RAC Technical Data Book Wind Free RAC for North America (R410A, HP) Model: AR###SW##WKNCV (Indoor Unit) AR###SW##WKKCV (Outdoor Unit)
Open the catalog to page 1Model Name
Open the catalog to page 36. Temperature and airflow distribution 23
Open the catalog to page 4® NOTE • NominalCooling : Indoortemperature 26.7°C DB/19.4°C WB(80°F DB/67°FWB), Outdoortemperature 35°C DB/23.9°C WB(90°F DB/75°F WB), Refrigerant pipe length 7.5m(24.6ft), Level difference Om(Oft). • Nominal Heating : Indoortemperature 21.1°C DB/15.6°C WB(70°F DB/60°F WB), Outdoortemperature 8.3°C DB/6.1°C WB(47°F DB/43°F WB), Refrigerant pipe length 7.5m(24.6ft), Level difference Om(Oft). • Sound level was acguired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. • Specifications may be subject to change without prior notice.
Open the catalog to page 6® NOTE • Specification may be subject to change without prior notice.DB/23.9°C WB(90°F DB/75°F WB), Refrigerant pipe length 7.5m(24.6ft), Level difference Om(Oft). 1) Performances are based on the following test conditions. - Cooling : Indoor temperature : 80°F(26.7°C) DB, 67°F(19.4°C) WB, Outdoor temperature : 95°F(35°C) DB, 75°F(23.9°C) WB - Eguivalent refrigerant piping length 5m(16.4ft), Level differences : Om(Oft)) 2) Select wire size based on the value of MCA - Sound pressure level is a relative value, depending on the distance and acoustic environment. - dBA = A-weighted sound...
Open the catalog to page 8Cooling TC (Total Capacity), SHC (Sensible Heat Capacity), PI (Power Input) • The performance table shows the average value of each conditions. 9
Open the catalog to page 9Cooling TC (Total Capacity), SHC (Sensible Heat Capacity), PI (Power Input) • The performance table shows the average value of each conditions. 10
Open the catalog to page 10Cooling TC (Total Capacity), SHC (Sensible Heat Capacity), PI (Power Input) • The performance table shows the average value of each conditions. 11
Open the catalog to page 11Cooling TC (Total Capacity), SHC (Sensible Heat Capacity), PI (Power Input) • The performance table shows the average value of each conditions. 12
Open the catalog to page 12© NOTE • This wiring diagram applies oniy to the indoor unit. • Colors BLK : black, BRN : brown, SKY-BLU : sky-blue, GRN/YEL : green/yeiiow, RED : red, YEL : yellow, ORG : orange, BLU : blue, WHT:white • For connection wiring indoor-outdoor transmission 3(C), refer to the installation manual • ® : Protective earth(screw)
Open the catalog to page 18DOWNLOAD ECO-CCMM oeoi MMTJ cwei COMNb^V rw-ir; rj-T CN23S (BLK) MAIN DOWNLOAD QNSV1 CVKI- NDOOR UNIT # N0TE1 - THERMISTOR MARK BASED ON THE TEMP 25#C 0 NOTE • This wiring diagram applies oniy to the indoor unit. • Colors BLK : black, BRN : brown, SKY-BLU : sky-blue, GRN/YEL : green/yeiiow, RED : red, YEL : yellow, ORG : orange, BLU : blue, WHT:white • For connection wiring indoor-outdoor transmission 3(C), refer to the installation manual • ® : Protective earth(screw)
Open the catalog to page 190 NOTE • This wiring diagram applies oniy to the indoor unit. • Colors BLK : black, BRN : brown, SKY-BLU : sky-blue, GRN/YEL : green/yeiiow, RED : red, YEL : yellow, ORG : orange, BLU : blue, WHT:white • For connection wiring indoor-outdoor transmission 3(C), refer to the installation manual • © : Protective earth(screw)
Open the catalog to page 20Indoor unit Sound Pressure level 0 NOTE • Specifications may be subject to change without prior notice. • Sound pressure Level - Sound pressure level is obtained in an anechoic room. - Sound pressure level is a relative value, depending on the distance and acoustic environment. - Sound pressure level may differ depending on operation condition. - dBA = A weighted sound pressure level - Reference acoustic pressure OdB = 20pPa
Open the catalog to page 21Outdoor unit Sound pressure level ® NOTE • Specifications may be subject to change without prior notice. • Sound pressure Level - Sound pressure level is obtained in an anechoic room. - Sound pressure level is a relative value, depending on the distance and acoustic environment. - Sound pressure level may differ depending on operation condition. - dBA = A weighted sound pressure level - Reference acoustic pressure OdB = 20pPa
Open the catalog to page 22Cooling Discharge angle : 16 1) Cooling air velocity distribution Heating Discharge angle : 46°
Open the catalog to page 23Cooling Discharge angle : 16 1) Cooling air velocity distribution Floor distance Heating Discharge angle : 46°
Open the catalog to page 246. Temperature and air flow distribution AR18NSWXCWKNCV 1) Cooling air velocity distribution 2) Cooling Temperature distribution 3) Heating air velocity distribution 4) Heating Temperature distribution
Open the catalog to page 256. Temperature and air flow distribution AR24NSWXCWKNCV 1) Cooling air velocity distribution 2) Cooling Temperature distribution 3) Heating air velocity distribution 4) Heating Temperature distribution
Open the catalog to page 26OUTDOOR UNIT INDOOR UNIT Indoor ThermistorIndoor Room Fan Motor (IFM) (T_IR) Service ValveGas Pipe (SV_G) Thermistor IDU Heat Exchager Mid (T_IM) Thermistor- Outdoor Fan Motor (OFM) Ambient (T_A) Electronic Expansion Valve Main (E_M) Heat Exchanger Main(Outdoor unit) (HX_M) ThermistorIDU Heat Exchanger IN (T_II) Heat Exchanger Indoor unit (HX_ID) Service ValveLiquid Pipe (SV_L) Compressor (COMP)
Open the catalog to page 27© NOTE • The assumed installation conditions are follows - The pipe length (including elbow) is 24.6 ft. - The level difference is 0 ft.
Open the catalog to page 282018. Ver. 2. Samsung Electronics Co., LTD. B2B PM / SE Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677 Website : www.samsung.com, http://btsp.samsunggsbn.com Email : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.
Open the catalog to page 30All Samsung HVAC catalogs and technical brochures
-
360 Cassette
12 Pages
-
DVM S Water
8 Pages
-
DVM S Eco Brochure
8 Pages
-
DVM Chiller
8 Pages
-
Max Heat Brochure
12 Pages
-
DVM S Water Brochure
8 Pages
-
DVMS Catalog
8 Pages
-
SUBMITTAL AM528JXVAJH/AA
3 Pages
-
SUBMITTAL AM288JXVAJH/AA
3 Pages
-
SUBMITTAL AM216KXVGJH/AA
2 Pages
-
SUBMITTAL AM144FXVAJH/AA
2 Pages
-
SUBMITTAL AM072FXVAFH/AA
2 Pages