1. Catalogs
  2. RSG Safety
  3. RSG F SERIES

RSG F SERIES

RSG F SERIES

RSG F SERIES

Product catalog summary
Description
The RSG F Series Particulate Respirators are disposable, cup-shaped, and flat-fold styled masks available with or without an exhalation valve. They comply with the European Standard EN149:2001 + A1:2009 and are available in FFP1, FFP2, and FFP3 classes. These respirators offer effective filtration with low breathing resistance, are collapse-resistant, and provide comfort with features like a soft foam interior and flexible nose clip.
Approval
The respirators comply with the EU 2016/425 Regulation for Personal Protective Equipment and are CE marked. They are approved by IFA Sankt Augustin, Germany (Notified Body number 0121).
Standards
The products meet the requirements of EN 149:2001 + A1:2009 for filtering facepiece respirators against particles. They are classified by filtering efficiency (FFP1, FFP2, FFP3) and clogging resistance. Performance tests include filter penetration, flammability, breathing resistance, and total inward leakage.
Designations
R = Reusable, NR = Non-reusable, D = Meets clogging resistance, OV = Odor and vapors < OEL value.
Applications
Suitable for use against solid and non-volatile liquid particles up to specified limits. Models include:
  • 200425: FFP1 NR D, No valve, Nominal Protection Factor 4
  • 200528: OV FFP2 NR D, With valve, Nominal Protection Factor 12
  • 200529: OV (Welding FR) FFP2 NR D + Ozone, With valve, Nominal Protection Factor 12
  • 200230: FFP3 NR D, With valve, Nominal Protection Factor 50
Materials
Components include elastic cotton straps, polyurethane nose foam, aluminum nose clip, polypropylene filter and valve, and thermoplastic elastomer valve diaphragm. No natural rubber latex is used.
Fitting Instructions
Ensure hands are clean before fitting. Inspect components for damage. Follow steps to secure the respirator and perform a fit check to ensure no air leaks.
Storage & Transportation
Shelf life is 5 years. Store in clean, dry conditions at -5°C to +25°C with <80% humidity. Use original packaging for storage and transport.
Disposal
Dispose of contaminated products as hazardous waste according to national regulations.
Warnings & Limitations
Ensure proper fit and use during exposure. Do not use in oxygen-deficient atmospheres or against unknown contaminants. Replace if damaged or at the end of the shift. Do not alter or repair the respirator.
See more

Catalog excerpts

RSG F SERIES-1

TECHNICAL DATASHEET RSG F SERIES PARTICULATE RESPIRATORS Discription Easily applied cup shaped and flat fold styled disposable respirators. Both single use face masks are available with and without an exhalation valve. The RSG filtering face pieces and particulate respirators meet the European Standard EN149:2001 + A1:2009 in FFP1, FFP2, and FFP3 classes of particulate filter efficiency. RSG maintenance free single use filtering respirators provide cost effective respiratory protection in hazardous workplaces and laboratories across a wide range of industries.           The respirator provides effective filtration with low breathing resistance for consistent high quality performance Dolomite dust test provides proven protection and comfort for a minimum of 8 hours. Collapse resistant; ideal for work in warm and humid environments. Stays securely in place - thus helping to provide a good, comfortable seal. Soft foaming on the inside of the mask feels comfortable on the skin. Specially designed nose clip which keeps its flexibility even after prolonged usage and fits any nose shape or size. Elastic cotton headbands do not cause skin irritation and will not lose flexibility or pressure in hot or cold working conditions. RSG Butterfly exhalation valve offers the lowest breathing resistance and improved comfort in hot humid environments and/or where work is hard and physical. Comfortable and easy to use for workers with a wide variety of work security equipment such as helmets, safety glasses, ear plugs etc. Extremely lightweight. Aproval These products comply with the EU 2016/425 Regulation for Personal Protective Equipment and are thus CE marked. Product approval by: IFA Sankt Augustin; Germany– Notified Body number 0121 Production Control 11A: IFA FA Sankt Augustin; Germany -Notified Body number 0121 Marking on the product: EN149:2001+A1:2009 CE0121 Standards These products meet the requirements of recently amended European Standard EN 149:2001 + A1:2009, filtering facepiece respirators for use against particles. They should be used to protect the wearer from solid and non-volatile liquid particles only. Products are classified by filtering efficiency and maximum total inward leakage performance (FFP1, FFP2 and FFP3), also by usability and clogging resistance. Performance tests in this standard include filter penetration; extended exposure (loading) test; flammability; breathing resistance and total inward leakage. Reusable products are also subjected to cleaning, storage and mandatory clogging resistance tests (clogging is optional for non reusable products). A full copy of EN 149:2001+A1:2009 can be purchased from your national standards body.

 Open the catalog to page 1
RSG F SERIES-2

TECHNICAL DATASHEET RSG F SERIES PARTICULATE RESPIRATORS Designations: R = Reusable NR = Non reusable (single shift use only) D = Meets the clogging resistance requirements OV = Odor and vapors < OEL value Aplications These respirators are suitable for use in concentrations of solid and non-volatile liquid particles up to the following limits: Model EN Classification Exhalation Nominal Protection 149:2001+A1:2009 Valve Factor 200425 200528 OV 200529 OV (Welding FR) 200230 200529 FFP2NR D Welding sparks. FFP1 NR D No FFP2 NR D Yes FFP2 NR D + Ozone Yes FFP3 NR D Yes mask is made from a flame retardant...

 Open the catalog to page 2
RSG F SERIES-3

TECHNICAL DATASHEET RSG F SERIES PARTICULATE RESPIRATORS 1. Hold the respirator in hand with the nosepiece at your fingertips. Allow headbands to hang freely below hand. 2. Cup the respirator firmly against your face with the nosepiece on the bridge of your nose. 3. Stretch and pull the lower headband over the head and position below your ears. Stretch and pull the top headband on the back of your head above your ears 4. Press soft nosepiece to conform snugly around the nose. 5. To test fit for respirator without exhalation valve: cup both hands over the respirator and inhale sharply. A negative...

 Open the catalog to page 3
RSG F SERIES-4

TECHNICAL DATASHEET RSG F SERIES PARTICULATE RESPIRATORS              Failure to follow all instructions on the use of these respiratory protection products and/or failure to properly wear the complete product during all periods of exposure may adversely affect the wearer’s health, lead to severe or life threatening illness or permanent disability. For suitability and proper use follow local regulations, refer to all information supplied or contact a safety professional/RSG Safety BV: www.rsgsafety.com. Before use, the wearer must be trained in use of the complete product in accordance...

 Open the catalog to page 4

All RSG Safety catalogs and technical brochures

  1. RSG FS SERIES

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.