SV 2
20Pages

{{requestButtons}}

Catalog excerpts

SV 2 - 2

PRESENTATION OF MANUAL INSTRUCTIONS FOR USE Technical Name: Vacuum Pump for Dental Set Trade Name: Vacuum Pump Model: SV2 Brand: Saevo Manufacturer / Distribuitor: Alliage S/A Indústrias Médico Odontológica C.N.P.J. 55.979.736/0001-45 - Insc. Est. 582.002.897.114 Rod. Abrão Assed, Km 53+450m - Cx. Postal 782 CEP 14097-500 Ribeirão Preto - S.P. - Brasil Telefone +55 (16) 3512-1212 Technical Duties: Daniel R. de Camargo CREA-SP: 5062199650 For improved safety: Read and understand all the instructions contained in the Instructions for Use before installation or operation of this equipment....

Open the catalog to page 2
SV 2 - 3

INDEX 02 PRESENTATION OF MANUAL 04 IDENTIFICATION OF EQUIPMENT 04 Indication of Equipment 04 Purpose of the equipment 05 Description of Equipment 06 MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION 07 TECHNICAL SPECIFICATIONS 07 General features 08 Dimensions 10 Packing symbols 10 Product symbols 11 INFRA-STRUCTURE SPECIFICATION 11 INSTALLATION OF EQUIPMENT 13 EQUIPMENT OPERATION 14 PRECAUTIONS, RESTRICTIONS AND WARNINGS 14 Recommendations for preserving the equipment 14 Transportation, storage and operation 14 Sensitivity to predictable environmental conditions in ordinary...

Open the catalog to page 3
SV 2 - 4

IDENTIFICATION OF EQUIPMENT Dear Customer Congratulations. You have made a good choice when you decided to buy a SAEVO QUALITY product comparable to the best products available in the World. This manual is a general presentation of your product and it will give you important details to help you to solve possible problems. Please, read it and keep this with you. Technical Name: Vacuum Pump for Dental Set Trade Name: Vacuum Pump Model: SV2 Brand: Saevo This equipment is for dental use use only. It must be operated and utilized by specialized professional (certified professional, according to...

Open the catalog to page 4
SV 2 - 5

IDENTIFICATION OF EQUIPMENT Description of Equipment Was designed to supply bio-safety needs on the dental activity. Equipment with high suction power, that absorves with more efficiency the saliva and residues. Built in bronze-aluminum alloy, high resistant to corrosion, which allows years of use on a daily basis. Steel structure, covered with resistant material, and easy cleaning round corners. 1/2HP 0,37 KW, power, allowing to operate until 2 dental office simultaneous. DEBRIS FILTERING SYSTEM. Located on the suction inlet of the pump. This system guarantees greater safety, avoiding jams...

Open the catalog to page 5
SV 2 - 6

MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION The contents of this page are of an informative nature, the equipment being able to differ from that illustrated. So, upon acquiring the product check the technical compatibilty between equipment, coupling and accessories. side view 01 - Box of the Electric Command 02 - Engine with Thermal Protection 03 - Niple entrada água 04 - Water flow regulator 05 - Outlet (to drain) 06 - Suction inlet 07 - Pump residues filter 08 - Base of the Pump 09 - Body of the Pump * 10 - Kit SV2 * 11 - Kit SV4 * 12 - Kit Damper * 13 - Kit Finishing Cover...

Open the catalog to page 6
SV 2 - 7

TECHNICAL SPECIFICATIONS General features Model SV2 Power supply voltage 110-127 / 220V~ (Bivolt - Selector Switch) Frequency 50/60 Hz Nominal Power (Maximum) 1220 VA Nominal Current 110V/50Hz 220V/50Hz 127V/60Hz 220V/60Hz Tension of the Command 24Vdc Thermal protection Safety device for protection against engine temperature rise Motor 1/2 HP RPM 110/220V/50Hz - 2930 127V/60Hz - 3550 220V/60Hz - 3520 Electric shock protection type Class one equipment - Applied Part Type B Protection against harmful water penetration or particulate material IPX0 Maximun Vacuum 400 mm/Hg Consumption of Water...

Open the catalog to page 7
SV 2 - 8

TECHNICAL SPECIFICATIONS Gross weight (Vacuum Pump) 22 Kg Net weight (Kit Vacuum Pump) Kit SV2 = 0,9 Kg / Kit SV4 = 2 Kg Gross weight (Kit Vacuum Pump) Kit SV2 = 1,4 Kg / Kit SV4 = 2,67 Kg Pay attention while using this equipment together with other movable equipment, in order to avoid collisions.

Open the catalog to page 8
SV 2 - 9

TECHNICAL SPECIFICATIONS Dimensions (mm) Kit SV4

Open the catalog to page 9
SV 2 - 10

TECHNICAL SPECIFICATIONS Packing symbols It determines the maximum quantity of boxes which can be stacked during transportation and storage “as per packaging”. Packing to be transported and / or stored avoiding humidity, rains and wet floor. Packing to be transported and / or stored with the harrows up. The packing must be stored and transported away from direct sun light exposure. Packing to be transported and / or stored with care (should not suffer drop and neither receive impact). Temperature limit for the packing to be stored or transported. Product symbols Applied part type B....

Open the catalog to page 10
SV 2 - 11

INFRA-STRUCTURE SPECIFICATION The perfect functioning and the durability of the Saevo dental office are directly linked to the preinstallation, which must be carried out by duly trained professionals according to the instructions contained in the "Pre installation plan" which is found with the Saevo authorized technical representative. INSTALLATION OF EQUIPMENT The installation of this equipment requires the necessity of specialized technical assistance (Saevo). Ask for the presence of a Saevo representative technician at the nearest seller, or through the Saevo Service Center: + 55 (16)...

Open the catalog to page 11
SV 2 - 12

INSTALLATION OF EQUIPMENT Connection points The vacuum pump can be installed inside the office, in a room next to the office or in an engine room. It is important that the chosen location is protected from moisture, sun rays and good ventilation. There are two options for installation. - Option 1: Vacuum pump located besides the connecting box (Dental Set model with integrated connection box). - Option 2: Vacuum pump located inside a cabinet. For installation inside the Dental Set, next to the connection box (Option 1), we recommend using the finish cover kit to reduce the noise of the...

Open the catalog to page 12
SV 2 - 13

INSTALLATION OF EQUIPMENT To install the vacuum pump, consider the following points. C. WATER: PVC tube welding acceptable Ø 20 mm, glove at the tip with tin plug of Ø 20 X 1/2 ” in contact with the floor connected to the water supply. F. SUCTION: PVC tube welding acceptable Ø 25 mm, glove at the tip with tin plug of Ø 25 x 3/4” in contact with the floor connected to the point “F” of the connection box. E. DRAINING: PVC tube welding acceptable Ø 40 mm, glove at the tip with tin plug of Ø 25 x 3/4” in contact with the floor connected to the inspection box (with a minimum decline of 2%). This...

Open the catalog to page 13

All SAEVO catalogs and technical brochures

  1. SV 4

    20 Pages