Catalog excerpts

Technical parameter Optional accessories Section thickness range: 0.5 - 100 µm Trimming section thickness range: 1 - 800 µm Foot Switch Blade holder assembly Peltier element temperature: reduced to -50℃~-60℃ Specimen orientation: 8°(X-, Y-axis), 360°rotation of Number of freezing stations: 2 Electric coarse feed: 0-1800µm/s Stationary heat extractor Specimen retraction: 0-250µm, adjustable UVC disinfection: 30 or 180 minutes , user selectable pecimen feed: 28mm, vertical stroke: 70mm within 3 minutes, at chamber temp. -35℃ specimen disc Defrost: automatic defrost, manual defrost Cryochamber temperature range: 0~-35℃ ection mode: automatic section,manual section Specimen Cooling(optional)temperature range: -10℃~-50℃ Electric section mode: single、Cont.、Int.、Multi. Quick-freeze shelf minimum temperature: down to Storage system Microtome Blades-low profile FS800 For rotary microtomes and cryostats use FS800A Specimen cooling system Auto section Note For large specimen numbers and varying specimen types with UVC for increased user safety. Using PLASMA technology, sharp and durable You can choose different configurations and functions according to your own needs. Width(with handwheel) x Depth x Height:835*1000*1215mm Number of freezing stations: 15 Pathology consumables Electric section speed : 0.5~450mm/s Most popular cryostat with individually controlled temperature settings on both the cryochamber and the specimen holder. With vacuum cleaning system for optimized safety. With motorized section to improve reproducibility. Fully automatic cryostat with vacuum clea
Open the catalog to page 1
Stable temperature Stable section quality adjustable. Compressor adopts frequency guarantee for section smoothness and accuracy. control. Open the glass for more than 2 hours, the injection requirements. The precision cross roller guide rails provide conversion working mode, intelligent temperature temperature fluctuation within 2℃. Precise screw rod meets the 0.5μm sample The five-phase high-resolution stepping motor has higher positioning accuracy and lower motor Effective specimen cooling system(optional), the temperature -10℃~-50℃ adjustable. With low pressure cooling system and...
Open the catalog to page 2All RWD Life Science catalogs and technical brochures
-
RWD Gradient Thermal Cycler
2 Pages
-
Rotary Microtomes S710
2 Pages
-
RWD Osmotic infusion Pump
2 Pages
-
RWD Syringe Pump R462
1 Pages
-
RWD Rotating impactor 68099Ⅱ
2 Pages
-
RWD Microcentrifuge M1324R
2 Pages
-
RWD Infusion imager RFLSI Ⅲ
2 Pages
-
RWD Surgical Instruments
18 Pages
-
RWD Veterinary medical equipment
32 Pages
-
RWD R415 Animal Ventilatorr
1 Pages
Archived catalogs
-
PRODUCT CATALOGUE 2017
51 Pages
-
2015 Product Catalogue
44 Pages