General information Please read this manual carefully before use and follow the safety instructions to ensure your safety when using the mobile QuattroPower support handle. Keep these instructions for future reference and pass them on to other users! If the safety rules stated in the instructions for use are not observed, any liability on our part is excluded.

Open the catalog to page 2
QuattroPower Support Handles with Vacuum Safety Indicator - 3

Explanations/symbols in this manual and on the handle Follow the instructions for use! For persons with visual impairment, the font size for this on-line manual can be set accordingly at https://www.mobeli.de/download-bereich. Warning (indicates a dangerous situation) (additionally, year of manufacture on the handlebar) Order number Maximum user weight The mobile MOBELI grab handles are compliant with Regulation (EU) 2017/745 The mobile MOBELI grab handles are Class I medical devices Batch designation Allergy Notice: The high-quality rubber discs contain natural rubber latex. Natural rubber...

Open the catalog to page 3
QuattroPower Support Handles with Vacuum Safety Indicator - 4

Unfortunately, though, one cannot always rely on this assumption; therefore, it is absolutely indispensable to test the adhesive strength of the respective tiles or other surface materials on the wall beforehand. Furthermore, due to material ageing or in prefabricated construction there might be a reduction of the adhesive strength, therefore testing is essential (e.g., by abrupt application of force; with the help of another person, if necessary). Useful life The expected useful life is six years (if used daily and in accordance with the intended purpose) in an institution or public...

Open the catalog to page 4
QuattroPower Support Handles with Vacuum Safety Indicator - 5

Operation / assembly (Fig. 1) Push in the snap-lock pins from the bar connector (B) and insert into the short bar (C) until the snap-lock pin engages in the hole. (Fig. 2 arrow) Then insert the long bar (part D) into the bar connector (B). Insert the two bars (C and D) into the suction head connectors (A) (fig. 3). Test the secure hold of the snap-lock pins by trying to pull the components apart! The handle must not be used if not all snap-lock pins on both sides are securely locked. Attaching / suction (see pages 10 and 11) 1. 2. 3. Video unpacking Examine the vacuum suction pads and the...

Open the catalog to page 5
QuattroPower Support Handles with Vacuum Safety Indicator - 6

Technical data (For explanations of the symbols, see page 2) Above on the short grab bar Below on the long grab bar Thanks to the Mobeli modular system, the additional handle extension of 120 mm can also be retrofitted. Order no. 1400265S is without grab horn and order no. 1400266S is the QuattroPower support handle with grab horn. Maximum user weights in the table of technical data and on the handle bar must be observed! The mobile QuattroPower support handles have been developed to support natural movement. They are not designed to carry the full body weight Table of technical data Wall...

Open the catalog to page 6
QuattroPower Support Handles with Vacuum Safety Indicator - 7

Maintenance (service) If the handle has been attached to the wall for a prolonged period of time, the rubber discs will overstretch. We therefore recommend that you remove the handle from the wall approx. every 14 days and leave it overnight on a flat surface with the rubber disks relaxed, then reattach it the next morning. Examine the rubber pads for possible functional deterioration because of reduced elasticity due to age, wear, exposure to sunlight, uneven storage, scoring, etc. If the rubber pads are damaged and therefore the adhesive strength is limited, the complete suction heads...

Open the catalog to page 7
QuattroPower Support Handles with Vacuum Safety Indicator - 8

Video Disassembling QuattroPower

Open the catalog to page 8
QuattroPower Support Handles with Vacuum Safety Indicator - 10

Pictures for operation / assembly 12 11

Open the catalog to page 10
QuattroPower Support Handles with Vacuum Safety Indicator - 11

8.4 Images of the function of the vacuum safety indicator Vacuum safety indicator on the rocker arm 19 Adhesive strength too low! Suction head must be reattached immediately. Functionality of the safety rocker: The vacuum is permanently checked! Explanation of the symbols on the handles: Full security for the the specified maximum user weight. Attention! Attention: The handle must be reattached immediately! The vacuum of the handle is reduced. The handle is no longer permissible for the maximum user weight. (Only for your information: A reduced holding force is still present.)

Open the catalog to page 11
QuattroPower Support Handles with Vacuum Safety Indicator - 12

(Accessories are available from your specialist dealer.) To prevent unauthorised persons (e.g. demented persons, children, or in public areas) from opening the handle, we recommend our rocker arm safety lock. 1400674 (for 4 locks and 1 key). Rocker arm extension Flexible contrast rings Stainless-steel plates Video tilting lever lock Order no. 1400574, if the user’s strength is insufficient to actuate the rocker arm Order no. 1402766, for better contrast for visually impaired persons Order no. 1461418, for non-porous tiles Video rocker arm extension Toilet paper double holder 1400650 The...

Open the catalog to page 12

All ROTH MOBELI GmbH catalogs and technical brochures

  1. Mobeli Flyer

    2 Pages

Archived catalogs