Catalog excerpts

Measurement speed unmatched by any other brand saving you time and money The DDM Series of Automatic Density Meters Rudolph Research Analytical serving its customers with Integrity Quality, and Innovation for over 50 years. See website for how above accreditations and warranty certifications apply
Open the catalog to page 1
The Simplicity of Touch Screen Measurement with the Flexibility of Windows® Oscillating U-Tube with Viscosity Correction and Reference Rudolph DDM Series Density Meters utilize an oscillating U-tube with full range viscosity correction and reference oscillator that allows for long term calibration stability and measurement at all temperatures with a single calibration (Patent # 7,735,353). Full Feature VideoView® with Automatic Scanning of Entire U-Tube Rudolph’s exclusive VideoView is protected under Patent #7,437,909 and provides superior high resolution visual bubble detection of your...
Open the catalog to page 2
The Simplicity of Touch Screen Measurement with the Flexibility of Windows® cGMP/GLP Calibration • alibrate the Rudolph DDM Series Density Meter with 2 or 3 points (e.g. C NIST Traceable Standards) as calibrating with merely air and water appears inconsistent with cGMP/GLP compliance regulations • bility to print out complete method configuration, communication A settings, as well as calibration verification and calibration adjustment data/history • nlimited number of customizable calibration verifications possible U • omplete History of Calibration Adjustments and Verifications are C...
Open the catalog to page 3
Unmatched Versatility, Traceability, Compliance and Flexibility For Highly Regulated Labs, Full 21 CFR Part 11 Instrument Level Compliance The United States Food and Drug Administration 21 CFR Part 11 regulation establishes the FDA’s requirements for electronic records and electronic signatures (ERES) to be trustworthy, reliable, and essentially equivalent to paper records and handwritten signatures. The Rudolph Density Meter user interface software’s 21 CFR Part 11 features fully supports and exceeds the requirements of 21CFR Part 11. Available in embedded and PC versions. The Rudolph...
Open the catalog to page 4
Unmatched Versatility, Traceability, Compliance and Flexibility NIST Traceable Calibration Standards Rudolph knows how important it is to calibrate with Traceable Standards and therefore, we include either a NIST or other National Physical Laboratory (NPL) traceable standard in the accessories provided with your density meter. The Rudolph DDM Series Density Meter includes all the accessories for immediate use*: • Quick Start Guide • Traceable Standard • IQOQPQ Documentation • Luer Syringes • Rinse/Sample Waste Container • User Manual • Filling Nozzles • Connecting Fittings & Tubing •...
Open the catalog to page 5
Choose the Sample Load Option Solution for Your Application Vertical Load • Sample injection is done vertically against gravity reducing air bubbles. Suitable for left and right handed operators as opposed to manual horizontal injection. Plunger is easier to push with all samples and there is more control over the syringe than with Horizontal Load. • Gives the ability to apply more pressure to the syringe when injecting viscous samples without harming operators. • Much easier cleaning. When a measurement is complete and the syringe is removed, gravity will force the sample down and into the...
Open the catalog to page 6
Choose the Sample Load Option Solution for Your Application LoadAssistTM • Great option as there are two ways to inject a sample: by manual vertical injection or having the PeriPump pull the syringe down for you. • Ideal for pulling the rinse solutions automatically into the system thus making the rinsing part of the operation much easier and independent. • Pressure mode available for carbonated samples. • Benefits customers that have multiple inexperienced users as the PeriPump will automatically inject the sample the same way every time. • No change in instrument’s performance when...
Open the catalog to page 7
Sample handling options for high throughput laboratories Peristaltic Pump Combining a Peristaltic Pump with a Rudolph Density Meter makes sample loading and cleaning faster and more convenient. A Peristaltic Pump draws the sample into the Density Meter and could also load a second instrument such as a Refractometer. The user drops a tube into the sample and starts the Peri Pump from the Density Meter display. The Peristaltic Pump draws the sample through one or two instruments and then measures automatically. The measured sample is displaced to waste by the following sample. Who Should Use...
Open the catalog to page 8
Sample handling options for high throughput laboratories Automate your Laboratory with a Rudolph Autoflex® R837 or R835 Automation System The DDM Series Density meters can be combined with various Rudolph Automation Systems and Sample Handling Accessories such as: Peristaltic Pump, ECS (Easy Clean System), Autofill®, Autoflex® R835 and Autoflex® R837 AutoSampler. The Rudolph Research R837 AutoFlex® is perfect for high throughput laboratories looking to increase productivity. The AutoFlex® R837 Sampler Features : • Customizable bottle size, Test Tube size such as: Boston Rounds:1oz, ½ oz,...
Open the catalog to page 9
Combine a Density Meter with a Refractometer for additional Measurements Test obscured Alcohol samples with Rudolph’s AlcoTest®-RI System. Long measurement needle and Peristaltic Pump make bottle measurement easy Obscured Alcohol samples are any solutions containing alcohol, water plus anything else such as flavoring or barrel aging. This includes beer, wines, flavored spirits and many barrel aged rums, whiskeys, and Bourbons. The AlcoTest®-RI measures the sample by calculating the density of the sample and then correcting for the obscuration using refractive index. The user can measure %...
Open the catalog to page 10
Densitometry The Rudolph DDM Series of Density Meters, with high precision Peltier temperature control of sample, has the features to meet the needs of today’s industrial applications. BEVERAGES, SPIRITS, WINE FOOD, FLAVOR, FRAGRANCE • The US TTB requires high accuracy for testing % Ethanol ABV in wine, beer, and spirits • The DDM 2911 Plus offers 0.01% accuracy for Ethanol testing • Direct and accurate means of °Brix determination, °Plato,°Balling, Proof, % Solids • easure Density, Specific Gravity M • hecking of raw materials and C product release • heck batch consistency and ensure C...
Open the catalog to page 11All Rudolph Research Analytical catalogs and technical brochures
-
Exclusive TempTrol™
16 Pages
-
AutoFlex ® R837
8 Pages
-
2019 VeriLinkRx
4 Pages
-
Alcotest® RI
6 Pages
-
The Autopol® IV
6 Pages
-
The Autopol® III
2 Pages
-
The Autopol® II
2 Pages
-
The Autopol® I
2 Pages
-
Autopol ® V PLUS
4 Pages
-
AutoPol
6 Pages
-
AutoFlex R837
4 Pages
-
AutoFill
4 Pages
-
ECS
2 Pages
-
VeriLinkRx
4 Pages
-
Refractometer Selection Guide
12 Pages
Archived catalogs
-
Density Meter DDM 2910
8 Pages
-
Density Meter DDM 2909
6 Pages