A Rothacher Medical GmbH Instruction Guide WARNING-Read instruction guide before operating this equipment.
Open the catalog to page 1A Rothacher Medical GmbH
Open the catalog to page 2Please take time to familiarize yourself with your MIC oxygen concentrator before operating. Before using this product, make sure you have the following items: • 1 Adapter-for connect Humidifier bottle. • 1 Oxygen Outlet Connector Front View (Figure 1) 4. Circuit breaker — (selected units) resets the unit after electrical overload shutdown. 5. Flow meter knob 8. Oxygen outlet — oxygen is dispersed through this port 10. Nebulization outlet (according to the nebulization designed model exclusively) Back View (Figure 2) 11. Filter sponge — prevents dirt, dust, and lint from entering your unit 12....
Open the catalog to page 3a Rothacher Medical GmbH DISPLAY PANEL View (Figure 3) condition of system pressure (lo-p/hi-p) condition of oxygen purity (lo-o2 > total time that this device is operated low pressure / high pressure high temperature DISPLAY View (Figure 3) a. Power indicator (green light) b Normal oxygen (green light) c. Low oxygen (yellow light) Device is operating regulated Oxygen purity is under normal condition Oxygen purity is below 85%, ASK FOR SERVICE TURN this device OFF and contract your device supplier for service Nebulization Designed Model View (Figure 4 - 5) a. Nebulization is one of the optional...
Open the catalog to page 4Keep the oxygen concentrator at least 5 feet Cl.6 m)from hot, sparking objects or naked sources of flame. NOTE — Do not connect to an electrical outlet controlled by a wall switch. No other appliances should be plugged into the wall outlet. 2. Position your unit at least 6 inches (16 cm) from walls, draperies, or any other objects that might prevent the proper flow of air in and out of your oxygen concentrator. The Oxygen concentrator should be located so as to avoid pollutants or fumes. 1. Before operating your unit always checks to be sure the filter sponge is clean. 2. Attach the appropriate...
Open the catalog to page 53. Remove the power cord completely from the line cord strap, Make sure the power switch is in the “OFF" position, and insert the plug into the wall outlet. The unit is double insulated to guard against electric shock. Improper use of the power cord and plugs can cause a burn, fire or other electric shock hazards. Do not use the unit if the power cord is damaged. Oxygen causes rapid burning. Do not smoke while your oxygen concentrator is operating, or when you are near a person utilizing oxygen therapy. Keep the oxygen concentrator at Least 5 feet (1.6 m) from hot or sparking objects or naked...
Open the catalog to page 6Filter Sponge and Oxygen Outlet Connector The air filter and connector should be cleaned at least once a week. To clean, follow these steps: 1. Remove the filter sponge, which is located on the back of the unit. Remove the oxygen outlet connector 2. Wash in a solution of warm water. Don’t use any detergent. 3. Rinse thoroughly with warm tap water and towel dry. The filter should be completely dry before reinstalling. CAUTION — To prevent product damage, do not attempt to operate the unit without the filter sponge or while the filter sponge is still damp. Exterior Cabinet To avoid electric shock,...
Open the catalog to page 7Product Designation: Oxygen Concentrator Manufactory: Foshan MIC Medical Technology Co., Ltd EC authorized representation CGI Business Trading Inh. Herr Leizhang, Huegel Str. 73, 60433 Frankfurt am Main, Germany