Introduction
The R820 Tri-Color Multichannel Fiber Photometry System is designed for monitoring neuronal activity through fluorescence intensity changes in specific brain areas. It supports long-term stable monitoring of neurons in freely moving animals, aiding in the study of neural circuits and their correlation with behavior.

Product Features
The system utilizes three excitation light sources (410nm, 470nm, and 560nm) for reference, green, and red fluorescence. It supports up to 9 channels for simultaneous experiments on multiple animals or brain locations. Dual detectors ensure accurate signal acquisition by avoiding interference. The system includes professional software for data acquisition and analysis, eliminating the need for Matlab programming.

Product Parameters
  • Wavelengths: 410nm, 470nm, 560nm
  • Channels: 9
  • Frame rate: Max 300fps
  • Signal interface: 4 Input, 4 Output
  • Signal output: Adjustable frequency 0-500Hz
  • Behavior camera resolution: 1920x1080 (30fps), 1280x720 (60fps)

Standard Configuration
The system includes a host, power cord, USB cables, software, and various optical components. Optional accessories include fiber-optic cannulas and laser power meters.

Hardware Functions
The system features 4 input and 4 output ports for TTL signal triggers, dual detectors for fluorescence detection, and a stable LED light source. It supports various optical fiber sizes and provides a lightweight design.

Software Functions
The software offers stable data acquisition and processing capabilities, including data clipping, bleaching correction, and event heat map generation. It supports data export in various formats and allows for flexible event handling and comparison.
See more

Catalog excerpts

RWD TriColor Multichannel Fiber Photometry System R820-1

Standard Configuration Product Features CONTRIBUTE WISDOM AND STRENGTH TO THE IMPROVEMENT OF QUALITY CONTRIBUTE WISDOM AND STRENGTH TO THE IMPROVEMENT OF QUALITY Three kinds of excitation light sources, that is 410nm、470nm and 560nm, are respectively used for excitation Fiber Photometry Main Device Optical fiber Fiber Cannula sleeves Behavior Camera Supports multiple acquisition modes including continuous acquisition, interval acquisition, acquisition upon Behavior Camera bracket Live display of DeltaF/F acquisition to check scale of signal changes during acquisition; of reference, green fluorescence and red fluorescence; Support up to 9 channels, suitable for simultaneous experiment of multiple animals or multiple brain locations; Dual highly sensitive detectors enabling independent and sequential detection to avoid interference of fluorescence excitation and detection, acquiring more accurate signal; Professional acquisition and analysis softwares are flexible and easy to operate with data processing functions available. No matlab programming is required; trigger, delayed acquisition and timing acquisition; Supports simultaneous video acquisition of behaviors with multiple cameras; Photobleaching device Includes: Host, power cord, 3 USB cables, USB expansion interface, software U disk Includes pre-installed software, I5-10500H/16G/ 500G/WIN10(1920*1080) Low Autofluorescence Fiber-optic Patch Cords 200um/ 0.37NA/2m,Ф1.25mm or Ф2.5mm Black Ceramic Sleeves, Φ1.25mm or Φ2.5mm Record video of animal behavior and identify animal tracks,USB3.0,3M Adjustable height range0.8-1.5m,Rotation Angle 360° FC/PC Patch Cord photobleaching machine(R810-1) Software key(Not for analysis function) Customized adjustment of output signal parameter, easily trigger and control external excitation equipment to achieve closed-cycle control of excitation and recording. Product Parameters Optional Accessories:Fiber-optic Cannula, Branching Fiber-optic Patch Cord, Laser power meter and CONTRIBUTE WISDOM AND STRENGTH TO THE IMPROVEMENT OF QUALITY Wavelength of excitation light Power Number of channels Min 0µW, Max≥100µW, adjustable with an accuracy of 0.1µW 9 Frame rate of fluorescent sampling Digital signal interface Signal output Output frequency 0-500Hz, adjustable output pulse width and duration Marking Behavior camera Manual marking (10), automatic marking (4), ROI marking (9) 1920*1080(30fps) 1280*720(60fps) Switchable among multiple frame rates of resolution Ceramic Ferrule Holder etc. Client List CONTRIBUTE WISDOM AND STRENGTH TO THE IMPROVEMENT OF QUALITY

 Open the catalog to page 1
RWD TriColor Multichannel Fiber Photometry System R820-2

CONTRIBUTE WISDOM AND STRENGTH TO THE IMPROVEMENT OF QUALITY The fiber photometry system records changes in the fluorescence intensity of neurons in a specific brain area to reflect neuronal population activity. In the study of neural circuits, the fiber photometry system can perform Software functions CONTRIBUTE WISDOM AND STRENGTH TO THE IMPROVEMENT OF QUALITY Professional acquisition and analysis softwares CONTRIBUTE WISDOM AND STRENGTH TO THE IMPROVEMENT OF QUALITY long-term stable monitoring of the neurons of freely moving animals, and explore the correlation between neural activity and animal...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.