1. Catalogs
  2. RTI Group
  3. Mako Specifications

Mako Specifications

Mako Specifications
1 / 12 PagesView full catalog

Mako Specifications

Product catalog summary
Introduction to Mako Sensor Technology
The document introduces the Mako sensor technology, highlighting its groundbreaking accuracy with a ±1.5% kVP uncertainty across the entire measurement range. The Mako Probes can be placed in any orientation within the X-ray beam, facilitating efficient measurements of kVp, time, HVL, total filtration, dose, and dose rate. This technology is applicable across all diagnostic X-ray modalities, including Radiography, Fluoroscopy, Mammography, CT, and Dental.

Plug and Play Simplicity
Mako offers plug-and-play simplicity, enhancing workflow efficiency. It is described as the world's most efficient meter with the highest practical accuracy and broad application range.

All-in-One X-ray Testing Solution
The Mako system includes the Mako meter, Mako Display, Ocean Next™ software, and a full probe lineup. It is designed to be future-proof, evolving with new functions and probes. The Mako Display provides fast, wireless touchscreen access to QA data, eliminating the need for a laptop.

Specifications Overview
  • General Specifications: The Mako system supports live measurement display on various devices, operates on Windows 10 and 11, and has a Bluetooth range of 100 meters. It requires only one exposure for measurements and comes with a 2-year warranty, extendable to 10 years.
  • Base Unit Specifications: The Mako Base Unit is compact and lightweight, with wireless and USB-C connectivity options. It operates on a rechargeable Li-ion battery with a 20-hour life.
  • Probe Specifications: Mako Probes are designed for versatility, with orientation-independent detector position checks and backscatter protection.


Detailed Specifications for Various Probes
  • Mammography Probe: Covers a tube potential range of 18-49 kV, with dose and dose rate uncertainties of ±5%.
  • R/F Probe: Supports a tube potential range of 35-155 kV, with similar dose and dose rate specifications as the Mammography Probe.
  • Dental Probe: Operates within a tube potential range of 35-125 kV, maintaining the same accuracy standards.


Additional Modules and Accessories
The document details specifications for various modules like the Ion Chamber Module, mAs Module, and Legacy Module, each compatible with specific probes and designed for specific measurement tasks.

Reference Conditions
Specifications are valid under reference conditions derived by RTI, with specific parameters for X-ray tubes and generators. The document also outlines the uncertainty of measurement, adhering to EAL Publication EAL-R2 standards.

Conclusion
The Mako system sets a high standard for quality assurance in X-ray imaging, emphasizing its importance to patients, professionals, and the industry.
See more

Catalog excerpts

Mako Specifications-1

Unparelleled performance and versatility. New sensor technology Experience the groundbreaking new sensor technology Mako Base Unit with Ion Chamber with best-ever accuracy, unrivalled in the market Module docked, and CT Ion Chamber attached. Instant measurments with (± 1.5% kVP uncertainty across entire measurement range). Place Mako Probes in any orientation in the X-ray beam, for the most efficient measurements of kVp, time, HVL, total filtration, dose and dose rate, while revelling in the captivation presentation of waveform data. Offering the broadest application range, across all diagnostic X-ray modalities (Radiography, Fluoroscopy, Mammography, CT and Dental). Simplified excellence with Plug n Play Mako adapts to your needs with plug-and-play simplicity, Mako Base Unit with R/F Probe boosting your entire workflow. It’s the world’s most docked, mAs Module connected efficient meter, with the highest practical accuracy and the broadest application range. All-in-one X-ray testing solution Mako is designed for modern X-ray equipment and tailored to your needs. The complete solution includes the Mako meter, Mako Display, Ocean Next™ software, and our full probe line-up. Future-proof by design, Mako evolves with new functions, probes, and an ever-expanding application range. The Mako Display gives you fast, wireless touchscreen access to QA data – no laptop required. With quick-access buttons, and easy export, testing is simpler than ever. If you prefer to use your own mobile device, download our app to connect wirelessly and get instant results directly on your phone. www.rtigroup.com

 Open the catalog to page 1
Mako Specifications-2

Live Measurement Display Mako display device (incl. tablet, laptop, PC) Software Ocean Next™ Operating System Windows 10, 11 Simultaneous Dose Measure Yes Bluetooth Range 100 m (free-in-air) ^Specifications in this document may be changed without notice Interface to Mako Display Wireless (Bluetooth) Interface to Probes USB-C connection Bluetooth Range 100 m (free-in-air) Power Source Rechargeable Li ion battery Battery Life 20 hours (practical measurement time) Battery Tested According to UN 38.3 Memory Unlimited

 Open the catalog to page 2
Mako Specifications-3

Mako Ion Chamber Module General Specifications Mako Probes (R/F, Mammo, Dental) General Specifications Size 122.5 x 28 x 14.5 mm Detector active areas Smallest 0.9 x 0.9 mm2, Detector position check Orientation independent, Compatible probes which can RTI CT Ion Chamber be connected to module: (10 cm and 30 cm) RTI DAP Chamber (86 x 86 mm and 147 x 147 mm), Ion Chamber Magna 1cc, and other Ion Chambers using Triaxial-to-Lemo adapter Unique detector design provides unbeaten angular sensitivity, offering the broadest range of use and best accuracy in practice. Compatible probes which can Mako mAs...

 Open the catalog to page 3
Mako Specifications-4

Mako R/F Specifications (R/F Probe) Mako Mammography Specifications (Mammo Probe)Tube Potential Range Min dose rate PPV and kVp Uncertainty Tube Potential Range Min dose rate PPV and kVp Uncertainty Dose Rate Range Resolution Trigg level Dose Rate Range Resolution Trigg level Min dose rate Uncertainty Min dose rate Uncertainty 1 nGy/s - 500 mGy/s 0.1 nGy/s 25 nGy/s @ exp. time >200 ms 3 |_iGy/s @ 1 ms 0.3 |_iGy/s @ 10 ms ±5 % or 1 nGy/s 50 nGy/s @ exp. time >200 ms 6 |_iGy/s @ 1 ms 0.6 |_iGy/s @ 10 ms ±5 % or 2 nGy/s Min dose rate Uncertainty Waveforms Range Resolution Bandwidth kV Bandwidth...

 Open the catalog to page 4
Mako Specifications-5

Mako Dental Specifications (Dental Probe) Min dose rate PPV and kVp Uncertainty Dose Range Range Resolution Trigg level Min dose rate Uncertainty Min dose rate Uncertainty Min peak dose rate Min pulse width Min peak dose rate Min pulse width 1 nGy/s - 500 mGy/s 0.1 nGy/s 25 nGy/s @ exp. time >200 ms 3 |_iGy/s @ 1 ms 0.3 |_iGy/s @ 10 ms ±5 % or 1 nGy/s Min pulse width Uncertainty Min pulse width Uncertainty Mako mAs Cable: 3m length Waveforms Range Resolution Bandwidth kV Bandwidth Dose Rate

 Open the catalog to page 5
Mako Specifications-6

Non-invasive mA and mAs specifications (Mako mAs Module with MAS-2) RTI CT Ion Chamber 10 & 30 cm Specifications (with Mako Ion Chamber Module) Connector type LEMO triaxial Cable 2 m, low noise triaxial Diameter 12 mm, 12.6 incl O-rings Time Range Min pulse width Uncertainty Min pulse width Uncertainty Radiation quality Energy dependence 0.01 mGycm - 9999 mGycm ±5 % or 0.01 mGycm Notice: Information within brackets ( ) are valid for the 30 cm chamber.

 Open the catalog to page 6
Mako Specifications-7

Ion Chamber Magna 1cc Specifications (with Mako Ion Chamber Module) RTI DAP Chamber Specifications 86x86 & 147x147 mm (with Mako Ion Chamber Module) Cable length 2.0 m (6.6 ft) Dose rate range Dose range Inaccuracy ±6 % at reference conditions Quality equivalent filtration (70 kV) 0.2 mm Al Dose Area Product Inner plate separation 8 mm Materials Air equivalent plastic, acrylic Entrance window Kapton conductive film Typical sensitivity 20 mGy/nC Dose Rate Range Resolution Bandwidth Uncertainty

 Open the catalog to page 7
Mako Specifications-8

RTI Light Probe Specifications RTI CT Dose Profiler Specifications (with Mako Legacy Module) (with Mako Legacy Module) Spectral Response CIE V(A) (Photopic) General specifications

 Open the catalog to page 8
Mako Specifications-9

RTI Dose Probe Specifications RTI T20 Specifications(with Mako Legacy Module) (with Mako Legacy Module) General specifications General specifications Dose rate Range 4 nGy/s - 150 mGy/s Range 1 nGy/pulse - 0.3 Gy/pulse Pulse rate/frequency Pulse width humidity relative humidity Temperate and air pressure Insensitive, no TP correction is necessary Angular dependence Very close to ideal Cosine (flat sensor) Dose rate Range 27 nGy/s - 500 mGy/s Pulse rate/frequency Typical energy dependence Range +1.6 to - 0.4 % (radiation quality R1)

 Open the catalog to page 9
Mako Specifications-10

C Mako Stand with Holders Mako Panoramic Dental Holder The Mako Stand with Holders has one Stand framework The Mako Panoramic Dental Holder is designed to hold with three different Holder configurations. the Mako Dental Probe in position during panoramic Holder A is compatible with the Mako R/F Probe, the dental measurements. Mako Mammo Probe and the Mako Dental Probe. Holder B is compatible with the RTI Dose Probe and RTI CT Ion Chamber (10 cm & 30 cm). Holder C is compatible with HVL filters provided with the Mako kits (dimensions 33 x 33 mm). The base of the Stand can also hold the Mako R/F,...

 Open the catalog to page 10