Catalog excerpts

Transport and Mailing Systems For transportation of diagnostic samples and blood products The complete product range for mailing and transport requirements Safe and compliant with transportation guidelines
Open the catalog to page 1
Transport Case Tested and approved Tested by the Federal Institute for Material Research and Testing (BAM) in Germany, the complete packaging system has been approved to comply with the requirements of P 650 Packaging Instructions for Class UN 3373 of the ADR and RID. Temperature control Cool storage packs (-18°C) placed in special bags combined with a layer of highly effective insulating foam maintain a stable specimen temperature. The insulating bag is made from a honeycomb-shaped fully synthetic insulating material and prevents specimens from freezing when they come into contact with the...
Open the catalog to page 2
For transport in accordance with P 650 Primary receptacle For the safe transportation of diagnostic liquid specimens, the primary receptacle must be designed to withstand, without leakage, an internal pressure difference of at least 95 kPa (0.95 Bar). It is important to only use primary receptacles with Sarstedt Transport Cases that are attested to remain safely sealed at this pressure difference. Secondary packaging Wide aperture flasks or plastic bags closed with a clip are available as a secondary packaging. The flask accommodates approximately 250 to 300 primary receptacles packed in...
Open the catalog to page 3
Mailing Box Tested and approved Tested by the Federal Institute for Material Research and Testing (BAM) in Germany, the complete packaging system has been approved to comply with the requirements of P650 Packaging Instructions for Class UN 3373 of the ADR, RID, ICAO and IATA. Economical The box offers a practical, cost-effective packaging solution. • Flexible The box is designed to accommodate all sizes of Sarstedt mailing containers. • Sample Protection 4 The box is available with integral restraints or with an enclosed foam bag for optimal stabilization and cushioning of the secondary...
Open the catalog to page 4
Packaging components Primary receptacle For the transportation of diagnostic liquid specimens, the primary receptacle or secondary container must be designed to withstand, without leakage, an internal pressure difference of at least 95 kPa (0.95 bar). The primary receptacle must be leakproof. Therefore, it is important to select the appropriate combination of primary receptacle and secondary container. Secondary container For the transport of diagnostic liquid specimens, the space between the primary receptacle and the secondary container must contain absorbent material. All Sarstedt...
Open the catalog to page 5
Ordering Information Transport Case with wide aperture flask Order No. 95.1715 Description Transport Case T 15 Secondary container: wide aperture flask incl. 1 Superabsorber pack, without cool storage pack L x W x H 395 x 395 x 435 mm Dry equipment weight: abt. 4,500 g Packaging 1/case Transport Case with plastic bag Order No. Description Packaging 95.1717 Transport Case B 17 Secondary container: plastic bag with clip incl. 1 Superabsorber pack, without cool storage pack L x W x H 395 x 395 x 435 mm Dry equipment weight: abt. 4,000 g 1/case 95.1717.003 Transport Case B 19 without lateral...
Open the catalog to page 6
Transport Case and Accessories Round mailing containers Fig. 1 Fig. 2 Order No. Fig. 3 *Order numbers for coloured caps are available on request. Description Packaging Fig. 2 250/case Special screw cap for Port-A-Cul Tube, neutral Separate absorbent liner Mailing container 85 x ø 30 mm, with absorbent liner, without screw cap 65.676 Standard screw cap, neutral* 78.684 Separate absorbent liner Mailing container 114 x ø 44 mm, with absorbent liner, without screw cap 250/case 65.678 Standard screw cap, neutral* 250/case 78.669 Fig. 3 Standard screw cap, neutral* 78.897 Fig. 3 65.679 78.892...
Open the catalog to page 7
Transport Systems For frozen transport in accordance with P 650 The Cool Transport Container can accommodate two sample tubes of 16.5 mm diameter and a maximum overall length of 107 mm, e.g. a 9 ml S-Monovette® or 13 ml screw cap tube 101 x 16.5 mm. After storing the container in a freezer, efficient cooling of the samples can be maintained over several hours (see illustration above). The container is not suited for samples that are not allowed to freeze. In combination with an appropriate transport box and absorbent liners (as shown below), the Cool Transport Container fully conforms to...
Open the catalog to page 8
Transport Systems For in-house sample transport Transport case for the safe in-house transport of diagnostic samples in hospitals and laboratories. The cases are designed to accommodate up to 100 sample tubes or swabs that can be transported in block racks. The system can be used in conjunction with the Sarstedt Safety-Tray and transport cases in accordance with P 650. Order No. Description Packaging 95.1720.011 Transport case 270 x 170 x 215 mm with transparent lid, suitable for 1 block rack D 17 for 50 samples 1 / case 95.1720 Transport case 360 x 310 x 275 mm with insert for 2 block...
Open the catalog to page 9
TRANS Control Safety Safe Patented locking devices on all sides prevent accidental opening of the TRANS Control elements/frames. Extra eyelets on the edges enable sealing of the elements/frames. TRANS Control is designed for the transport of temperature-sensitive blood products such as erythrocyte concentrates, thrombocyte concentrates or fresh frozen plasma. The products are kept at a constant temperature level during the entire transport time without active cooling. The temperature range is maintained by a refrigerant contained in the pre-cooled TRANS Control elements or frames....
Open the catalog to page 10
Transport of blood products Transport Optimal transport system Spacious box for cool transport complete with special insulation for optimal and safe short- and long-term transport of your blood products. Lockable! Shipping Temperature control Special thick-walled Neopor boxes can hold up to 3 TRANS Control elements. In combination with a transport container and depending on ambient temperatures, these boxes ensure a constant temperature levelfor up to 48 hours of transport. 11
Open the catalog to page 11All Sarstedt catalogs and technical brochures
-
Catalogue 2023
338 Pages
-
lumox® multiwell
2 Pages
-
GS 312
2 Pages
-
SARMIX® GM1
2 Pages
-
TRANS Control Transport box
2 Pages
-
Multi-Safe vario 2000
4 Pages
-
Medicine Cup
2 Pages
-
Incubator & Agitator
3 Pages
-
MegaBlock®
2 Pages
-
Urine Analysis
16 Pages
-
Urine Measuring System A06 W
4 Pages
-
TOPSWING
4 Pages
-
Blood Gas Analytics
3 Pages
-
Tube with saline solution
2 Pages
-
Lumox® x-well Technology
5 Pages
-
Gas Sampler
7 Pages
-
Transfusion devices
2 Pages
-
SAHARA-TSC
3 Pages
-
TRANSWAAG Pro
4 Pages
-
Single-Use Tourniquet
2 Pages
-
Microvette® APT
8 Pages
-
S-Monovette® POC Collect Kit
3 Pages
-
Systematic Workflow
17 Pages
-
HCTS 2000 MK2
3 Pages
-
PBM
3 Pages
-
Screw Cap Micro Tubes
16 Pages
-
REGANESTH® unoplex
2 Pages
-
Micro Tubes
16 Pages
-
Tourniquet application
3 Pages
-
Freezing tubes
3 Pages
-
IVARO Tube Handler
9 Pages
-
IsoFreeze® Rack
1 Pages
-
PCR & Molecular biology
21 Pages
-
White Multiply®-µStrips
2 Pages
-
Low Profile PCR items
1 Pages
-
NGS Library Preparation
2 Pages
-
Growth Surface References
20 Pages
-
Growth surfaces for cells
3 Pages
-
Automatic-Sarpette®
2 Pages
-
Micro-Needle
2 Pages
-
Blood Collection Systems
19 Pages
-
SMO S-Monovette® Organiser
2 Pages
-
12 ml Tube with conical base
1 Pages
-
S-Monovette® Hirudin 1.6 ml
2 Pages
-
SML-2 S-Monovette® Labeler
2 Pages
-
SML-3 S-Monovette® Labeler
2 Pages
-
IsoFreeze® PCR-Racks
1 Pages
-
Conversion of box packaging
2 Pages
-
PBM PatientBloodManagement
4 Pages
-
CATALOGUE GÉNÉRAL
109 Pages
-
THE SARSTEDT GROUP
9 Pages
-
White Multiply
2 Pages
-
REGANESTH
2 Pages
-
BL 1200
2 Pages
-
SML
2 Pages
-
V-Monovette urine
2 Pages
-
RadTag
2 Pages
-
Tube Sealers
4 Pages
-
Catheter quiver/Tube Holder
2 Pages
-
Transfusion systems
3 Pages
-
SAHARA-TSC
4 Pages
-
HAEM-o-TRANS
3 Pages
-
Pressure Line
4 Pages
-
SAHARA-III
4 Pages
-
ELISA Plates
3 Pages
-
HCTS2000 MK2
3 Pages
-
SMC 6 and SMC 6 plus
3 Pages
-
Single use tourniquets
2 Pages
-
Minivette® POCT
2 Pages
-
Sediplus
6 Pages
-
Celebration catalogue
220 Pages
-
Neutral Pipette Tips
1 Pages
-
2011 Systematic Workflow
32 Pages
-
Microbiology
12 Pages
-
flexiPERM®/quadriPERM®
2 Pages
-
miniPERM®
4 Pages
-
Cell and Tissue Culture
20 Pages
-
Sample Handling
4 Pages
-
Micro Tubes
4 Pages
-
Liquid Handling
40 Pages
-
Screw Cap Micro Tubes
8 Pages
-
Multi-Safe Disposal Box
16 Pages
-
Safety-Needle
52 Pages
-
S-Monovette® GlucoEXACT
40 Pages
-
Multiply® PCR Plates
7 Pages
-
UriSet 24
1 Pages
-
Urine Containers
1 Pages
-
Sediplus® S 100
1 Pages
-
S-Sedivette®
1 Pages
Archived catalogs
-
Forensic Swab
220 Pages