M167
1 / 1Pages

Catalog excerpts

M167 - 1

M167 Sakamoto Airway Management Trainer ● Weight/About 14kg  ● Case size/ W83×D52×H29cm ● Accessories/ Front teeth (3 sets) Lubricant oil, Baby powder, Storage case , 1. Realistic practice possible Same movement as the human body reproduced Neck flexion and Head extension A model with anatomical reality Suitable for practical training of tracheal intubation. Neck flexion and Head extension ● It is possible to acquire the skill of both oral and nasal tracheal intubation. ● It is possible to acquire the skill of supraglottic airway devise (such as Laryngeal mask airway, the esophageal gastric tube airway). ● The tongue, epiglottis and the pharynx Epharynx have been reproduced such as a real living body. ● Because the tongue and mouth are soft, usage of laryngoscope and training in securing the airway can be done in a manner close to a living body. Confirmation of mistakenly intubated air possible rise 2. Damage of front teeth When using a laryngoscope, if pressure is put, using the teeth as a fulcrum, in a mistaken normal teeth manner, the front teeth (upper four) are made to broken teeth break. (The front teeth are exchangeable.) 3. Confirmation of left and right air sound possible When correctly intubated and ventilated, you can confirm the left and right chests rise. ● Can confirm one-lung ventilation. ● Can confirm accidental esophageal intubation When intubated are ventilated one lung, you can confirm the error, as only one side will rise. The closeness to a real living body, Makes realistic training possible The position of the pharynx, larynx, and epiglottis in relation to the cervical vertebra, and anatomical elements such as the axis of the oral cavity "pharynx" larynx have been taken into consideration. Not only durability, but also the delicacy of the human body has been considered, making it close to a real living body. Parts of the model are purposefully make to be damaged if handled roughly. 23 Internal strycture▲ Exchangeable parts Exchangeable part (front teeth) 3sets/one set When the tracheal tube has been mistakenly intubated into the esophagus and air is sent, the abdomen will rise, making it possible t

Open the catalog to page 1

All Sakamoto Model Corporation catalogs and technical brochures

  1. M177

    1 Pages

  2. M106-1

    1 Pages

  3. M206

    2 Pages

  4. M172

    1 Pages

  5. M152

    1 Pages

  6. M169

    1 Pages

  7. M151

    1 Pages

  8. M193-1

    2 Pages

  9. M186

    2 Pages

  10. M156

    1 Pages

  11. M192

    2 Pages

  12. M155

    1 Pages

  13. M152-2

    1 Pages

  14. M160

    2 Pages

  15. M100-2

    1 Pages

  16. M165-1.2

    2 Pages

  17. M176-6.7.8.9

    2 Pages

  18. M148-3

    1 Pages

  19. M181

    2 Pages

  20. M183

    2 Pages

  21. M179

    2 Pages

  22. M103

    2 Pages

  23. M104

    2 Pages

  24. M102

    2 Pages

  25. M195

    1 Pages

  26. M194

    2 Pages

  27. AM-1

    1 Pages