Saccharimeter Selection Guide
8Pages

{{requestButtons}}

Catalog excerpts

Saccharimeter Selection Guide - 1

Solutions for the Sugar Industry Saccharimeter Selection Guide Cane sugar milling and refining Beet sugar milling and refining Invert sugar Liquid sugar Confectionary sugar Molasses Brown sugar Ethanol Compliance with: ICUMSA GS1/2/3-2 ICUMSA GS1/2/3/9-1 • ICUMSA GS7-31 Rudolph Research Analytical, serving its customers with Integrity, Quality, and Innovation fo

Open the catalog to page 1
Saccharimeter Selection Guide - 2

The AUTOPOL® 589, 880, 880 PLUS and 880T provide 0.01 °Z repeatability and accuracy, time proven measurement technology and the critical features necessary for sugar analysis. Features Sugar Chemists Demand Rudolph Research Analytical knows that Sugar Technologists around the world demand 24 hour operation, 7 days a week. Regardless of the accuracy and budget demands, Rudolph Research has a solution. The reason we understand the sugar industry’s demands and requirements is because Rudolph has been serving the industry since 1940. Throughout those 75 plus years of service, Rudolph has...

Open the catalog to page 2
Saccharimeter Selection Guide - 3

Choosing a Cell and a NIST Traceable ICUMSA Compliant Calibration Standard Probe port Temperature measurement probe Measure point Temperature probe Waste exit Waste exit Probe port for temperature measurement Automation and continuous sampling All Autopol Saccharimeters come with a Temperature Probe so that sample temperature can be displayed and printed. The temperature probe is built into the sample compartment and can be inserted into the polarimeter cell. Cells are available in 25mm, 50mm, 100mm and 200mm optical pathlengths with necessary fittings for any application. Pour in sampling...

Open the catalog to page 3
Saccharimeter Selection Guide - 4

Choosing A Saccharimeter For Your Purity System Models Specification Highlights Autopol® 880 PLUS and 880T PLUS • Purity Software: Standard • Measurement Range: ±259°Z, ±89.9°Arc • Accuracy: 0.02°Z • emperature Correction: 20°C, T 27.5°C or user defined • Built-in Thermo Probe: Standard • Wavelength: 589nm • Prism: Glan Thompson Calcite • LED option available: 20-30mA, 100,000 hour average life For 0.02°Z accuracy applications where budget is critical and 589 nm is the only wavelength needed. This instrument is popular for sugar applications that do not require ICUMSA measurement at the 880...

Open the catalog to page 4
Saccharimeter Selection Guide - 5

Choosing A Refractometer For Your Purity System Models Specifications • Measurement Range: 1.32 - 1.53 RI / 0 - 100 Brix • Accuracy: ±0.00002 RI / ±0.01 BRIX • Electronic Temperature Control: Fixed temperature selection: 20°C and 25°C • Electronic Temperature Control: Selectable 10-65°C with CT-VT option Large Funnel Small Funnel WC Model Version wall mount Features and Benefits The J57HA’s simple interface and easy to clean prism surface make it one of our most popular models for the sugar industry. Temperature control to 20°C and 25°C makes it perfect for molasses and high Brix samples....

Open the catalog to page 5
Saccharimeter Selection Guide - 6

The AUTOPOL® models 589, 880, 880 PLUS and 880T always display Purity as if it were reading a 1 normal solution as defined in SPS-1: 3.1 The "normal sugar solution” is defined as 26.0160 g of pure sucrose weighed in vacuo and dissolved in water at 20.00°C to a final volume to 100.000 cm3. This corresponds to 26.000 g weighed in air under normal conditions (1013 mbar, 20°C, 50% relative humidity) and dissolved in water to a final volume of 100.000 cm3. Therefore, Rudolph displays: %Sucrose = °Z reading corrected for dilution Example: a 1/4 normal wt. solution reading 13.70°Z will read (4...

Open the catalog to page 6
Saccharimeter Selection Guide - 7

Measuring Purity Purity software is standard on the Autopol® 589, 880, 880 PLUS and 880T, just add a Refractometer and read BRIX, POL and PURITY simultaneously on the Autopol’s® large color backlit display. Autopol® 880 or Autopol 880 T Dual Wavelength Saccharimeter Large Color Backlit Display Sample Specific Programs The AUTOPOL® models 589, 880, 880 PLUS and 880T come with PURITY software and an unlimited number of methods which can be pre-defined for specific juices. This capability is advantageous in factory environments where the same type of samples are repeatedly measured. These...

Open the catalog to page 7
Saccharimeter Selection Guide - 8

Rudolph makes it easy to match a saccharimeter to your budget and For the more demanding accuracy applications, Rudolph offers the Autopol application. The Autopol IZ and IIZ were designed for limited budget 589, 880, 880 PLUS and 880T models that have ±0.01°Z (ISS) accuracy, OD applications where 0.02°Z (ISS) accuracy are sufficient. 4.0 dark sample penetration power and feature rich software. *Unless otherwise stated, specifications are based on 589nm Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail:...

Open the catalog to page 8

All Rudolph Research Analytical catalogs and technical brochures

  1. VeriLinkRx

    4 Pages

  2. AutoPol

    6 Pages

  3. AutoFill

    4 Pages

  4. ECS

    2 Pages

  5. VeriLinkRx

    4 Pages