SUBMITTAL AM288JXVAJH/AA - 1

1 of 3 SUBMITTAL AM288JXVAJH/AA Samsung DVM S Series, Heat Pump Condensing Unit Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # System Specifications Modules Connected Nominal / Rated Cooling¹ Nominal / Rated Heating² US Ton (nominal) Capacity (Btu/h) Performance Ducted / Non-Ducted Ducted / Non-Ducted Ducted / Non-Ducted Voltage Power Maximum Circuit Breaker (MCCB/ELB/ELCB) Minimum Circuit Ampacity (MCA) Indoor Units Total Capacity (%) 50 - 130% Of Outdoor Unit Capacity Maximum Indoor Unit Quantity Refrigerant Pipe Connections R410A Factory Charge (lbs.) Liquid X Suction (inches) Max. Distance - ODU to IDU (feet) Installation Limitation³ Vertical Separation ODU to IDU 4 (feet) Highest/Lowest IDU Total Refrigerant Pipe (feet) Sound Level Operating Temperatures Safety Certifications ETL & ETLc Intelligent logic to ensure proper operation within unit design limitations and operational parameters. Protection Devices High pressure sensor, low pressure sensor, over-voltage protection, compressor over- current protection, current transformer, fan motor voltage protection, fan motor thermal protection, overheat protection, phase detection protection, high voltage fuses Inverter PCB cooling done with liquid refrigerant to maintain optimal and safe operating temperatures. Model Number Outdoor unit tee (liquid and suction fittings, ≤ 461,000 Btu/h ) Top wind/hail guard (8 - 18 ton outdoor units) Left side wind/hail guard (6 - 16 ton outdoor units) Right side wind/hail guard (6 - 16 ton outdoor units) Rear wind/hail guard (8 - 16 ton outdoor units) Construction The unit shall be galvanized steel with a baked on powder coated finish. Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube. The aluminum fins of the heat exchanger shall have a protective coating. Salt spray test method: KS D 9502 (ASTM B117 equivalent) - the heat exchanger showed no unusual rust development to 2,000 hours. Controls The unit shall be operated via NASA Protocol with controls provided by Samsung The outdoor unit shall have a removable EEPROM that stores unit serial number, startup information, system settings, system tag/name, and other information. Controls shall integrate with a BMS system without additional interface modules Control wiring shall be 16 AWG X 2 shielded wire. Refrigerant System The compressors shall be Samsung hermetically sealed, inverter driven, direct vapor injected, DC scroll type with soft-start capability. Vapor injected compressors provide advanced low ambient heating performance. Refrigerant flow shall be controlled by EEV (electronic expansion valve) throughout the system. Subcooling devices in system maintain capacity at extreme system refrigerant pipe lengths and minimize refrigerant noise. Compatibility Only compatible with Samsung DVM S indoor units (AM****N***H***). Low ambient cooling hood (large chassis, 2 required) Other Features Asymmetrical scroll design with rotating compressor operation/priority (where applicable). Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered oil recovery cycles). Oil recovery operation shall not interrupt heating or cooling operation. Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic activation or manual activation (with MIM-B14). Heat pump mode selector switch External contact control interface module (operation and error output, night silent mode manual activation) Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by monitoring air resistance across the condenser coil during heating operation to determine defrost operation initiation to prevent unnecessary defrost cycles. 1 Nominal cooling capacities are based on: Indoor temperature: 80⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. Optional snow blowing logic to prevent snow accumulation on idle outdoor units 2 Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. Continuous operation while outdoor unit(s) change between heating and cooling modes (conditions apply). Other pipe restrictions and requirements exist. Please consult technical data book or installation manuals for full details regarding limitations and other requirements for vertical separation over 163 feet (outdoor to lowest indoor). 4 When outdoor unit is lower than indoor units, and vertical separation is greater than 131 feet, additional conditions apply. Please refer to supporting documents at www.SamsungHVAC.com Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or central control devices: DMS 2 (MIM-D00AN), DMS 2.5 (MIM-D01AUN), BACnet Gateway (MIM-B17N, MIM-B17BN), LON Gateway (MIM-B18N, MIM-B18BN). Energy savings options to reduce system energy consumption in heating mode when average indoor room temperatures are greater than average indoor set temperatures. Variable Refrigerant Flow (VRF) Multi-Split AC and

Open the catalog to page 1
SUBMITTAL AM288JXVAJH/AA - 2

2 of 3 SUBMITTAL AM288JXVAJH/AA Samsung DVM S Series, Heat Pump Condensing Unit Module Specifications Module Model Number Nominal / Rated Cooling¹ Nominal / Rated Heating² Capacity (Btu/h) Compressor Modulation Down to Voltage Power Maximum Circuit Breaker (MCCB/ELB/ELCB) Liquid X Suction (inches) Pipe Connections Minimum Circuit Ampacity (MCA) SCCR Shipping Weight Sound Level WXHXD Dimensions Max. External Static Pressure ¹ Nominal cooling capacities are based on: Indoor temperature: 80⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. ² Nominal heating capacities are based on: Indoor...

Open the catalog to page 2
SUBMITTAL AM288JXVAJH/AA - 3

SUBMITTAL AM288JXVAJH/AA Samsung DVM S Series, Heat Pump Condensing Unit AM144FXVAJH/AA Dimensional Drawing RIGHT SIDE LEFT SIDE 1 Gas refrigerant pipe opening 5 Power conduit opening (4 X Ø1 3/4") 2 Liquid refrigerant pipe opening 6 Communication conduit opening (8 X Ø7/8") 3 Power conduit opening (2 X Ø1 3/4") 7 Knock-out opening for refrigerant piping (7" X 3") 4 Communication conduit opening (2 X Ø1 3/8") 8 Anchor bolt hole (4 X Ø15/32")

Open the catalog to page 3