Overview: The DIF O.T. ceiling filtration system is designed for operating theatres to ensure environmental sterility by controlling airborne particles and maintaining comfort for the surgical team. It is crucial in preventing wound infections by filtering and distributing air effectively around the surgery table.
Specifications: The system uses H14 efficiency HEPA filters for absolute air filtration and unidirectional airflow with differential velocities to maintain ISO Class 5 sterility during operations. The airflow decreases from the center to the perimeter, ensuring aseptic conditions and comfort for the surgical team.
Key Features: The system offers fast particle decontamination, energy efficiency, and easy installation without physical barriers. It includes a reverse liquid seal for airtightness and modular versions for transport and assembly. Air return grilles are strategically placed for optimal air circulation.
Standards and Compliance: The system complies with various international standards, including ISO 14644-1, SWKI 99-3, and others from Italy, France, Germany, and more. It is certified for ISO 5 operational conditions.
Performance: The system achieves low particle concentration and fast recovery times, as confirmed by tests using optical particle counters and biological concentration counters. It maintains high performance with low pressure drops and no micro-turbulence.
Design and Construction: Constructed with AISI 304 stainless steel, the system includes a patented flow equalizer for uniform air distribution. It is available in standard and custom sizes, with a nominal airflow of 9,500 m3/h.
Applications and References: The DIF O.T. system is used in major health facilities across Italy and internationally, including hospitals in Barcelona and Switzerland.
Company Commitment: SagiCofim emphasizes sustainability, offering products that ensure health, comfort, and energy savings. Their environmental management system is ISO 14001 certified, focusing on high efficiency, low pressure drop, and recyclable materials.
See more

Catalog excerpts

DIF OT_LS-1

DIF O.T. Ceiling filtration system for operating theatres

 Open the catalog to page 1
DIF OT_LS-2

Air filtration and distribution for operating theatres The operating rooms are the hospital areas where it is required the most accurate control of the environmental sterility. As the highest source of bacteria is coming from the medical staff during the operation, the highest concentration of contaminants is located around the surgery table, increasing the risk of wound infections. The concentration of microrganisms is taken as an index of sterility of the environment and it is expressed in number of particles carrying microrganisms. The choice of the air filtration and distribution system for...

 Open the catalog to page 2
DIF OT_LS-3

The DIF-O.T. ceiling filtration system is the result of the know-how developed by SagiCofim in the techniques of air filtration and distribution for operating rooms. This system, thanks to H14 efficiency absolute filters, allows a controlled air distribution above the operating theatre and represents the best choice to control the contamination levels. Its peculiarity is the capability to guarantee the sterility levels in ISO Class 5 Operational Simulated, i.e. during the intervention, with the surgical team fully operative. This result is achieved thanks to a sophisticated supply air concept...

 Open the catalog to page 3
DIF OT_LS-4

• Unidirectional airflow from the ceiling with differential velocities • Air filtration through absolute HEPA filters • No physical guides or air curtains are required. • No uncomfortable drafts in the occupied zone • No contaminated air induction in the critical zone • Class ISO 5 “Operational simulated” guaranteed, during the surgical room operation, certified according to the Swiss Standard SWKI 99-3. • Perfect tightness by means of a reverse liquid seal around the edge of the filters Air return grilles are located in the four corners of the room in two locations: at the floor and at the ceiling...

 Open the catalog to page 4
DIF OT_LS-5

• Complete system for ceiling air filtration and distribution, factory assembled and tested. • Standard dimensions: 3,2 m x 3,2 m x 0,4 m, nominal air flow 9.500 m3/h 1 • Holding structure, filter frames and top plenum made of AISI 304 stainless steel. • HEPA filters, H14 efficiency, with different performance and colours (V1, V2, LV) designed to obtain a decreasing air velocity from the centre towards the perimeter of the surgical theatre. • Patented flow equaliser to achieve uniform and constant air distribution over the whole surface even with low velocities. • Perfect tightness guaranteed...

 Open the catalog to page 5
DIF OT_LS-6

High performance system Fast recovery time A DIF-O.T. fitted in SagiCofim mock-up room was tested by specialised personnel using an OPC (Optical Particle Counter) and a biological concentration counter. The diagrams show the test results in terms of 0,5 micron diameter particles and CFU (Colony Forming Units). These data were confirmed during the tests carried out on site and certified by independent laboratories. Colony Forming Unit CFU/m3 tempo - minuti tempo - minuti The diagram shows the results of the particle count above the operation table. The test has been conducted using an OPC following...

 Open the catalog to page 6
DIF OT_LS-7

Design description Standard size 3,2 m x 3,2 m x 0,4 m Rated data Nominal airflow: 9.500 m3/h Initial pressure drop: 80 Pa Final pressure drop: 350 Pa Performance ISO 5 Operational simulated according to the Standards SWKI 99-3 (2004), VDI2167(2004) e DIN 1946-4 (2008) Ceiling filtration system for operating theatres with unidirectional airflow with differential velocities, decreasing from the centre towards the perimeter, to provide a dynamic barrier between the operating table and the outer zone. Class ISO 5 according to ISO 14644-1 “Operational simulated” during the surgical room operation,...

 Open the catalog to page 7
DIF OT_LS-8

think green. A complete range Following an approach based on sustainability, SagiCofim is committed to developing and offer the market a full range of product and solutions for comfort and process applications, to meet our customers' needs, without compromising the current and the future environment and to allow next generations to meet their own needs. Through the years our mission has always been the same: provide health, comfort and energy saving, by developing integrated high tech solutions for air filtration, treatment and distribution. For us, sustainability is a powerful energy management...

 Open the catalog to page 8

All SagiCofim catalogs and technical brochures

  1. LS-KS

    1  Page

  2. DUG-B_DUG-A

    2  Pages

  3. SA SA - LF

    2  Pages

  4. LMG - KMG

    1  Page

  5. AH-AS

    1  Page

  6. INER-ST

    8  Pages

  7. MPS

    2  Pages

  8. PK

    3  Pages

  9. JD

    3  Pages

  10. FLG

    2  Pages

  11. CANISTER

    4  Pages

  12. SMBA

    2  Pages

  13. SFD-SFDT

    16  Pages

  14. CARBO

    1  Page

  15. PFA6/6/7/8/9

    1  Page

  16. PFA/4-PFA/5

    1  Page

  17. CAP

    1  Page

  18. MULTIMOD

    1  Page

  19. MODULO

    1  Page

  20. CT

    1  Page

  21. SAF

    1  Page

  22. CAB

    1  Page

  23. DIF O.T.

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.