M200/M205...

 Open the catalog to page 3
MEDICAL CYLINDER VALVES-4

Patient therapy and safety is our main focus in the design, installation, commissioning and operation of medical gas equipment QUANTITY OF SUPPLY Valves are designed in such a way sufficient medical gas capacity can be ensured in order to provide the required flows of gases for the intended number of patients to be treated at any time. IDENTITY OF SUPPLY All our products are designed, produced and controlled for a specific medical gas. All points to which the user or technical staff can connect are gas specified. There is no risk of misconnection. QUALITY OF SUPPLY Our valves maintain quality...

 Open the catalog to page 4
MEDICAL CYLINDER VALVES-5

THE MAIN MEDICAL GASES Application Source Type

 Open the catalog to page 5
MEDICAL CYLINDER VALVES-6

PRODUCT RANGE OVERVIEW Gas type Material Inlet pressure Gas type Material Inlet pressure M800 EMERGENCY OXYGEN BACK PACK p 18 M706/M713 PROTECTIVE GUARD p 19 STANDARD CYLINDER VALVE WITH RESIDUAL PRESSURE VALVE OFF LINE Gas type Material Inlet pressure Various gases Chrome plated brass 200 bar/2900 psi Various gases Chrome plated brass 300 bar/4350 psi STANDARD CYLINDER VALVE WITH RESIDUAL PRESSURE VALVE IN LINE Inlet pressure Chrome plated brass Chrome plated brass 200 bar/2900 psi Chrome plated brass 200 bar/2900 psi Chrome plated brass 200 bar/2900 psi Chrome plated brass 200 bar/2900...

 Open the catalog to page 6
MEDICAL CYLINDER VALVES-7

PRODUCT RANGE OVERVIEWSTANDARD CYLINDER VALVE M100/M105 P 24 Gas type Material Inlet pressure O, Chrome plated brass 200 bar / 2900 psi Various gases Chrome plated brass 200 bar / 2900 psi Chrome plated brass 200 bar/2900 psi Various gases Chrome plated brass 200 bar/2900 psi Material Stainless steel M966 PIN INDEX CYLINDER VALVE p 28 PIN INDEX RPV CYLINDER VALVE Gas type Material Inlet pressure o, Chrome plated or natural brass ALL RIGHTS OF CHANGE RESERVED

 Open the catalog to page 7
MEDICAL CYLINDER VALVES-8

TECHNOLOGY OVERVIEW Ceodeux Meditec uses 4 main technologies to achieve a proper and reliable gas use from the cylinder: VIPR -- Valve with integrated pressure regulator Design to save your time: Easy and Ready to use medical valve with in-built regulator, flow meter, contains gauge and outlet pressure connector. -- Compact and lightweight : ideal for small cylinder -- Fully protected by an ergonomic plastic guard -- Filtration system ensures safety against ignition. -- Flow meter with orifice plate precision design increase high flow precision and low flow precision for pediatric patients PRODUCT...

 Open the catalog to page 8
MEDICAL CYLINDER VALVES-9

TECHNOLOGY OVERVIEW DETAILED FUNCTIONNALITIES OF OUR INTEGRATED VALVES VALVE INLET -- Anti dust tube according to the last amendment of EN ISO 10524-3 ·· Better protection of the valve against contamination and eliminates the risk of ignition in case accumulation of particles in a filter -- Excess flow device ·· Additional safety to avoid excess flow risks and optimize normal flow in use FILLING PORT -- Approved for 300 bar (tested at 360 bar) -- Active and non-active -- Spring in Copper Beryllium material highly compatible with oxidizing gases -- O-rings in EPDM -- High leak integrity due to...

 Open the catalog to page 9
MEDICAL CYLINDER VALVES-10

DETAILED FUNCTIONNALITIES OF OUR INTEGRATED VALVES REGULATOR SAFETY RELIEF DEVICE - Integrated into the regulator design ■ Quicker reaction - Large contact surface to increase sensitivity and reactivity to overpressure - No risk to damage the device - High flow through the device due to the large diameter and large venting holes FLOWMETER AND HOSEBARB -12 positions - Continuous flow even in between setting positions during handwheel operation - No possible positioning of the handwheel in-between settings - High precision of the flows -10 year life time without maintenance - Easy replacement of...

 Open the catalog to page 10
MEDICAL CYLINDER VALVES-11

TECHNOLOGY OVERVIEW CEODEUX MEDITEC INTELLIGENT ELECTRONIC SYSTEM CHANGE THE WAY YOU USE GAS GROUNDBREAKING INNOVATION TO PERFECTLY REACH OXYGEN THERAPY REQUIREMENTS: • Reactivity : Quick and accurate calculation of remaining time • Safety : Perfectly suitable for high pressure pure Oxygen environnement • Patient & Medical staff Services : Improved cylinders fleet management. - Quicker operations in emergency situations - Bluetooth for wireless communication • Optimization : Longer cylinder use thanks to accurate cylinder content management NEW CONTROL GAS USE THANKS TO INFORMATION TRANSPARENCY...

 Open the catalog to page 11
MEDICAL CYLINDER VALVES-12

HOW TO SELECT VALVES BODY MATERIALS Most Ceodeux Meditec valves are available in brass or chrome plated brass. Chrome plated or Raw brass: Gas Compatibility: make sure the body material is compatible with the gas type you will be using. The most commonly used material for high velocity oxygen applications due to its cost effectiveness, good strength, resistence and low-friction flow properties. Need more information? One of our material engineers would be happy to discuss the pros and cons of each option to help you choose the best solution. INLET PRESSURE Different models are designed for different...

 Open the catalog to page 12
MEDICAL CYLINDER VALVES-13

HOW TO SELECT VALVES To choose the right valve for your application and get the best results, you should identify the following technical parameters: TECHNICAL PARAMETER Working pressure Outlet pressure (only for VIPR) Gas type or medical mixture Material: raw brass or chrome plated Inlet connection: 17E, 25E, 3/14”-16 UNF Outlet connection valve- according to standards Filling port (only for VIPR): acc ISO 5145 or CGA V1.,... Residual pressure: if requested or no Gauge: if specific request Temperature range: -20°C/+65°C or specific Description of the final application: hospital homecare, emergency,...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.